For use in automatic conductor winding machines for transformers

  • For use in automatic conductor winding machines for transformers

Key attributes

Brand Switchgear parts
Model NO. For use in automatic conductor winding machines for transformers
Winding speed 0-375 rpm
Load 1000kg
Flat wire size 14mmx4mm
Conductor diameter 1-4mm
Outer diameter of winding 600mm
Clearance between chuck and tailstock 1200mm
Series WZR

Product descriptions from the supplier

Description

Application

The automatic wire guiding winding machine isan advanced specialized machine for small andmiddle size distribution transformer coils. The mass production process of transformer coils includes dry-type transformers, oil immersed transformers, special transformers, and so on

Features

Touch screen for easy operation
High accuracy wire guiding
The movable tailstock, easy for unloading & loading coils
Available for round and flat wire
Full width insulation paper is easy for loading and clamping
Technical specification

No.

Items

WZR-1/1200

WZR-2/1600

1

Max load

1000 kg

2000 kg

2

Outer diameter of winding

600 mm

600 mm

3

Wire ranking direction

Double direction

Double direction

4

Clearance between chuck and tailstock

1200 mm

1600 mm

5

Winding speed

0-375 rpm

0-375 rpm

6

Round wire diameter

1-4mm

1-4mm

7

Flat wire size

Max.4×14mm

Max.4×14mm

Documentation Resource Library
Public.
For use in automatic conductor winding machines for transformers
Catalogue
English
FAQ
Q: What is the practical significance of the "bidirectional wiring" and "compatibility with round and flat wires" functions of this device for the processing of coils in small and medium-sized distribution transformers?
A:

The practical significance includes: ① The bidirectional wiring function can adapt to coil designs with different winding directions, without the need to adjust equipment layout, improving processing flexibility; ② Compatible with round wire (1-4mm) and flat wire (up to 4 × 14mm), covering the mainstream wire specifications of small and medium-sized distribution transformer coils, enterprises do not need to separately configure equipment for different wires, reducing equipment investment costs and reducing changeover adjustment time.

Q: What are the core differences in parameters between the two models of this device, and how should enterprises select based on production needs?
A:

The core differences are concentrated in the maximum load and the distance between the chuck and the tailstock: WZR-1/1200 has a load of 1000kg and a distance of 1200mm; WZR-2/1600 has a load of 2000kg and a distance of 1600mm. Selection suggestions: ① Production of small distribution transformer coils (load ≤ 1000kg, coil length adapted to a distance of 1200mm), choose WZR-1/1200; ② Produce medium-sized distribution transformer coils (load ≤ 2000kg, coil length adapted to 1600mm spacing), choose WZR-2/1600.

Q: What is the core application scenario of this automatic wire guiding winding machine, and what are the operational advantages compared to ordinary winding machines?
A:

The core application scenario is the processing of coils for small and medium-sized distribution transformers. The operational advantages include: ① easier coil loading and unloading process, reducing the labor intensity of manual handling and fixation; ② Easy clamping of insulation paper reduces auxiliary operation time; ③ The overall operation is more convenient, without the need for complex parameter debugging, and the threshold for getting started is lower.

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: Highest Annual Export(usD): 300000000
Workplace: 1000m²
Total staff:
Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: Low Voltage Electrical Apparatus/Instrument meters/Production equipment/Tester/High Voltage Electrical Apparatus/Electrical fittings/Equipment Parts
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
  • What’s the Difference Between Rectifier Transformers and Power Transformers?
    What is a Rectifier Transformer?"Power conversion" is a general term encompassing rectification, inversion, and frequency conversion, with rectification being the most widely used among them. Rectifier equipment converts input AC power into DC output through rectification and filtering. A rectifier transformer serves as the power supply transformer for such rectifier equipment. In industrial applications, most DC power supplies are obtained by combining a rectifier transformer with rectifier equ
    01/29/2026
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application