What are the methods for identifying whether a transformer has solid insulated windings or paper-oil insulated windings?

Encyclopedia
Encyclopedia
Field: Encyclopedia
0
China

Identifying whether transformer windings use solid insulation or paper-in-oil insulation involves several methods, including physical inspection, electrical testing, and other analytical approaches. Here are some common methods to distinguish between the two types of insulation:

Physical Inspection 

1. Visual Inspection

  • Inspect Winding Materials: Solid insulation transformers typically use polymers (such as epoxy resin, polyester film, etc.) as insulating materials, whereas paper-in-oil insulation transformers use impregnated paper and oil.

  • Disassembly Inspection : If feasible, disassembling the transformer can allow for an examination of the internal winding insulation materials.

2. Weight Comparison 

Weight Difference: Since paper-in-oil insulation transformers contain a significant amount of insulating oil, they tend to be heavier than solid insulation transformers of the same capacity.

Electrical Testing 

1. Dielectric Constant Measurement 

Dielectric Constant : Different insulating materials have different dielectric constants. By measuring the dielectric constant of the windings, one can infer the type of insulation material. Solid insulations (like epoxy resin) have different dielectric constants compared to paper-in-oil insulations.

2. Withstand Voltage Test 

Withstand Voltage Performance : The withstand voltage performance of solid insulation and paper-in-oil insulation can vary. Solid insulation usually exhibits higher withstand voltage performance, while paper-in-oil insulation might perform poorly under high temperatures and humidity.

3. Leakage Current Measurement 

Leakage Current : Measuring the leakage current of the windings under applied voltage can reveal differences. Solid insulations generally show lower leakage currents.

Other Analytical Methods 

1. Thermographic Inspection 

Temperature Distribution : Using infrared thermography to inspect the temperature distribution of the transformer during operation can help identify the type of insulation based on thermal patterns. Solid insulation and paper-in-oil insulation exhibit different heating profiles.

2. Chemical Composition Analysis 

Sample Analysis : Sampling and chemically analyzing the contents of a transformer suspected to contain insulating oil can confirm the presence of paper-in-oil insulation.

3. Acoustic Inspection

Sound Characteristics: Auditory or acoustic instruments can detect the sound characteristics of the transformer during operation. Different types of insulations might produce distinct sound patterns.

Comprehensive Evaluation 

Combine Multiple Methods: In practice, multiple methods are typically combined to make a comprehensive determination. A single method might not be sufficient for accurate identification, so multiple testing techniques are recommended to cross-verify results.

Considerations

  • Professional Skills: Electrical tests and analyses require professional knowledge and skills to ensure accurate results and safety.

  • Safety Precautions: When performing disassembly or other operations, appropriate safety measures should be taken to avoid injury or damage to the equipment.

Summary

Identifying whether transformer windings use solid insulation or paper-in-oil insulation can be achieved through physical inspection, electrical testing, and other analytical methods. In practice, combining multiple methods is advisable, and safety precautions must be observed during testing. If specific testing or analysis is needed, consulting with professional electrical engineers or technicians is recommended.

If you have any further questions or need additional information, please feel free to ask!



Give a tip and encourage the author!
Recommended
How to Identify Internal Faults in a Transformer?
How to Identify Internal Faults in a Transformer?
Measure DC resistance: Use a bridge to measure the DC resistance of each high- and low-voltage winding. Check whether the resistance values among phases are balanced and consistent with the manufacturer’s original data. If phase resistance cannot be measured directly, line resistance may be measured instead. The DC resistance values can indicate whether the windings are intact, whether there are short circuits or open circuits, and whether the contact resistance of the tap changer is normal. If
Felix Spark
11/04/2025
What are the requirements for inspecting and maintaining a transformer's no-load tap changer?
What are the requirements for inspecting and maintaining a transformer's no-load tap changer?
The tap changer operating handle shall be equipped with a protective cover. The flange at the handle shall be well sealed with no oil leakage. Locking screws shall securely fasten both the handle and the drive mechanism, and the handle rotation shall be smooth without binding. The position indicator on the handle shall be clear, accurate, and consistent with the tap voltage regulation range of the winding. Limit stops shall be provided at both extreme positions. The insulating cylinder of the t
Leon
11/04/2025
How to Overhaul a Transformer Conservator (Oil Pillow)?
How to Overhaul a Transformer Conservator (Oil Pillow)?
Overhaul Items for Transformer Conservator:1. Ordinary-Type Conservator Remove the end covers on both sides of the conservator, clean rust and oil deposits from inner and outer surfaces, then apply insulating varnish to the inner wall and paint to the outer wall; Clean components such as the dirt collector, oil level gauge, and oil plug; Check that the connecting pipe between the explosion-proof device and the conservator is unobstructed; Replace all sealing gaskets to ensure good sealing with n
Felix Spark
11/04/2025
Why is it difficult to increase the voltage level?
Why is it difficult to increase the voltage level?
The solid-state transformer (SST), also known as a power electronic transformer (PET), uses voltage level as a key indicator of its technological maturity and application scenarios. Currently, SSTs have reached voltage levels of 10 kV and 35 kV on the medium-voltage distribution side, while on the high-voltage transmission side, they remain in the stage of laboratory research and prototype validation. The table below clearly illustrates the current status of voltage levels across different appli
Echo
11/03/2025
Related Products
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.