Model
ZF28-550/4000-63
Basic info
Brand ROCKWILL
Model NO. 550KV 740KV GIS SF6 insulated Switchgear
Rated voltage 550kV
Rated normal current 4000A
Series ZF28
Product Detail

Product Overview:
    ZF28-550 type GIS/ ZH28-550 type HGIS is composed of standard modules through flanged joint, which can meet the demand for substation optimization design through the flexible combination between modules. It saves space and conforms to technical requests.
    This product can be applied to power system, power generation, rail transportation, petrochemical, metallurgy, mining, building materials and other large industrial consumer.

Features and advantages of the product:

  • Fully spring mechanism, high reliability.

  • Excellent breaking ability.

  • The arc extinguish of CB adopts dual break structure, and shunt capacitor to balance the voltage between open contacts, which improves the breaking ability of short-line fault and the breaking current of short circuit is 63kA.

  • E2-M2-C2 circuit breaker; E2 electrical endurance; M2 mechanical endurance.

  • Strong rated current flow capacity.

  • Excellent insulation level, low partial discharge.

  • Excellent corrosion resistance.

  • Advanced Designing tool.

  • Basin-type insolator with aluminium flange; double sealing structure.

  • Strict assembly technology.

  • The domestic first high power spring operation mechanism of circuit breaker has the small volume and is safe and stable, free of maintenance. high reliable and conform to oil free and gas free requirements for operation mechanism.

  •  Interrupter unit adopts shunt capacitor to balance the voltage between open contacts It improves short line  fault breaking capability.

  • Excellent insulation level and low partial discharge. The only company in the industry that can achieve: under the 80% power-frequency withstand voltage (80%×740kV = 592kV), the partial discharge of intervals is lower than 5pC, the partial discharge of the insulator is lower than 3pC. It’s better than the IEC standard that the partial discharge should be lower than 5pC under 1.2 times phase voltage (1.2×550/√3 = 381kV).

  • The insulator quality is stable and reliable. The basin-type insulator pouring process reaches the international advanced level.

Technical Parameters:

image.png

What are the basic requirements for GIS operation?

  • Indoor SF6 equipment room that operators often enter: ventilate at least once per shift, ventilate for 15 minutes, the air exchange volume should be greater than 3-5 times the air volume, and the air outlet should be installed in the lower part of the room; Equipment places that are not frequently visited by operators: ventilate for 15 minutes before entering.

  • During operation, the induced voltage on the shell and frame of GIS should not exceed 36V for the parts that are easily accessible to operation and maintenance personnel.

  • Temperature rise: should not exceed 30K in the part that is easily accessible to operating personnel; The part that is easily accessible to the operator but not touched during operation should not exceed 40K; Individual parts that are not easily accessible to the operator should not exceed 65K.

  • SF6 switchgear inspection at least once a day, unattended substation inspection according to regulations. During the inspection, the visual inspection is mainly carried out, and the equipment is not abnormal, and a record is made.

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
For users, when purchasing a 35kV new energy transformer, choosing between dry-type, mineral oil-filled, or vegetable oil-filled types involves multiple considerations. These include user habits, maintenance-free performance, safety and fire resistance, volume and weight, among others. However, cost differences are undoubtedly one of the most crucial factors.To illustrate the issue intuitively, this paper selects a three-level energy efficiency dual-winding new energy transformer with a rated ca
Ron
07/26/2025
What is the connection group of a transformer?
What is the connection group of a transformer?
Transformer Connection GroupThe connection group of a transformer refers to the phase difference between the primary and secondary voltages or currents. It is determined by the winding directions of the primary and secondary coils, the labeling of their start and end terminals, and the connection mode. Expressed in a clock-like format, there are 12 groups in total, numbered from 0 to 11.The DC method is commonly used to measure the transformer's connection group, mainly to verify whether the con
Vziman
07/26/2025
Working Voltage in Power System
Working Voltage in Power System
Working VoltageThe term "working voltage" refers to the maximum voltage that a device can withstand without sustaining damage or burning out, while ensuring the reliability, safety, and proper operation of both the device and associated circuits.For long-distance power transmission, the use of high voltage is advantageous. In AC systems, maintaining a load power factor as close to unity as possible is also economically necessary. Practically, heavy currents are more challenging to handle than hi
Encyclopedia
07/26/2025
What is Steady State Stability in Power System?
What is Steady State Stability in Power System?
Definition of Steady State StabilitySteady state stability is defined as the capability of an electric power system to sustain its initial operating condition following a small disturbance, or to converge to a state closely approximating the initial condition when the disturbance persists. This concept holds critical significance in power system planning and design, the development of specialized automatic control devices, the commissioning of new system components, and the adjustment of operati
Edwiin
07/26/2025
What is the sequence for powering down the transformer?
What is the sequence for powering down the transformer?
The sequence for shutting down a main transformer is as follows: when de-energizing, the load side should be shut down first, followed by the power supply side. For energizing operations, the reverse order applies: the power supply side is energized first, then the load side. This is because: Energizing from the power supply side to the load side makes it easier to identify the fault range and take prompt judgment and handling measures in case of a fault, preventing the fault from spreading or e
Rockwell
07/26/2025
What are the methods for switching operations of station transformers?
What are the methods for switching operations of station transformers?
Let's take an auxiliary power system with two station transformers as an example. When one station transformer needs to be out of service, there are two operation methods: non-interruptive power supply and instantaneous power interruption. Generally, the method of instantaneous power interruption on the low-voltage side is preferred.The operation method for instantaneous power interruption on the low-voltage side is as follows:Open the 380V power incoming circuit breaker of the corresponding sec
Vziman
07/26/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!