What is the classification of a transformer?

Encyclopedia
10/26/2024

Classification of Transformers

A transformer is a device that can change the alternating voltage and is widely used in power systems, industrial equipment, and household appliances. Transformers can be divided into various types according to different standards. The following are the main classification methods of transformers and their specific types:

Classified by use

  1. Power Transformer: Used for stepping up and down voltage in power distribution systems.

  2. Instrument Transformers: Such as voltage transformers and current transformers, used for measuring instruments and relay protection devices.

  3. Test Transformer: Capable of generating high voltage for conducting high-voltage tests on electrical equipment.

  4. Special Transformer: Such as electric furnace transformer, rectifier transformer, regulating transformer, capacitor transformer, phase shift transformer, etc.

Classification by the number of phases

  1. Single-phase Transformer: Used for single-phase loads and three-phase transformer banks.

  2. Three-phase Transformer: Used for stepping up and down voltage in three-phase systems.

Classified by cooling method

  1. Dry-type Transformer: Relying on air convection for natural cooling or with the addition of fans for cooling, these transformers are commonly used in high-rise buildings, local lighting, and other low-capacity transformer applications.

  2. Oil-immersed Transformer: relies on oil as the cooling medium, such as oil self-cooling, oil air-cooling, oil water-cooling, and forced oil circulation.

Classification by winding form

  1. Two-winding Transformer: Used to connect two voltage levels in a power system.

  2. Three-winding Transformer: Typically used in regional substations of power systems to connect three voltage levels.

  3. Autotransformer: A transformer in which the primary and secondary windings are on the same winding.

Classification by Core Type

  1. Core Transformer: A power transformer used for high voltage.

  2. Shell-type Transformer: A special transformer designed for high current applications, such as electric furnace transformers and welding transformers; or used as power transformers for electronic equipment, TVs, and radios.

  3. Amorphous Alloy Transformer: Amorphous alloy iron core transformers are made with new magnetic materials, reducing no-load current by about 80%. They are currently the most energy-efficient distribution transformers and are especially suitable for areas with low load rates such as rural power grids and developing regions.

The above is the main classification method of transformers and their specific types. Each type of transformer has its own specific application scenarios and technical features. Choosing the right transformer is essential for ensuring the stable operation of the power system.

Encyclopedia

The Electricity Encyclopedia is dedicated to accelerating the dissemination and application of electricity knowledge and adding impetus to the development and innovation of the electricity industry.

Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
For users, when purchasing a 35kV new energy transformer, choosing between dry-type, mineral oil-filled, or vegetable oil-filled types involves multiple considerations. These include user habits, maintenance-free performance, safety and fire resistance, volume and weight, among others. However, cost differences are undoubtedly one of the most crucial factors.To illustrate the issue intuitively, this paper selects a three-level energy efficiency dual-winding new energy transformer with a rated ca
Ron
07/26/2025
What is the connection group of a transformer?
What is the connection group of a transformer?
Transformer Connection GroupThe connection group of a transformer refers to the phase difference between the primary and secondary voltages or currents. It is determined by the winding directions of the primary and secondary coils, the labeling of their start and end terminals, and the connection mode. Expressed in a clock-like format, there are 12 groups in total, numbered from 0 to 11.The DC method is commonly used to measure the transformer's connection group, mainly to verify whether the con
Vziman
07/26/2025
What is the sequence for powering down the transformer?
What is the sequence for powering down the transformer?
The sequence for shutting down a main transformer is as follows: when de-energizing, the load side should be shut down first, followed by the power supply side. For energizing operations, the reverse order applies: the power supply side is energized first, then the load side. This is because: Energizing from the power supply side to the load side makes it easier to identify the fault range and take prompt judgment and handling measures in case of a fault, preventing the fault from spreading or e
Rockwell
07/26/2025
What are the methods for switching operations of station transformers?
What are the methods for switching operations of station transformers?
Let's take an auxiliary power system with two station transformers as an example. When one station transformer needs to be out of service, there are two operation methods: non-interruptive power supply and instantaneous power interruption. Generally, the method of instantaneous power interruption on the low-voltage side is preferred.The operation method for instantaneous power interruption on the low-voltage side is as follows:Open the 380V power incoming circuit breaker of the corresponding sec
Vziman
07/26/2025
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!