• 10kV 24kV 35kV 69kV Compact Power Distribution Unit Pad Mounted Capacitor Bank Prefabricated Outdoor Substation
10kV 24kV 35kV 69kV Compact Power Distribution Unit Pad Mounted Capacitor Bank Prefabricated Outdoor Substation
discuss personally
Model
ZGS-33
ZGS-24
ZGS-11
Basic info
Brand ROCKWILL
Model NO. 10kV 24kV 35kV 69kV Compact Power Distribution Unit Pad Mounted Capacitor Bank Prefabricated Outdoor Substation
Rated voltage 33kV
Rated frequency 50/60Hz
Series ZGS
Product Detail

Descripton

ZGS installed substation is made of American box changed. The product as the cable of distribution network power supply unit, high voltage control, protection, substation, as well as the power distribution equipment in one of the sets of pre products, widely used in urban and rural distribution network.The product will be high voltage load switch, high voltage fuse in the transformer oil, with a total of two kinds of structural forms of the transformer box body or box. 
Tank using full sealed structure, with the oil temperature gauge, oil level gauge, pressure gauge, pressure release valve, drain valve etc. element to monitoring transformer operation status. The product is divided into ring network, terminal type and power supply mode. In order to make this product is more suitable for the actual requirements of the power grid in China, company and push the plug type fuse, fuse fuse does not affect the performance of transformer oil. According to the low voltage feed to the complexity of the, ZBW-12/0.4 products points to strengthen the standard type, type and comprehensive type three shell form, users and design units in the selection. Do more flexible and more economic.

Product Features and Structure

  • Application and Structure: The ZBW prefabricated substation, also known as an "American box-type substation," uses a fully sealed structure to ensure environmental resilience. The transformer section integrates a high-voltage load switch and high-voltage fuse in transformer oil, providing reliable protection without compromising transformer oil quality.
  • High-Voltage Components: Equipped with a high-voltage load switch, high-voltage fuses, and connection options for both ring network and terminal configurations, the substation meets diverse distribution network requirements with flexibility and safety.
  • Monitoring and Maintenance: The substation tank includes indicators for oil temperature, oil level, pressure, and pressure relief, ensuring effective monitoring of transformer status.
  • Shell Construction: The robust shell is manufactured from high-strength materials with anti-corrosion treatment, providing protection against harsh weather. This makes the substation ideal for outdoor installation with long service life.

Technical Parameters

Technical Specifications

  • Rated Voltage: 10/0.4 kV (high and low voltage sides)
  • High-Voltage Side Rated Voltage: 10kV or 12kV
  • Low-Voltage Side Rated Voltage: 0.4kV
  • Frequency: 50 Hz
  • Protection Grade: IP3X
  • Noise Level: ≤50 dB

The substation supports various high-voltage rated withstand voltages and impulse withstand levels for increased safety and reliability in the field.

Environmental Suitability

The ZBW prefabricated substation is designed to operate effectively in environments with temperatures ranging from -30°C to +40°C, altitudes up to 1000m, and humidity up to 95%. Its construction is highly resistant to corrosion, seismic activity, and other environmental stresses.

Construction Requirements

The foundation of the substation is designed to meet a minimum load-bearing capacity of 100 kPa and includes a drainage system and protective grounding with grounding resistance ≤ 4 ohms.
(Updated2025.March.5th)

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
For users, when purchasing a 35kV new energy transformer, choosing between dry-type, mineral oil-filled, or vegetable oil-filled types involves multiple considerations. These include user habits, maintenance-free performance, safety and fire resistance, volume and weight, among others. However, cost differences are undoubtedly one of the most crucial factors.To illustrate the issue intuitively, this paper selects a three-level energy efficiency dual-winding new energy transformer with a rated ca
Ron
07/26/2025
What is the connection group of a transformer?
What is the connection group of a transformer?
Transformer Connection GroupThe connection group of a transformer refers to the phase difference between the primary and secondary voltages or currents. It is determined by the winding directions of the primary and secondary coils, the labeling of their start and end terminals, and the connection mode. Expressed in a clock-like format, there are 12 groups in total, numbered from 0 to 11.The DC method is commonly used to measure the transformer's connection group, mainly to verify whether the con
Vziman
07/26/2025
Working Voltage in Power System
Working Voltage in Power System
Working VoltageThe term "working voltage" refers to the maximum voltage that a device can withstand without sustaining damage or burning out, while ensuring the reliability, safety, and proper operation of both the device and associated circuits.For long-distance power transmission, the use of high voltage is advantageous. In AC systems, maintaining a load power factor as close to unity as possible is also economically necessary. Practically, heavy currents are more challenging to handle than hi
Encyclopedia
07/26/2025
What is Steady State Stability in Power System?
What is Steady State Stability in Power System?
Definition of Steady State StabilitySteady state stability is defined as the capability of an electric power system to sustain its initial operating condition following a small disturbance, or to converge to a state closely approximating the initial condition when the disturbance persists. This concept holds critical significance in power system planning and design, the development of specialized automatic control devices, the commissioning of new system components, and the adjustment of operati
Edwiin
07/26/2025
What is the sequence for powering down the transformer?
What is the sequence for powering down the transformer?
The sequence for shutting down a main transformer is as follows: when de-energizing, the load side should be shut down first, followed by the power supply side. For energizing operations, the reverse order applies: the power supply side is energized first, then the load side. This is because: Energizing from the power supply side to the load side makes it easier to identify the fault range and take prompt judgment and handling measures in case of a fault, preventing the fault from spreading or e
Rockwell
07/26/2025
What are the methods for switching operations of station transformers?
What are the methods for switching operations of station transformers?
Let's take an auxiliary power system with two station transformers as an example. When one station transformer needs to be out of service, there are two operation methods: non-interruptive power supply and instantaneous power interruption. Generally, the method of instantaneous power interruption on the low-voltage side is preferred.The operation method for instantaneous power interruption on the low-voltage side is as follows:Open the 380V power incoming circuit breaker of the corresponding sec
Vziman
07/26/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!