• 110kV Porcelain housed Surge Arrester
110kV Porcelain housed Surge Arrester
discuss personally
Model
Y10WZ-300/727
HY10WZ-200/520
HY10WZ-100/260
HY5WS-10/30
Basic info
Brand Wone
Model NO. 110kV Porcelain housed Surge Arrester
Rated voltage 300kV
Continuous operating voltage 228kV
Lightning impulse residual voltage 727kV
Series Surge Arrester
Product Detail

Product introduction:

  • Surge arrester is also called overvoltage protector. It is connected in parallel with the protected electrical equipment. It can limit various overvoltage on electrical equipment, such as lightning overvoltage, operating overvoltage, etc., so as to protect the high voltage electrical from the damage of overvoltage.

  • Metaloxide varistor is used as the core component of surge arrester. The conductive mechanism of MOV is based on the non-linear volt-ampere characteristics of Schottky barrier model. The arrester is based on the principle of the non-linear volt-ampere characteristic of metal oxide varistor, which makes the arrester hold high resistance under the normal operating voltage of power system, which is equivalent to an insulator, and will not interfere with the normal operation of power system. When the overvoltage of power system endangers the safe operation of the system, the varistor triggers instantaneously and presents a low resistance. Forming a channel to release overvoltage energy, and clamp system voltage within the allowable range of the system to ensure the safe operation of the power system.

  • The arrester is porcelain-housed surge arrester. It has the advantages of high current impulse withstand capacity, large protection capacity and strong pollution resistance.

Parameter:

企业微信截图_17341409149808.png

 What are the structural characteristics of the porcelain shell arrester?

Porcelain Housing

The porcelain housing is a critical external structural component, offering excellent insulation properties and mechanical strength. The porcelain material can withstand electric field intensities of up to 110kV, preventing flashovers between internal components and the external environment. Additionally, the porcelain housing can endure certain mechanical stresses, such as wind and vibrations, protecting the sensitive internal components. Typically cylindrical in shape with a smooth surface, the porcelain housing helps reduce the adhesion of dust and contaminants. During manufacturing, it undergoes rigorous quality inspections to ensure there are no cracks or defects that could compromise its insulating properties.

Internal Components

The core internal component is the zinc oxide varistor disc. Under normal operating voltage, the zinc oxide varistor disc exhibits a high-resistance state, allowing only minimal current to pass through. When overvoltage occurs, its resistance drops sharply, forming a low-resistance path that allows the overvoltage-induced current to pass smoothly. These discs are made primarily from zinc oxide using specialized manufacturing processes, resulting in nonlinear volt-ampere characteristics that effectively limit the amplitude of overvoltages. Additionally, the internal structure may include connecting elements to link the varistor discs appropriately and auxiliary components like grading rings to ensure uniform voltage distribution across the discs during high-voltage conditions.

Sealing and Connection Structure

The porcelain-housed surge arrester features a robust sealing structure to prevent moisture, dust, and harmful gases from entering and affecting the performance of internal components. At both ends, there are connection structures for integrating the arrester into 110kV power lines. These connection parts are typically made of metal, capable of withstanding high voltages and large currents while providing excellent conductivity. This ensures that during an overvoltage event, current can flow smoothly into and out of the arrester.

Know your supplier
Wone
Main Categories
High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$50,000,000
Professional Experience
1 years
Workplace
65666m²m²
占位
占位
Related Products
Related Knowledges
An Intelligent Device for Insulation Restoration of Low-Voltage Overhead Cables
An Intelligent Device for Insulation Restoration of Low-Voltage Overhead Cables
1. Current Situation and ProblemsLow - voltage overhead cables often suffer insulation damage. Urbanization and infrastructure construction expose them to complex environments (construction, severe weather like strong winds/rains causing scratches or impacts, animal damage), easily breaking insulation layers. Long - term operation also degrades insulation due to aging, corrosion, and prolonged sunlight—e.g., cables in old communities age and crack, raising failure risks.Existing restoratio
Dyson
07/29/2025
Research on Cable Laying and Wiring Construction Technology of Photovoltaic Power Station
Research on Cable Laying and Wiring Construction Technology of Photovoltaic Power Station
1 Research on Cable Laying and Wiring Construction Technology of Photovoltaic Power Station1.1 Data CollectionBefore constructing the BIM model for cable laying, it is necessary to deeply master the detailed parameters of the involved equipment specifications, materials used in construction, and site conditions, aiming to improve the accuracy of model construction. To ensure that the BIM model can accurately reflect the actual situation of the construction site, the core lies in accurately colle
Echo
07/29/2025
Cable Detection and Analysis of Integrated Wiring System in Intelligent Buildings
Cable Detection and Analysis of Integrated Wiring System in Intelligent Buildings
The integrated wiring system of intelligent buildings, as the core carrier of information transmission, functions like a "nervous system." It connects signals such as voice, data, and images, enabling device interconnection and efficient information transmission. Cable detection is a key link to ensure system performance and information security, focusing on index detection, problem troubleshooting, and response measures.1. Core Cable Detection Indicators1.1 Appearance and Identification Verific
Oliver Watts
07/29/2025
What are the key points for quality control in the installation of communication cables in protective spaces?
What are the key points for quality control in the installation of communication cables in protective spaces?
In the context of deep integration of informatization and intelligence, protective spaces, as core carriers of critical communication systems, their stability and safety directly impact information transmission reliability and infrastructure operational efficiency. Thus, analyzing core difficulties (environmental adaptability matching, electromagnetic compatibility design, construction precision control) in communication cable installation in protective spaces holds significant engineering value
James
07/29/2025
What are the basic processes and key points in transformer simulation design?
What are the basic processes and key points in transformer simulation design?
1 IntroductionWhether using any finite element analysis software (such as COMSOL, Infolytica, or Ansys) for transformer simulation analysis—whether focusing on electric field, magnetic field, flow field, mechanical field, or acoustic field—the basic process is roughly the same. A true understanding of the key points in each process is the foundation for the success of the simulation analysis and the reliability of the final results.2 Basic Simulation ProcessA scientific and complete
Ron
07/29/2025
Sharing of Transformer Concepts and Terminology
Sharing of Transformer Concepts and Terminology
Sharing of Transformer Concepts and TerminologyThe zero-mode impedance of a load is infinite, and its line-mode impedance is also extremely large, approximately 100 times that of the line-mode impedance of the line.The capacitance to ground of a cable is 25-50 times that of an overhead line.The free oscillation frequency of transient capacitive current: 300-1500Hz for overhead lines and 1500-3000Hz for cables.Performance requirements for an external grounding transformer: Under normal power supp
Edwiin
07/28/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!