• DS5A 40.5kV 72.5kV 126kV High voltage disconnect switch
DS5A 40.5kV 72.5kV 126kV High voltage disconnect switch
discuss personally
Model
DS5A-126/3150-50
DS5A-126/2500-50
DS5A-126/2000-50
DS5A-126/1250-50
DS5A-72.5/4000-40
DS5A-72.5/3150-40
DS5A-72.5/2500-40
DS5A-72.5/2000-40
DS5A-72.5/1250-40
DS5A-40.5/4000-20
DS5A-40.5/2500-20
DS5A-40.5/2000-20
DS5A-40.5/1250-20
DS5A-40.5/630-20
Basic info
Brand ROCKWILL
Model NO. DS5A 40.5kV 72.5kV 126kV High voltage disconnect switch
Rated voltage 72.5kV
Rated normal current 2500A
Rated frequency 50/60Hz
Rated peak value withstand current 100kA
Rated short-time withstand current 40kA
Series DS5A
Product Detail

Product introduction:

DS5A Switch Disconnector Is a kind of outdoor HV electricity transmission equipment’s al three-phase AC frequency of 50Hz/60Hz. It Is used for breaking or connecting HV lines under no loads so that the power lines can be changed and connected and the way the electricity runs is changed. In addition it can be used to exercise safe eleclrica.1 insulation for such HV electric apparatuses as bus and break.

This product has two posts with horizontal open breaks. It Is open able In the middle and accessible to the grounding switch on one side or two sides. 90°drive's isolating switch and grounding switches adopt cs11 manual operating mechanism to execute the tri-pole linkage;180°drive's isolating switch adopts CS11 manual operating mechanism or CS14g manual to execute the tri-pole linkage; the grounding Switch adopts CS11 manual actuator to realize the tri-pole linkage.

DS5A Switch Disconnector comprises three single poles and actuator. Each single pole is made of a base, post insulator and conductive part. Two rotating post insulators are installed at a base with two insulators forming an angle of 50° and arranged in V shape. The contact finger arms and contact head arms of the conductive knife switch are separately fixed onto the end of the Insulating post.

The actuator drives one side of the insulating post to revolve, and drives the other side of the insulating post to rotate reversely by 90° through the angular wheel or link lever, so that the knife switch will be in circumgyration to realize the opening and closing of the Switch Disconnector. A horizontal insulating open break will appear at the closing moment.

Main characteristic:

  • The conductive arm made of rectangular Al-alloy pipes is characterized by high strength, light, weigh, large radiation area and strong resistance against corruption.
  • DS5A adopts particular copper alloy to develop the self-contained contact. The contact point is tightened by the elastic force of the contact itself. The contact spring is eliminated to avoid possible drop of the contact in gripping force due to the spring's corrosion and shunting, possible heating and annealing, possible increment in contact resistance, and possible vicious cycle of the growing heat or the contact The contact is made of curved copper plate, forming a large connection area with the conductive arm. In the opening and dosing processes, there is a short trip of friction between the contact and the finger and the required operating force is small. The conductive part has been acknowledged by the Chinese competent authority as a new and practical patent.(Patent No.: 2103 2 20022.6)
  • The rotating parts of the Switch Disconnector are designed to be free of maintenance. The rotating base is designed into a closure structure which denies the access of moisture, dust and harmful gases so that the low-temperature lubricating cream within the bearing will not run off or harden. Within the bearing base are thrust ball bearing and radial ball bearing, both of which will share the gravity and horizontal component of the Switch Disconnector so that the operating torque will not increase after the long-term operation of the disconnect switch
  • The mechanical interlock between the primary switch and earthing switch is directly installed onto the principal axis of the primary switch and the revolution axis of the earthing switch. The interlock Is direct and reliable, eliminating the structurally complex gearbox. It also facilitates easy adjustment In the field erection and avoids the corrosion of the gear box.
  • Provide one-key sequential control "double confim1ation" function expansion

Main technical parameters:

GW5A-parameters.png

Order notice :

Product model, current, rated short-time withstand current and creepage distance must be specified at the goods-ordering time;

The Switch Disconnector offers several options of grounding (no, left, right, both left and right). Unless otherwise specified, the goods suppled will be considered as providing the option of right grounding;

The operating mechanism, voltage and the number of contacts for auxiliary switch;

Methods of installation: horizontal installation, installation by the iodination of 25",side installation. Unless otherwise specified, the horizontal installation will be taken as default;

Specify the type of power and voltage degree for the electromagnetic lock of the actuator.

 

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
For users, when purchasing a 35kV new energy transformer, choosing between dry-type, mineral oil-filled, or vegetable oil-filled types involves multiple considerations. These include user habits, maintenance-free performance, safety and fire resistance, volume and weight, among others. However, cost differences are undoubtedly one of the most crucial factors.To illustrate the issue intuitively, this paper selects a three-level energy efficiency dual-winding new energy transformer with a rated ca
Ron
07/26/2025
What is the connection group of a transformer?
What is the connection group of a transformer?
Transformer Connection GroupThe connection group of a transformer refers to the phase difference between the primary and secondary voltages or currents. It is determined by the winding directions of the primary and secondary coils, the labeling of their start and end terminals, and the connection mode. Expressed in a clock-like format, there are 12 groups in total, numbered from 0 to 11.The DC method is commonly used to measure the transformer's connection group, mainly to verify whether the con
Vziman
07/26/2025
Working Voltage in Power System
Working Voltage in Power System
Working VoltageThe term "working voltage" refers to the maximum voltage that a device can withstand without sustaining damage or burning out, while ensuring the reliability, safety, and proper operation of both the device and associated circuits.For long-distance power transmission, the use of high voltage is advantageous. In AC systems, maintaining a load power factor as close to unity as possible is also economically necessary. Practically, heavy currents are more challenging to handle than hi
Encyclopedia
07/26/2025
What is Steady State Stability in Power System?
What is Steady State Stability in Power System?
Definition of Steady State StabilitySteady state stability is defined as the capability of an electric power system to sustain its initial operating condition following a small disturbance, or to converge to a state closely approximating the initial condition when the disturbance persists. This concept holds critical significance in power system planning and design, the development of specialized automatic control devices, the commissioning of new system components, and the adjustment of operati
Edwiin
07/26/2025
What is the sequence for powering down the transformer?
What is the sequence for powering down the transformer?
The sequence for shutting down a main transformer is as follows: when de-energizing, the load side should be shut down first, followed by the power supply side. For energizing operations, the reverse order applies: the power supply side is energized first, then the load side. This is because: Energizing from the power supply side to the load side makes it easier to identify the fault range and take prompt judgment and handling measures in case of a fault, preventing the fault from spreading or e
Rockwell
07/26/2025
What are the methods for switching operations of station transformers?
What are the methods for switching operations of station transformers?
Let's take an auxiliary power system with two station transformers as an example. When one station transformer needs to be out of service, there are two operation methods: non-interruptive power supply and instantaneous power interruption. Generally, the method of instantaneous power interruption on the low-voltage side is preferred.The operation method for instantaneous power interruption on the low-voltage side is as follows:Open the 380V power incoming circuit breaker of the corresponding sec
Vziman
07/26/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!