• DS4D 420kV 550kV High voltage disconnect switch
DS4D 420kV 550kV High voltage disconnect switch
discuss personally
Model
DS4D-550/4000-63
DS4D-550/2500-50
DS4D-420/4000-63
DS4D-420/2500-50
Basic info
Brand ROCKWILL
Model NO. DS4D 420kV 550kV High voltage disconnect switch
Rated voltage 550kV
Rated normal current 2500A
Rated frequency 50/60Hz
Rated peak value withstand current 125kA
Rated short-time withstand current 50kA
Series DS4D
Product Detail

Product introduction

This switch Switch Disconnector is a Kind of outdoor HV electricity transmission equipment’s at three-phase AC frequency of 50Hz/60Hz.lt is used for breaking or connecting HV lines under no loads so that there lines can be changed and connected and the way the electricity runs is changed. In addition, it can be used to exercise safe electrical insulation for such HV electric apparatuses as bus and breaker. The switch can open and close inductance/capacitance current and is able to open and dose the bus to switch current

Main characteristic

  • The product chassis adopts an integrated design to ensure that the upper conductive does not generate a large displacement under the tensile force of the terminal, and improves the reliability of the product closing.
  • The bearing housing is designed according to the maintenance-free requirements. The bearing seat is sealed by a fully sealed rain cover, wool felt seal and sealing ring. Water vapor, dust and harmful gases cannot enter, and the grease in the bearing does not drain during the life cycle., does not cure, especially suitable for Windy sand areas
  • The finger is made of pure copper and has a silver plating process. It has strong flow capacity and tong mechanical life. The stamping process ensures the reliability of contact and finger contact
  • The contact finger pressure is proportional to the primary insertion depth of the contact, the sensitivity is low, the contact insertion area is long, the on-site debugging is difficult, and the product is highly reliable against adverse interference such as harsh environment (winding of the flexible Wire).
  • The earth switch uses a torsion spring to balance its own weight and torque, making it light and flexible. The base adopts a suspended structure. which is convenient for on-site adjustment. The grounding switch static contact adopts self-powered plum-shaped finger. which has simple structure, many contact points and high technical performance index.
  • Provide one-key sequential control "double confirmation" function expansion.

Main technical parameters

Order notice 

Please indicate the service condition;

Please indicate the product type、 Rated voltage、 Rated current、 Rated short time withstand current、creepage distance and so on;

Please indicate the motor voltage、 control circuit’s voltage、pollution region and auxiliary switch connection number;

Please indicate whether the steel bracket is provided;

Please indicate whether the interphase cable is provided, and specify the cable length and type;

Please indicate other special requirements

 

 

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
For users, when purchasing a 35kV new energy transformer, choosing between dry-type, mineral oil-filled, or vegetable oil-filled types involves multiple considerations. These include user habits, maintenance-free performance, safety and fire resistance, volume and weight, among others. However, cost differences are undoubtedly one of the most crucial factors.To illustrate the issue intuitively, this paper selects a three-level energy efficiency dual-winding new energy transformer with a rated ca
Ron
07/26/2025
What is the connection group of a transformer?
What is the connection group of a transformer?
Transformer Connection GroupThe connection group of a transformer refers to the phase difference between the primary and secondary voltages or currents. It is determined by the winding directions of the primary and secondary coils, the labeling of their start and end terminals, and the connection mode. Expressed in a clock-like format, there are 12 groups in total, numbered from 0 to 11.The DC method is commonly used to measure the transformer's connection group, mainly to verify whether the con
Vziman
07/26/2025
Working Voltage in Power System
Working Voltage in Power System
Working VoltageThe term "working voltage" refers to the maximum voltage that a device can withstand without sustaining damage or burning out, while ensuring the reliability, safety, and proper operation of both the device and associated circuits.For long-distance power transmission, the use of high voltage is advantageous. In AC systems, maintaining a load power factor as close to unity as possible is also economically necessary. Practically, heavy currents are more challenging to handle than hi
Encyclopedia
07/26/2025
What is Steady State Stability in Power System?
What is Steady State Stability in Power System?
Definition of Steady State StabilitySteady state stability is defined as the capability of an electric power system to sustain its initial operating condition following a small disturbance, or to converge to a state closely approximating the initial condition when the disturbance persists. This concept holds critical significance in power system planning and design, the development of specialized automatic control devices, the commissioning of new system components, and the adjustment of operati
Edwiin
07/26/2025
What is the sequence for powering down the transformer?
What is the sequence for powering down the transformer?
The sequence for shutting down a main transformer is as follows: when de-energizing, the load side should be shut down first, followed by the power supply side. For energizing operations, the reverse order applies: the power supply side is energized first, then the load side. This is because: Energizing from the power supply side to the load side makes it easier to identify the fault range and take prompt judgment and handling measures in case of a fault, preventing the fault from spreading or e
Rockwell
07/26/2025
What are the methods for switching operations of station transformers?
What are the methods for switching operations of station transformers?
Let's take an auxiliary power system with two station transformers as an example. When one station transformer needs to be out of service, there are two operation methods: non-interruptive power supply and instantaneous power interruption. Generally, the method of instantaneous power interruption on the low-voltage side is preferred.The operation method for instantaneous power interruption on the low-voltage side is as follows:Open the 380V power incoming circuit breaker of the corresponding sec
Vziman
07/26/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!