Closed Loop Control of Drives

Encyclopedia
04/29/2025

In a closed - loop system, the output of the system is fed back to the input, enabling the system to control the electrical drive and self - adjust its operation. Feedback loops in an electrical drive are incorporated to meet the following critical requirements:

  • Torque and Speed Enhancement: To boost the torque and speed performance of the system.

  • Steady - State Accuracy Improvement: To enhance the precision of the system during steady - state operation.

  • Protection: To safeguard the electrical drive components from potential damage.

The key components of a closed - loop system include the controller, converter, current limiter, and current sensor, among others. The converter plays a crucial role in converting variable frequency power to a fixed frequency and vice versa. The current limiter, on the other hand, functions to prevent the current from exceeding a pre - set maximum value. Below, we will explore the different types of closed - loop configurations.

Current Limit Control

This control scheme is designed to keep the converter and motor currents within a safe range during transient operations. The system features a current feedback loop integrated with a threshold logic circuit.

image.png

The logic circuit serves as a safeguard, protecting the system from excessive current. In the event that transient operations cause the current to rise above the pre-set maximum value, the feedback circuit is activated. It promptly takes corrective action, compelling the current to drop back below the maximum threshold. Once the current returns to normal levels, the feedback loop deactivates, resuming its standby state.

Closed-Loop Torque Control

Closed-loop torque control systems are widely employed in battery-powered vehicles, railway applications, and electric trains. The reference torque T^* is determined by the position of the accelerator pedal. The loop controller then works in tandem with the motor to ensure that the actual torque output closely follows the reference value T^*. By adjusting the pressure on the accelerator, the operator can effectively control the speed of the drive system, as the torque output directly influences the acceleration and speed of the vehicle or train.

image.png

Closed-Loop Speed Control

The block diagram of the closed - loop speed control system is illustrated in the figure below. This system features a nested control structure, with an inner control loop embedded within an outer speed loop. The primary function of the inner control loop is to regulate the motor current and torque, ensuring they remain within safe operating limits.

image.png

Closed - Loop Speed Control

Suppose there is a reference speed ωm∗ that generates a positive speed error Δω*m. This speed error is processed by a speed controller and then fed into a current limiter. Notably, the current limiter can become overloaded even in the presence of a minor speed error. The current limiter then sets the current for the inner current control loop. Subsequently, the drive system initiates acceleration. Once the drive speed matches the desired speed, the motor torque equals the load torque. This equilibrium causes the reference speed to decrease, resulting in a negative speed error.

When the current limiter reaches saturation, the drive enters a braking mode and begins to decelerate. Conversely, when the current limiter becomes desaturated, the drive smoothly transitions from the braking state back to the motoring mode.

Closed - Loop Speed Control of Multi - Motor Drives

In multi - motor drive systems, the overall load is distributed among multiple motors. Each section of the system is equipped with its own motor, which is primarily responsible for carrying the load specific to that section. Although the ratings of the motors vary depending on the type of load they serve, all the motors operate at the same speed. When the torque requirements of each individual motor are met by its respective driving mechanism, the driving shaft only needs to bear a relatively small synchronizing torque, facilitating coordinated operation of the multi - motor setup.

image.png

In a locomotive, due to varying degrees of wear and tear, the wheels do not revolve at a uniform speed. As a result, the driving speed of the locomotive fluctuates accordingly. Besides maintaining a consistent speed, it is equally crucial to ensure that torque is evenly distributed among the multiple motors. If this balance is not achieved, one motor may become overloaded while another remains underutilized. This imbalance ultimately leads to a situation where the rated torque of the entire locomotive is significantly lower than the cumulative torque ratings of the individual motors.

Encyclopedia

The Electricity Encyclopedia is dedicated to accelerating the dissemination and application of electricity knowledge and adding impetus to the development and innovation of the electricity industry.

Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
For users, when purchasing a 35kV new energy transformer, choosing between dry-type, mineral oil-filled, or vegetable oil-filled types involves multiple considerations. These include user habits, maintenance-free performance, safety and fire resistance, volume and weight, among others. However, cost differences are undoubtedly one of the most crucial factors.To illustrate the issue intuitively, this paper selects a three-level energy efficiency dual-winding new energy transformer with a rated ca
Ron
07/26/2025
What is the connection group of a transformer?
What is the connection group of a transformer?
Transformer Connection GroupThe connection group of a transformer refers to the phase difference between the primary and secondary voltages or currents. It is determined by the winding directions of the primary and secondary coils, the labeling of their start and end terminals, and the connection mode. Expressed in a clock-like format, there are 12 groups in total, numbered from 0 to 11.The DC method is commonly used to measure the transformer's connection group, mainly to verify whether the con
Vziman
07/26/2025
What is the sequence for powering down the transformer?
What is the sequence for powering down the transformer?
The sequence for shutting down a main transformer is as follows: when de-energizing, the load side should be shut down first, followed by the power supply side. For energizing operations, the reverse order applies: the power supply side is energized first, then the load side. This is because: Energizing from the power supply side to the load side makes it easier to identify the fault range and take prompt judgment and handling measures in case of a fault, preventing the fault from spreading or e
Rockwell
07/26/2025
What are the methods for switching operations of station transformers?
What are the methods for switching operations of station transformers?
Let's take an auxiliary power system with two station transformers as an example. When one station transformer needs to be out of service, there are two operation methods: non-interruptive power supply and instantaneous power interruption. Generally, the method of instantaneous power interruption on the low-voltage side is preferred.The operation method for instantaneous power interruption on the low-voltage side is as follows:Open the 380V power incoming circuit breaker of the corresponding sec
Vziman
07/26/2025
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!