6.3kV 6.6kV 10kV 10.5kV 11kV class S13-M.RL series tridimensional wound core transformer Source manufacturer

  • 6.3kV 6.6kV 10kV 10.5kV 11kV class S13-M.RL series tridimensional wound core transformer Source manufacturer

Key attributes

Brand ROCKWILL
Model NO. 6.3kV 6.6kV 10kV 10.5kV 11kV class S13-M.RL series tridimensional wound core transformer Source manufacturer
Rated voltage 10kV
Rated frequency 50/60Hz
Rated capacity 630kVA
Series S

Product descriptions from the supplier

Description

Product Description

As a pioneer in China's power transformer industry, we have specialized in the R&D and manufacturing of power transformer equipment for decades, and established industry standards with core technologies.

The 10kV class S13-M.RL series represents the pinnacle of efficiency and reliability in distribution transformer technology. Featuring an innovative three-dimensional, continuously wound core design, this transformer achieves a significant reduction in core losses and operating noise compared to traditional laminated core units. Its superior magnetic performance and mechanical strength make it an ideal, eco-friendly choice for utility networks, commercial complexes, and industrial applications where low life-cycle cost and minimal environmental impact are critical. The S13-M.RL series is engineered to deliver exceptional value and dependable performance throughout its extended service life.

Key Features

  • 3D Tridimensional Wound Core Technology:The core consists of three identical single frames in a symmetrical 3D structure, creating a seamless magnetic path that significantly reduces no-load current and hysteresis losses.

  • Exceptional Energy Efficiency:Benefiting from continuously wound silicon steel and an optimized magnetic path, this series achieves ultra-low no-load and load losses, exceeding the Chinese National Standard S13 efficiency class.

  • Significant Noise Reduction:The perfectly symmetrical three-phase magnetic path drastically reduces core vibration. Its compact mechanical structure ensures operation noise is 10-20 dB lower than conventional transformers, ideal for noise-sensitive areas.

  • Enhanced Mechanical & Electrical Stability:The 3D structure provides great mechanical integrity, offering excellent short-circuit resistance, shock withstand, and seismic performance. The uniformly pressed windings further enhance overall reliability.

  • Eco-Friendly and Long Service Life:Higher efficiency translates to reduced energy waste and lower carbon emissions. High-quality materials and robust design ensure a longer service life, making it a reliable green power solution.

Product model

  • S: Three-phase

  • 13: Performance Level

  • M: Hermetically Sealed

  • RL: Tridimensional Wound Core

  • First □: Rated Capacity (kVA)

  • Second □: Rated High Voltage

Performance Parameters - Technical Parameters of S13-M.RL 80~2500/10/0.4 Series Oil-Immersed Distribution Transformer

The voltage classes of some of these Power Transformer include 6kV, 6.3kV, 6.6kV, 6.9kV, 7.2kV, 10kV, 10.5kV, 11kV, 11.5kV, 12kV, 13.2kV, 13.8kV, 14.5kV, 14.4kV, 15kV, 15.5kV, 15.6kV, 17.5kV, 20kV, 21.9kV, 22kV, 24kV, 30kV, 33kV, 33.5kV, 34.5kV, 35kV, 36kV, 38kV, 38.5kV, 40.5kV, 44kV, 45kV, 46kV, 66kV  69kV.72.5kV 88kV 110kV 115kV 123kV 125kV 126kV 132kV 138kV 145kV 150kV 154kV 161kV 170kV  220kV 225kV 230kV 245kV 275kV 330kV 345kV 363kV 380kV 400kV 500kV Power transformers of voltage ,and aboveand customization is available.

Rated Capacity

Voltage Combination and Tap Range

Connection Group

No-load Loss (W)

Load Loss at 120℃ (W)

Short-circuit Impedance (%)

No-load Current (%)

Overall Dimensions

 (Length * Width * Height, mm)

Total Weight (Kg)

Foot Mounting Dimensions (mm)

High Voltage (kV)

Tap Range (%)

Low Voltage (kV)

80

6

6.3

6.6

10

10.5

11

±5

±2×2.5


 

0.4

 

Yyno

Dyn11

130

1310/1250

4.0

0.22

1096 * 722 * 1314

553

380 * 550

100

150

1580/1500

4.0

0.21

1096 * 722 * 1314

607

380 * 550

160

200

2310/2200

4.0

0.19

1080 * 935 * 1411

797

400 * 660

200

240

2730/2600

4.0

0.18

1109 * 960 * 1444

937

400 * 660

250

290

3200/3050

4.0

0.17

1196 * 1036 * 1457

1091

400 * 660

315

340

3830/3650

4.0

0.16

1257 * 1104 * 1467

1239

400 * 820

400

410

4520/4300

4.0

0.16

1306 * 1131 * 1542

1437

400 * 820

500

480

5410/5150

4.0

0.15

1483 * 1284 * 1592

1872

400 * 820

630

570

6200

4.5

0.15

1395 * 1210 * 1649

2085

400 * 820

800

700

7500

4.5

0.14

1503 * 1302 * 1711

2481

400 * 820

1000

830

10300

4.5

0.13

1717 * 1487 * 1726

3000

550 * 1070

1250

970

12000

4.5

0.12

1728 * 1497 * 1836

3404

550 * 1070

1600

1170

14500

4.5

0.11

1880 * 1628 * 1938

4459

550 * 1070

Note: the above parameters are only for typical values, and can be customized according to customer requirements. For transformers with rated capacity of 500kVA and below, the load loss above the diagonal line is applicable to Dyn11 or Yzn11 connection groups. The load loss value below the slash is applicable to the Yyn0 connection group.

