• DS6B 126kV 145kV 252kV 420kV 550kV High voltage disconnect switch
DS6B 126kV 145kV 252kV 420kV 550kV High voltage disconnect switch
discuss personally
Model
DS6B-550D/4000-63
DS6B-420D/4000-63
DS5A-252/5000-63
DS6B-252D/4000-63
DS6B-252D/3150-50
DS6B-252D/2000-40
DS6B-145D/3150-50
DS6B-145D/2000-40
DS6B-126D/3150-50
DS6B-126D/2000-50
Basic info
Brand ROCKWILL
Model NO. DS6B 126kV 145kV 252kV 420kV 550kV High voltage disconnect switch
Rated voltage 252kV
Rated normal current 4000A
Rated frequency 50/60Hz
Rated peak value withstand current 160kA
Rated short-time withstand current 63kA
Series DS6B
Product Detail

Product introduction:

DSDS6B Switch Disconnector is a kind of outdoor HV electricity transmission equipment’s at three-phase AC frequency of 50Hz/60Hz. It is used for breaking or connecting HV lines under no loads so that these lines can be changed and connected and the way the electricity runs is changed, In addition, it can be used to exercise safe electrical insulation for such HV electric

apparatuses as bus and breaker. The switch can open and close inductance/capacitance current and is able to open and close the bus to switch current.

This product is of the single-post bi-arm vertical telescope type (scissor-type) and suitable for the bus's Switch Disconnector. It can be laid out directly under the bus, thus occupying a small area. It’s effect of saving energy can be prominent at the substation where double bus lines are accompanied by the bypass bus.

The Switch Disconnector is accompanied by a JW10 earthing switch which will be used for the bus grounding at the lower layer, The grounding of the bus line at the upper layer requires the use of an independent earthing switch. 363kV and 550Kv Switch Disconnector and earthing switch are equipped with the SRCJ8 motor actuator for the single pole operation. Meanwhile, the tri-pole linkage can be achieved. The 126kV and 252kV Switch Disconnector adopt SRCJ3 motor-based actuator to realize the tri-pole linkage. The earthing switch adopts SRCS manual actuator to actualize tri-pole linkage.

This Switch Disconnector has passed the verification by the review procedure organized by China Machinery industry federation that the product structure and performance satisfy the requirements on perfection, and product's performance indices have reached the internally level of the same kinds of products

DS6B Switch Disconnector comprises three single poles and actuator. Each single pole is made of a base, post insulator, operating insulator and conducive part., The conductive pat includes the gear box and foldable conductive am fixed on the top of the post insulator, and the fixed contact hanging on the overload bus.

The actuator dives the operating insulator, and through the four link lever-driven scissor-type conductive arm, lift and lower the insulator to tighten or separate the moving contact and fixed contact on the directly overhead bus line, to open or close the Switch Disconnector. After the closing, a vertical insulating break will be formed.

Main characteristic:

  • Superior conductance system; With open structure, conductor is laid out in the middle of the transmission base while the main rod and reverse connecting rod are installed outside. Balancing spring is sealed with aluminum cover and transmission parts needing debugging are exposed for easy installation and debugging. dust prevention. Add a dustcover to bearing and adopt seal structure externally.
  • Contact forceps can cover a large area of rated contact, This product is in the double arm telescopic (scissor-type) structure. The forceps of the moving contact cover a large area of rated contact, particularly applicable to soft bus line, and also to hard bus line.
  • Open gear box, which has a good visibility, is convenient for installation, debugging and maintenance. The main crank arm is combined with operating flange to reduce he transmission link and the height of transmission base, which can improve the transmission efficiency and reliability. The rotation shat is designed as double bearing structure so that the transmission is flexible and reliable.
  • Structural design: the separation of machines from power. The design concept is the separation of machines from power, that is, the conductive elements, springs and mechanic driving elements are mutually isolated to prevent current from passing through springs and mechanical driving elements. in this way, the stability of the driving elements can be enhanced.
  • Provide one key sequential control "double confirmation" function expansion.

Main technical parameters:

Order notice 

Product model, rated voltage, rated current, rated short-lime withstand current and creepage distance must be specified at the goods-ordering time;

It must be decided whether a earthing switch should be attached to the Switch Disconnector;it must be decided whether the upper bus line of the Switch Disconnector is soft or hard.

Additionally, the external diameter of the tubular busbar shall be specified;

It must be decided whether the Switch Disconnector is arranged in cross-over or parallel form;

The actuator's model and name, motor's voltage, control voltage and the number of contacts for auxiliary switch

 

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
For users, when purchasing a 35kV new energy transformer, choosing between dry-type, mineral oil-filled, or vegetable oil-filled types involves multiple considerations. These include user habits, maintenance-free performance, safety and fire resistance, volume and weight, among others. However, cost differences are undoubtedly one of the most crucial factors.To illustrate the issue intuitively, this paper selects a three-level energy efficiency dual-winding new energy transformer with a rated ca
Ron
07/26/2025
What is the connection group of a transformer?
What is the connection group of a transformer?
Transformer Connection GroupThe connection group of a transformer refers to the phase difference between the primary and secondary voltages or currents. It is determined by the winding directions of the primary and secondary coils, the labeling of their start and end terminals, and the connection mode. Expressed in a clock-like format, there are 12 groups in total, numbered from 0 to 11.The DC method is commonly used to measure the transformer's connection group, mainly to verify whether the con
Vziman
07/26/2025
Working Voltage in Power System
Working Voltage in Power System
Working VoltageThe term "working voltage" refers to the maximum voltage that a device can withstand without sustaining damage or burning out, while ensuring the reliability, safety, and proper operation of both the device and associated circuits.For long-distance power transmission, the use of high voltage is advantageous. In AC systems, maintaining a load power factor as close to unity as possible is also economically necessary. Practically, heavy currents are more challenging to handle than hi
Encyclopedia
07/26/2025
What is Steady State Stability in Power System?
What is Steady State Stability in Power System?
Definition of Steady State StabilitySteady state stability is defined as the capability of an electric power system to sustain its initial operating condition following a small disturbance, or to converge to a state closely approximating the initial condition when the disturbance persists. This concept holds critical significance in power system planning and design, the development of specialized automatic control devices, the commissioning of new system components, and the adjustment of operati
Edwiin
07/26/2025
What is the sequence for powering down the transformer?
What is the sequence for powering down the transformer?
The sequence for shutting down a main transformer is as follows: when de-energizing, the load side should be shut down first, followed by the power supply side. For energizing operations, the reverse order applies: the power supply side is energized first, then the load side. This is because: Energizing from the power supply side to the load side makes it easier to identify the fault range and take prompt judgment and handling measures in case of a fault, preventing the fault from spreading or e
Rockwell
07/26/2025
What are the methods for switching operations of station transformers?
What are the methods for switching operations of station transformers?
Let's take an auxiliary power system with two station transformers as an example. When one station transformer needs to be out of service, there are two operation methods: non-interruptive power supply and instantaneous power interruption. Generally, the method of instantaneous power interruption on the low-voltage side is preferred.The operation method for instantaneous power interruption on the low-voltage side is as follows:Open the 380V power incoming circuit breaker of the corresponding sec
Vziman
07/26/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!