• Amorphous alloy dry-type transformer 200kVA 250kVA 315kVA 400kVA
Amorphous alloy dry-type transformer 200kVA 250kVA 315kVA 400kVA
discuss personally
Model
SC (B) H-15KV-400KVA
SC (B) H-15KV-315KVA
SC (B) H-15KV-250KVA
SC (B) H-15KV-200KVA
Basic info
Brand Vziman
Model NO. Amorphous alloy dry-type transformer 200KVA 250KVA 315KVA 400KVA
Rated capacity 200kVA
Voltage grade 15KV
Series SC (B) H15
Product Detail

Description

The amorphous alloy dry-type transformer represents a mature energy-saving solution in dry-type transformer technology. This product stands out for its low no-load loss, flame-retardant self-extinguishing properties, moisture resistance, crack resistance, and maintenance-free operation. Ideal for replacing conventional dry transformers, it is widely applicable in high-rise buildings, commercial centers, subways, airports, stations, industrial and mining enterprises, and power plants. Specifically designed for installation in fire-sensitive environments, it is particularly suitable for flammable or explosive zones, meeting strict fire protection requirements with optimal safety and reliability.

Key Advantages

  • Energy Efficiency: Significantly reduces no-load loss, contributing to lower operational costs and environmental sustainability.

  • Safety Features: Self-extinguishing and flame-retardant design minimizes fire risks, while moisture and crack resistance ensure stable performance in diverse conditions.

  • Versatile Application: Compatible with all scenarios using traditional dry transformers, including high-density urban infrastructure and industrial settings with strict safety norms.

  • Low Maintenance: Engineered for hassle-free operation, eliminating the need for regular upkeep and enhancing system durability.

Parameter:

企业微信截图_172309516528.png



What is an amorphous alloy dry-type transformer?

Amorphous Alloy Dry - type Transformer is a kind of dry - type transformer that uses amorphous alloy material as the iron core. The amorphous alloy material has unique physical and chemical properties, which enable it to exhibit excellent performance in transformer applications. This kind of transformer is widely used in situations where high energy - efficiency and environmental - protection requirements are emphasized.

Basic Definitions:

  • Amorphous Alloy: An amorphous alloy is a metallic material with an amorphous structure, usually composed of elements such as iron, boron, and silicon. The atomic arrangement of this material does not have a fixed lattice structure, thus possessing unique physical and chemical properties.

  • Dry-type Transformer: A dry-type transformer is a type of transformer that does not use a liquid cooling medium (such as transformer oil). It usually adopts natural air cooling or forced air cooling.

Structural Characteristics:

  • Iron Core: The iron core made of amorphous alloy material has extremely low hysteresis loss and eddy current loss.

  • Coil: Usually wound with copper or aluminum wires, it has good electrical properties.

  • Insulation Materials: High-quality insulation materials such as epoxy resin are used to ensure the safety of the transformer operating under high voltage.

  • Cooling Methods: Generally, natural air cooling (AN) or forced air cooling (AF) is adopted. The appropriate cooling method is selected according to specific application requirements.


Know your supplier
Vziman
Zhejiang Vziman Electric Group Co., Ltd. is a high-tech enterprise specializing in R&D, manufacturing, and service of power electrical equipment. Committed to innovation, quality, and customer satisfaction, it supplies smart solutions for global power sectors, covering grid construction, new energy, and industrial distribution. Core Business • Switchgear (GIS, circuit breakers, Recloser, Load break switch) • Distribution equipment (transformers, RMU, smart terminals) • Power automation systems • Engineering services (installation, maintenance, consulting) Technical Strength • Provincial R&D center, multiple patents • Modern production, ISO/GB/IEC/CE/UL certified • High capacity, large-scale delivery support Market & Vision Serves State Grid, Southern Grid, and global projects (Asia, Africa, Europe, etc.). Aims to lead in smart grids and new energy, promoting sustainable energy development.
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150000000
Professional Experience
3 years
Workplace
10000m²
占位
占位
Related Knowledges
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
For users, when purchasing a 35kV new energy transformer, choosing between dry-type, mineral oil-filled, or vegetable oil-filled types involves multiple considerations. These include user habits, maintenance-free performance, safety and fire resistance, volume and weight, among others. However, cost differences are undoubtedly one of the most crucial factors.To illustrate the issue intuitively, this paper selects a three-level energy efficiency dual-winding new energy transformer with a rated ca
Ron
07/26/2025
What is the connection group of a transformer?
What is the connection group of a transformer?
Transformer Connection GroupThe connection group of a transformer refers to the phase difference between the primary and secondary voltages or currents. It is determined by the winding directions of the primary and secondary coils, the labeling of their start and end terminals, and the connection mode. Expressed in a clock-like format, there are 12 groups in total, numbered from 0 to 11.The DC method is commonly used to measure the transformer's connection group, mainly to verify whether the con
Vziman
07/26/2025
Working Voltage in Power System
Working Voltage in Power System
Working VoltageThe term "working voltage" refers to the maximum voltage that a device can withstand without sustaining damage or burning out, while ensuring the reliability, safety, and proper operation of both the device and associated circuits.For long-distance power transmission, the use of high voltage is advantageous. In AC systems, maintaining a load power factor as close to unity as possible is also economically necessary. Practically, heavy currents are more challenging to handle than hi
Encyclopedia
07/26/2025
What is Steady State Stability in Power System?
What is Steady State Stability in Power System?
Definition of Steady State StabilitySteady state stability is defined as the capability of an electric power system to sustain its initial operating condition following a small disturbance, or to converge to a state closely approximating the initial condition when the disturbance persists. This concept holds critical significance in power system planning and design, the development of specialized automatic control devices, the commissioning of new system components, and the adjustment of operati
Edwiin
07/26/2025
What is the sequence for powering down the transformer?
What is the sequence for powering down the transformer?
The sequence for shutting down a main transformer is as follows: when de-energizing, the load side should be shut down first, followed by the power supply side. For energizing operations, the reverse order applies: the power supply side is energized first, then the load side. This is because: Energizing from the power supply side to the load side makes it easier to identify the fault range and take prompt judgment and handling measures in case of a fault, preventing the fault from spreading or e
Rockwell
07/26/2025
What are the methods for switching operations of station transformers?
What are the methods for switching operations of station transformers?
Let's take an auxiliary power system with two station transformers as an example. When one station transformer needs to be out of service, there are two operation methods: non-interruptive power supply and instantaneous power interruption. Generally, the method of instantaneous power interruption on the low-voltage side is preferred.The operation method for instantaneous power interruption on the low-voltage side is as follows:Open the 380V power incoming circuit breaker of the corresponding sec
Vziman
07/26/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!