Implementation standard: GB1094.1~2-1996, GB1094.3-2003, GB1094.5-2008 power transformers.GB/T6451-2008 three-phase oil immersed power transformer technical parameters and requirements.

Conditions of use

  • No more than 1000m indoor or outdoor

  • The highest ambient air temperature is +40℃, the highest daily average temperature is +30℃.

  • Maximum annual average temperature +20℃ minimum temperature -25℃

  • According to user requirements, transformers can be operated under special conditions.

 

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m²m² Total staff: 700+ Highest Annual Export(usD): 150000000
Workplace: 108000m²m²
Total staff: 700+
Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding Electrodes
    Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding ElectrodesWhen the grounding electrode of an Ultra-High-Voltage Direct Current (UHVDC) transmission system is located close to a renewable energy power station, the return current flowing through the earth can cause a rise in ground potential around the electrode area. This ground potential rise leads to a shift in the neutral-point potential of nearby power transformers, inducing DC bias (or DC offset) in their
    01/15/2026
  • HECI GCB for Generators – Fast SF6 Circuit Breaker
    1.Definition and Function1.1 Role of the Generator Circuit BreakerThe Generator Circuit Breaker (GCB) is a controllable disconnect point located between the generator and the step-up transformer, serving as an interface between the generator and the power grid. Its primary functions include isolating generator-side faults and enabling operational control during generator synchronization and grid connection. The operating principle of a GCB is not significantly different from that of a standard c
    01/06/2026
  • Distribution Equipment Transformer Testing, Inspection, and Maintenance
    1.Transformer Maintenance and Inspection Open the low-voltage (LV) circuit breaker of the transformer under maintenance, remove the control power fuse, and hang a “Do Not Close” warning sign on the switch handle. Open the high-voltage (HV) circuit breaker of the transformer under maintenance, close the grounding switch, fully discharge the transformer, lock the HV switchgear, and hang a “Do Not Close” warning sign on the switch handle. For dry-type transformer maintenance: first clean the porcel
    12/25/2025
  • How to Test Insulation Resistance of Distribution Transformers
    In practical work, insulation resistance of distribution transformers is generally measured twice: the insulation resistance between thehigh-voltage (HV) windingand thelow-voltage (LV) winding plus the transformer tank, and the insulation resistance between theLV windingand theHV winding plus the transformer tank.If both measurements yield acceptable values, it indicates that the insulation among the HV winding, LV winding, and transformer tank is qualified. If either measurement fails, pairwise
    12/25/2025
  • Design Principles for Pole-Mounted Distribution Transformers
    Design Principles for Pole-Mounted Distribution Transformers(1) Location and Layout PrinciplesPole-mounted transformer platforms should be located near the load center or close to critical loads, following the principle of “small capacity, multiple locations” to facilitate equipment replacement and maintenance. For residential power supply, three-phase transformers may be installed nearby based on current demand and future growth projections.(2) Capacity Selection for Three-Phase Pole-Mounted Tr
    12/25/2025
  • Transformer Noise Control Solutions for Different Installations
    1.Noise Mitigation for Ground-Level Independent Transformer RoomsMitigation Strategy:First, conduct a power-off inspection and maintenance of the transformer, including replacing aged insulating oil, checking and tightening all fasteners, and cleaning dust from the unit.Second, reinforce the transformer foundation or install vibration isolation devices—such as rubber pads or spring isolators—selected based on the severity of vibration.Finally, strengthen sound insulation at weak points of the ro
    12/25/2025

Related Solutions

  • Intelligent Operation Solution for 12kV Vacuum Circuit Breakers: Integrating Real-time Monitoring & Lifetime Optimization
    Ⅰ. Equipment Operation & MaintenanceIntelligent Monitoring System Integration​Multi-parameter Real-time Monitoring: Embedded sensors (temperature, displacement, Hall effect current sensors) track contact temperature rise, mechanical characteristics (opening/closing speed, overtravel), coil current, and partial discharge signals. Data undergoes preprocessing via edge computing prior to cloud upload.​Lifetime Prediction Model: Dynamically evaluates remaining lifespan using electrical wear data
    06/10/2025
  • SF6 Circuit Breaker Solutions for Outdoor Installation (Anti-Pollution & Seismic Resistance)
    I.Core Challenges in Outdoor Installation​In high-voltage transmission and distribution systems, SF6 circuit breakers are exposed to complex outdoor environments for extended periods, facing the following critical issues:​Pollution & Insulation Degradation​Dust, salt fog, and industrial pollutants in outdoor environments easily adhere to equipment surfaces. In coastal or industrial areas, pollution levels may reach ​Class IV, resulting in insufficient creepage distance and triggering ​flasho
    05/12/2025
  • 12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact Design
    12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact DesignⅠ. Executive Summary​Southeast Asia faces rapidly growing electricity demand alongside environmental challenges including high temperatures, humidity, salt spray corrosion, and grid instability. This solution recommends ​Solid Insulated Pole-Mounted Vacuum Circuit Breakers (VCB)​​ featuring ​high reliability, ​compact design, and ​smart monitoring. Tailored for tropical climates and industrial scenarios, it
    06/10/2025
Related Free tools
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.