• 2000KVA 1600KVA 11KV 13.2KV 13.8KV Pad-Mounted Transformers
2000KVA 1600KVA 11KV 13.2KV 13.8KV Pad-Mounted Transformers
discuss personally
Model
ZGS-11
Basic info
Brand ROCKWILL
Model NO. 2000KVA 1600KVA 11KV 13.2KV 13.8KV Pad-Mounted Transformers
Rated voltage 11kV
Series ZGS
Product Detail

Product Description
Rockwill's pad-mounted transformers are engineered for superior performance across a comprehensive power range from 75 kVA to 5000 kVA. Our units incorporate integrated high-voltage fuses and switches for complete circuit protection, featuring innovative elbow connector technology that enables safe live-line connections and maintenance operations using hot sticks. Designed for reliability, all transformers undergo rigorous testing and comply with leading industry standards including CSA, ANSI C57, DOE, and IEEE requirements.

The ZGS11-H(Z) series represents our next-generation combined transformer solution, offering an optimized compact design that delivers exceptional space efficiency without compromising performance. These units are specifically engineered for urban load center applications, providing enhanced power distribution efficiency and improved supply quality.

Key Features & Benefits

Advanced Safety System

  • Fully sealed, oil-filled construction with complete insulation

  • Integrated high-voltage protection with visible break switches

  • Tamper-resistant enclosure with secure locking mechanism

Network Flexibility

  • Dual-mode operation for both loop and radial feed configurations

  • Plug-and-play cable connection system

  • Compatible with SCADA and smart grid applications

Premium Performance

  • Ultra-low no-load and load losses (meets DOE 2016 efficiency standards)

  • Acoustic noise levels below NEMA standards

  • 150% overload capacity for emergency operation

Robust Construction

  • Military-grade corrosion protection (ASTM B117 salt spray tested)

  • -40°C to +50°C operational temperature range

  • Seismic-rated design (Zone 4 compliance)

Smart Ready Design

  • Built-in monitoring points for IoT integration

  • Optional remote temperature and load monitoring

  • Predictive maintenance capability

Typical Applications
• Urban distribution network upgrades and expansions
• High-density residential and commercial developments
• Critical infrastructure power systems (hospitals, data centers)
• Industrial parks and manufacturing facilities
• Renewable energy interconnection points

Parameters

Specification

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Research on Cable Laying and Wiring Construction Technology of Photovoltaic Power Station
Research on Cable Laying and Wiring Construction Technology of Photovoltaic Power Station
1 Research on Cable Laying and Wiring Construction Technology of Photovoltaic Power Station1.1 Data CollectionBefore constructing the BIM model for cable laying, it is necessary to deeply master the detailed parameters of the involved equipment specifications, materials used in construction, and site conditions, aiming to improve the accuracy of model construction. To ensure that the BIM model can accurately reflect the actual situation of the construction site, the core lies in accurately colle
Echo
07/29/2025
Cable Detection and Analysis of Integrated Wiring System in Intelligent Buildings
Cable Detection and Analysis of Integrated Wiring System in Intelligent Buildings
The integrated wiring system of intelligent buildings, as the core carrier of information transmission, functions like a "nervous system." It connects signals such as voice, data, and images, enabling device interconnection and efficient information transmission. Cable detection is a key link to ensure system performance and information security, focusing on index detection, problem troubleshooting, and response measures.1. Core Cable Detection Indicators1.1 Appearance and Identification Verific
Oliver Watts
07/29/2025
What are the key points for quality control in the installation of communication cables in protective spaces?
What are the key points for quality control in the installation of communication cables in protective spaces?
In the context of deep integration of informatization and intelligence, protective spaces, as core carriers of critical communication systems, their stability and safety directly impact information transmission reliability and infrastructure operational efficiency. Thus, analyzing core difficulties (environmental adaptability matching, electromagnetic compatibility design, construction precision control) in communication cable installation in protective spaces holds significant engineering value
James
07/29/2025
What are the basic processes and key points in transformer simulation design?
What are the basic processes and key points in transformer simulation design?
1 IntroductionWhether using any finite element analysis software (such as COMSOL, Infolytica, or Ansys) for transformer simulation analysis—whether focusing on electric field, magnetic field, flow field, mechanical field, or acoustic field—the basic process is roughly the same. A true understanding of the key points in each process is the foundation for the success of the simulation analysis and the reliability of the final results.2 Basic Simulation ProcessA scientific and complete
Ron
07/29/2025
Sharing of Transformer Concepts and Terminology
Sharing of Transformer Concepts and Terminology
Sharing of Transformer Concepts and TerminologyThe zero-mode impedance of a load is infinite, and its line-mode impedance is also extremely large, approximately 100 times that of the line-mode impedance of the line.The capacitance to ground of a cable is 25-50 times that of an overhead line.The free oscillation frequency of transient capacitive current: 300-1500Hz for overhead lines and 1500-3000Hz for cables.Performance requirements for an external grounding transformer: Under normal power supp
Edwiin
07/28/2025
What is a traveling wave?
What is a traveling wave?
Traveling Waves on LinesA traveling wave on a line refers to a voltage or current wave propagating along the line; it is also defined as a voltage or current signal traveling along a conductor.Steady-state traveling wave: A traveling wave propagating along the line during the normal operation of a system, generated by the system's power supply.Transient traveling wave: A suddenly occurring traveling wave during system operation, caused by ground faults, short-circuit faults, wire breakages, swit
Leon
07/28/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!