• 11kV Three-Phase Oil-Immersed Grounding Transformer
11kV Three-Phase Oil-Immersed Grounding Transformer
discuss personally
Model
JDS-500-11
Basic info
Brand Rockwell
Model NO. 11kV Three-Phase Oil-Immersed Grounding Transformer
Rated frequency 50/60Hz
Rated capacity 500kVA
Series JDS
Product Detail

Description

Earthing transformers are classified as standard reactors. An earthing transformer (neutral coupler) is a three-phase transformer connected to the power system to provide a neutral connection for earthing, either directly or via impedance. The earthing transformers may, in addition, supply a local auxiliary load.

During single-phase faults, the reactor limits the fault current in the neutral, and the restoration of the power line is improved. According to the IEC 60076-6 standard, the neutral-earthing reactor is connected between the neutral of a power system and the earth to limit the line to earth current under system earth fault conditions to the desired value. 

The earthing transformer creates a neutral point for a network. ZN connection is usually applied. Z connection provides linear and specified zero sequence impedance. YN + d can also be applied. 

Features

Functional Uniqueness:

  • Constructing an Artificial Neutral Point: Provides a reliable neutral point connection for systems with ungrounded or high-impedance grounded neutrals (such as IT systems and resonant grounded systems).

  • Grounding Path Management: The neutral point can be directly grounded or grounded via a reactor/resistor, precisely limiting single-phase ground fault current (in line with IEC 60076-6).

Fault Current Control:

  • Suppressing Fault Current: Limits the ground fault current to a safe valuev by connecting a neutral reactor in series, preventing equipment damage.

  • Accelerating System Recovery: Reducing the magnitude of the fault current helps the arc self-extinguish, shortens power outage duration, and improves power supply continuity.

Winding Connection Methods:

  • ZN Type (Zigzag Connection): A mainstream design that provides linear zero-sequence impedance, with strong magnetic circuit balance and anti-saturation capability.

  • YN+d (Star + Delta): The secondary delta winding can supply auxiliary loads (doubling as a station service transformer function).

  • Controllable Zero-Sequence Impedance: Impedance values can be customized to ensure precise matching with the system protection strategy.Safety and Standard Compliance:

  • Following IEC 60076-6: Regulates the temperature rise, insulation, and short-circuit withstand capability of neutral reactors.

  • Overvoltage Suppression: Limits transient overvoltages caused by ground faults, protecting equipment insulation.

Main Technical Parameters

Know your supplier
Rockwell
Wenzhou Rockwell Transformer Co., Ltd. It is a high - tech enterprise integrating R & D, production, sales, and service. It focuses on the manufacturing of power transformers and supporting equipment, and is committed to providing efficient, reliable, and energy - saving power transmission and distribution solutions for global customers. We can offer: •Distribution transformers and substations •Outdoor switchgears and breakers(recloser) •Switchgears and it’s components (GIS, RMU, VCB, SF6 CB) Market and Service: We always take customers as the orientation and provide customized services according to their requirements. Our products are exported to the Middle East, Africa, Northern Europe, South America, and many other countries and regions. Drive the future of electricity with technological innovation and become a leading global supplier of intelligent power equipment.
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$100000000
Professional Experience
12 years
Workplace
60000m²
占位
占位
Related Products
Related Knowledges
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
For users, when purchasing a 35kV new energy transformer, choosing between dry-type, mineral oil-filled, or vegetable oil-filled types involves multiple considerations. These include user habits, maintenance-free performance, safety and fire resistance, volume and weight, among others. However, cost differences are undoubtedly one of the most crucial factors.To illustrate the issue intuitively, this paper selects a three-level energy efficiency dual-winding new energy transformer with a rated ca
Ron
07/26/2025
What is the connection group of a transformer?
What is the connection group of a transformer?
Transformer Connection GroupThe connection group of a transformer refers to the phase difference between the primary and secondary voltages or currents. It is determined by the winding directions of the primary and secondary coils, the labeling of their start and end terminals, and the connection mode. Expressed in a clock-like format, there are 12 groups in total, numbered from 0 to 11.The DC method is commonly used to measure the transformer's connection group, mainly to verify whether the con
Vziman
07/26/2025
Working Voltage in Power System
Working Voltage in Power System
Working VoltageThe term "working voltage" refers to the maximum voltage that a device can withstand without sustaining damage or burning out, while ensuring the reliability, safety, and proper operation of both the device and associated circuits.For long-distance power transmission, the use of high voltage is advantageous. In AC systems, maintaining a load power factor as close to unity as possible is also economically necessary. Practically, heavy currents are more challenging to handle than hi
Encyclopedia
07/26/2025
What is Steady State Stability in Power System?
What is Steady State Stability in Power System?
Definition of Steady State StabilitySteady state stability is defined as the capability of an electric power system to sustain its initial operating condition following a small disturbance, or to converge to a state closely approximating the initial condition when the disturbance persists. This concept holds critical significance in power system planning and design, the development of specialized automatic control devices, the commissioning of new system components, and the adjustment of operati
Edwiin
07/26/2025
What is the sequence for powering down the transformer?
What is the sequence for powering down the transformer?
The sequence for shutting down a main transformer is as follows: when de-energizing, the load side should be shut down first, followed by the power supply side. For energizing operations, the reverse order applies: the power supply side is energized first, then the load side. This is because: Energizing from the power supply side to the load side makes it easier to identify the fault range and take prompt judgment and handling measures in case of a fault, preventing the fault from spreading or e
Rockwell
07/26/2025
What are the methods for switching operations of station transformers?
What are the methods for switching operations of station transformers?
Let's take an auxiliary power system with two station transformers as an example. When one station transformer needs to be out of service, there are two operation methods: non-interruptive power supply and instantaneous power interruption. Generally, the method of instantaneous power interruption on the low-voltage side is preferred.The operation method for instantaneous power interruption on the low-voltage side is as follows:Open the 380V power incoming circuit breaker of the corresponding sec
Vziman
07/26/2025
×
Inquiry
Download