What is the reason for using inverters instead of open circuit transformers in variable frequency drive applications?

Encyclopedia
11/07/2024

In variable frequency drive (VFD) applications, using an inverter instead of an open-circuit transformer (also known as a linear transformer) is preferred for several reasons. Here are the main reasons:

1. Adjustable Output Frequency

Inverter: An inverter can generate AC power with a variable frequency, which is the core function of a VFD. By adjusting the output frequency, the speed and torque of the motor can be controlled precisely.

Open-Circuit Transformer: An open-circuit transformer can only provide a fixed frequency output, typically matching the grid frequency (50Hz or 60Hz), and cannot adjust the frequency.

2. Higher Efficiency

Inverter: Inverters operate using efficient switching devices (such as IGBTs) and can achieve high efficiency, often exceeding 95%.

Open-Circuit Transformer: Open-circuit transformers experience iron losses and copper losses, particularly at light or no load, resulting in lower efficiency.

3. Lower Inrush Current

Inverter: Inverters can control the inrush current during motor startup, avoiding large current spikes. This helps extend the life of the motor and reduces the impact on the power grid.

Open-Circuit Transformer: Open-circuit transformers cannot control the inrush current, leading to significant startup currents that can cause voltage drops in the grid and interfere with other equipment.

4. Fast Dynamic Response

Inverter: Inverters have fast dynamic response capabilities, allowing them to quickly adjust the output to adapt to load changes. This is crucial for applications requiring rapid response.

Open-Circuit Transformer: Open-circuit transformers have slower dynamic responses and cannot quickly adapt to load changes.

5. Rich Protection Functions

Inverter: Inverters typically come equipped with multiple protection functions, such as overload protection, short-circuit protection, and overheat protection, ensuring safe operation of the system.

Open-Circuit Transformer: Open-circuit transformers have limited protection functions and often require external protection devices.

6. Harmonic Suppression

Inverter: Modern inverters often include harmonic filters that effectively suppress harmonics, reducing grid pollution.

Open-Circuit Transformer: Open-circuit transformers cannot effectively suppress harmonics, potentially degrading grid quality.

7. Flexibility and Programmability

Inverter: Inverters offer high flexibility and programmability, allowing for complex functions to be implemented through parameter settings and programming, such as multi-speed control and PID regulation.

Open-Circuit Transformer: Open-circuit transformers have limited functionality and cannot achieve complex control and regulation.

8. Size and Weight

Inverter: Inverters are typically smaller in size and lighter in weight, making them easier to install and maintain.

Open-Circuit Transformer: Open-circuit transformers are larger in size and heavier, making installation and handling more difficult.

9. Cost-Effectiveness

Inverter: Although the initial investment may be higher, the high efficiency and energy savings of inverters can lead to significant cost savings over the long term, providing good cost-effectiveness.

Open-Circuit Transformer: Open-circuit transformers have a lower initial cost, but their lower efficiency and higher maintenance costs result in higher long-term operating costs.

Summary

In VFD applications, inverters offer numerous advantages over open-circuit transformers, including adjustable output frequency, high efficiency, low inrush current, fast dynamic response, rich protection functions, harmonic suppression, flexibility and programmability, smaller size and weight, and good cost-effectiveness. These advantages make inverters the preferred choice for VFD applications.

Encyclopedia

The Electricity Encyclopedia is dedicated to accelerating the dissemination and application of electricity knowledge and adding impetus to the development and innovation of the electricity industry.

Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
For users, when purchasing a 35kV new energy transformer, choosing between dry-type, mineral oil-filled, or vegetable oil-filled types involves multiple considerations. These include user habits, maintenance-free performance, safety and fire resistance, volume and weight, among others. However, cost differences are undoubtedly one of the most crucial factors.To illustrate the issue intuitively, this paper selects a three-level energy efficiency dual-winding new energy transformer with a rated ca
Ron
07/26/2025
What is the connection group of a transformer?
What is the connection group of a transformer?
Transformer Connection GroupThe connection group of a transformer refers to the phase difference between the primary and secondary voltages or currents. It is determined by the winding directions of the primary and secondary coils, the labeling of their start and end terminals, and the connection mode. Expressed in a clock-like format, there are 12 groups in total, numbered from 0 to 11.The DC method is commonly used to measure the transformer's connection group, mainly to verify whether the con
Vziman
07/26/2025
What is the sequence for powering down the transformer?
What is the sequence for powering down the transformer?
The sequence for shutting down a main transformer is as follows: when de-energizing, the load side should be shut down first, followed by the power supply side. For energizing operations, the reverse order applies: the power supply side is energized first, then the load side. This is because: Energizing from the power supply side to the load side makes it easier to identify the fault range and take prompt judgment and handling measures in case of a fault, preventing the fault from spreading or e
Rockwell
07/26/2025
What are the methods for switching operations of station transformers?
What are the methods for switching operations of station transformers?
Let's take an auxiliary power system with two station transformers as an example. When one station transformer needs to be out of service, there are two operation methods: non-interruptive power supply and instantaneous power interruption. Generally, the method of instantaneous power interruption on the low-voltage side is preferred.The operation method for instantaneous power interruption on the low-voltage side is as follows:Open the 380V power incoming circuit breaker of the corresponding sec
Vziman
07/26/2025
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!