484MVA/500kV GSU Generator Step-Up Transformer Nuclear Power Plant(Transformer for generation)

  • 484MVA/500kV GSU Generator Step-Up Transformer Nuclear Power Plant(Transformer for generation)

Key attributes

Brand ROCKWILL
Model NO. 484MVA/500kV GSU Generator Step-Up Transformer Nuclear Power Plant(Transformer for generation)
Rated frequency 50/60Hz
Series GSU

Product descriptions from the supplier

Description

Description

The GSU (Generator Step-Up) Transformer plays a critical role in nuclear power plants as a core electrical device connecting nuclear generators to the transmission grid. Within the plant, nuclear reactors produce massive thermal energy, which is converted into high-temperature, high-pressure steam via steam generators to drive turbine generators and generate electricity. At this stage, the generator outputs medium-low voltage alternating current (typically 10–20kV). The primary function of the GSU transformer is to significantly boost this voltage to levels such as 110kV, 220kV, or higher, meeting the demands of long-distance, large-capacity power transmission, reducing energy loss during transmission, and enabling efficient integration of nuclear power into the grid. Its operational status directly impacts the stability and reliability of nuclear power output, as well as the safe and stable operation of the entire power system, making it a key hub for ensuring continuous and stable power supply from nuclear plants.

  • 1-Ph 484MVA/500kV

Features

  • Ultra-High Reliability and Stability: Nuclear power plants have extremely stringent operational requirements. GSU transformers use top-quality high-permeability silicon steel sheets for cores and high-purity oxygen-free copper for windings, combined with advanced manufacturing processes and insulation technologies. This ensures reliable and stable operation under long-term high loads and continuous service, minimizing failure risks and reducing disruptions to nuclear power generation. They are also equipped with redundant protection and monitoring systems, such as multiple relay protection devices that real-time monitor current, voltage, and temperature. These systems act quickly to cut off circuits in case of abnormalities, preventing fault escalation. Additionally, smart sensors continuously track equipment performance, providing data support for preventive maintenance to keep the device in optimal condition.

  • Strong Short-Circuit Resistance: The internal power grid of nuclear plants is complex, and short-circuit faults may occur under abnormal conditions, generating powerful short-circuit currents and electromagnetic forces. GSU transformers feature specially wound windings to enhance mechanical strength and stability between windings, enabling them to effectively withstand the impact of strong electromagnetic forces during short circuits. This maintains structural integrity, ensures transformer safety, and avoids severe consequences such as equipment damage or even nuclear plant shutdowns caused by short circuits.

  • Adaptability to Harsh Environments: Nuclear power plants have complex internal environments with factors like radiation, high temperatures, high humidity, and chemical corrosion. GSU transformers are designed with enclosures featuring excellent shielding performance to effectively block radiation and protect internal electrical components. They use high-temperature-resistant, moisture-resistant, and corrosion-resistant insulation materials and protective coatings, ensuring stable insulation performance in high-temperature and high-humidity environments. This prevents issues like insulation aging or short circuits caused by environmental factors, guaranteeing long-term normal operation in harsh nuclear plant conditions.

  • Large Capacity and High-Voltage Compatibility: As nuclear power plant generation capacity continues to increase, demands for GSU transformer capacity and voltage levels have risen. These transformers typically offer capacities of several hundred MVA or higher, with voltage levels that match grid connection requirements—stepping up from tens of kV to 110kV, 220kV, or higher. This enables efficient large-scale transmission of nuclear power, meeting society’s massive electricity needs.

  • Low Loss and Energy Efficiency: Amid growing emphasis on energy utilization and environmental protection, GSU transformers for nuclear power plants focus on minimizing losses. Through optimized core structures and improved winding designs, they reduce core hysteresis losses and winding resistance losses, enhancing energy conversion efficiency. This lowers power generation costs, reduces unnecessary energy waste and carbon emissions, and aligns with green development concepts.

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m²m² Total staff: 700+ Highest Annual Export(usD): 150000000
Workplace: 108000m²m²
Total staff: 700+
Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding Electrodes
    Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding ElectrodesWhen the grounding electrode of an Ultra-High-Voltage Direct Current (UHVDC) transmission system is located close to a renewable energy power station, the return current flowing through the earth can cause a rise in ground potential around the electrode area. This ground potential rise leads to a shift in the neutral-point potential of nearby power transformers, inducing DC bias (or DC offset) in their
    01/15/2026
  • HECI GCB for Generators – Fast SF6 Circuit Breaker
    1.Definition and Function1.1 Role of the Generator Circuit BreakerThe Generator Circuit Breaker (GCB) is a controllable disconnect point located between the generator and the step-up transformer, serving as an interface between the generator and the power grid. Its primary functions include isolating generator-side faults and enabling operational control during generator synchronization and grid connection. The operating principle of a GCB is not significantly different from that of a standard c
    01/06/2026
  • Distribution Equipment Transformer Testing, Inspection, and Maintenance
    1.Transformer Maintenance and Inspection Open the low-voltage (LV) circuit breaker of the transformer under maintenance, remove the control power fuse, and hang a “Do Not Close” warning sign on the switch handle. Open the high-voltage (HV) circuit breaker of the transformer under maintenance, close the grounding switch, fully discharge the transformer, lock the HV switchgear, and hang a “Do Not Close” warning sign on the switch handle. For dry-type transformer maintenance: first clean the porcel
    12/25/2025
  • How to Test Insulation Resistance of Distribution Transformers
    In practical work, insulation resistance of distribution transformers is generally measured twice: the insulation resistance between thehigh-voltage (HV) windingand thelow-voltage (LV) winding plus the transformer tank, and the insulation resistance between theLV windingand theHV winding plus the transformer tank.If both measurements yield acceptable values, it indicates that the insulation among the HV winding, LV winding, and transformer tank is qualified. If either measurement fails, pairwise
    12/25/2025
  • Design Principles for Pole-Mounted Distribution Transformers
    Design Principles for Pole-Mounted Distribution Transformers(1) Location and Layout PrinciplesPole-mounted transformer platforms should be located near the load center or close to critical loads, following the principle of “small capacity, multiple locations” to facilitate equipment replacement and maintenance. For residential power supply, three-phase transformers may be installed nearby based on current demand and future growth projections.(2) Capacity Selection for Three-Phase Pole-Mounted Tr
    12/25/2025
  • Transformer Noise Control Solutions for Different Installations
    1.Noise Mitigation for Ground-Level Independent Transformer RoomsMitigation Strategy:First, conduct a power-off inspection and maintenance of the transformer, including replacing aged insulating oil, checking and tightening all fasteners, and cleaning dust from the unit.Second, reinforce the transformer foundation or install vibration isolation devices—such as rubber pads or spring isolators—selected based on the severity of vibration.Finally, strengthen sound insulation at weak points of the ro
    12/25/2025

Related Solutions

  • Intelligent Operation Solution for 12kV Vacuum Circuit Breakers: Integrating Real-time Monitoring & Lifetime Optimization
    Ⅰ. Equipment Operation & MaintenanceIntelligent Monitoring System Integration​Multi-parameter Real-time Monitoring: Embedded sensors (temperature, displacement, Hall effect current sensors) track contact temperature rise, mechanical characteristics (opening/closing speed, overtravel), coil current, and partial discharge signals. Data undergoes preprocessing via edge computing prior to cloud upload.​Lifetime Prediction Model: Dynamically evaluates remaining lifespan using electrical wear data
    06/10/2025
  • SF6 Circuit Breaker Solutions for Outdoor Installation (Anti-Pollution & Seismic Resistance)
    I.Core Challenges in Outdoor Installation​In high-voltage transmission and distribution systems, SF6 circuit breakers are exposed to complex outdoor environments for extended periods, facing the following critical issues:​Pollution & Insulation Degradation​Dust, salt fog, and industrial pollutants in outdoor environments easily adhere to equipment surfaces. In coastal or industrial areas, pollution levels may reach ​Class IV, resulting in insufficient creepage distance and triggering ​flasho
    05/12/2025
  • 12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact Design
    12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact DesignⅠ. Executive Summary​Southeast Asia faces rapidly growing electricity demand alongside environmental challenges including high temperatures, humidity, salt spray corrosion, and grid instability. This solution recommends ​Solid Insulated Pole-Mounted Vacuum Circuit Breakers (VCB)​​ featuring ​high reliability, ​compact design, and ​smart monitoring. Tailored for tropical climates and industrial scenarios, it
    06/10/2025
Related Free tools
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.