• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


New Silicon Steel Sheet Automatic Cut to Length Line Machine for Transformer Lamination Core with Motor PLCS Industrial Use

  • New Silicon Steel Sheet Automatic Cut to Length Line Machine for Transformer Lamination Core with Motor PLCS Industrial Use
  • New Silicon Steel Sheet Automatic Cut to Length Line Machine for Transformer Lamination Core with Motor PLCS Industrial Use
  • New Silicon Steel Sheet Automatic Cut to Length Line Machine for Transformer Lamination Core with Motor PLCS Industrial Use

Key attributes

Brand Wone
Model NO. New Silicon Steel Sheet Automatic Cut to Length Line Machine for Transformer Lamination Core with Motor PLCS Industrial Use
Shearing thickness 0.23-0.35mm
Shearing width 60-640mm
Shearing length 600-3500mm
Weight of material >3000kg
Series SKJ

Product descriptions from the supplier

Description

Features

  • lThe high accuracy of sheet feeding and cutting is guaranteed by precise photoelectric encoder, SIEMENS AC servo drive system and SIMOTION Motion controller. 

  • lCentral positioning for whole line guide width adjustment is controlled by computer.

  • lAdoption of graphic operation terminal with human-machine menu and colored processing pattern display enables operators to complete lamination shapes confirmation and parameters input through the touch screen.

  • lCompensation and achieves rapid adjustment of cutting length.

  • lCutting function and can cut step-lap lamination automatically.

  • lPreset number of sheets can be done automatically.Punching and shearing are driven by high dynamic servomotors, efficient with low noise.

  • lAutomatic stacking is adopted to stack silicon steel sheets from largest to smallest sizes or from smallest to largest sizes.

 Composition

(1). Double head decoiler    (2). Sheet guiding device    (3). Sheet feeder

(4). Punching unit    (5). Shearing unit    (6). Discharge table   (7). Diverting mechanism

(8). Stacking trolley   (9). Control cabinet    (10). Operating console

Specifications

Item

SKJ450

SKJ600

Shearing thickness

0.23-0.35mm

0.23-0.35mm

Shearing width

40-450mm

60-640mm

Shearing length

340-2000mm

600-3500mm

Punching aperture

customized

customized

Feeding speed

240m/min

240m/min

Shear rate (length 1000 mm)

50 piece/min

50 piece/min

Shearing accuracy

±0.1

±0.1

Shearing angel accuracy

±0.01°

±0.01°

Shearing burrs

0.02mm

0.02mm

Outer diameter of coiled material

No more thanφ1000mm

No more thanφ1000mm

Coil I.D.

φ500mm

φ500mm

Weight of material

No more than 1500kg

No more than 3000kg

Spindle telescoping range of decoiler

φ470-φ520mm

φ470-φ520mm

Carried material table height

No more than 200 mm

No more than 300 mm

Discharge direction

Transverse

Transverse

41f079f02aa0afba2393a26d2eeec6e0.jpeg

d5764ac4a5f6f4b369fc089f8a869df8.jpeg

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 65666m²m² Total staff: 300+ Highest Annual Export(usD): 50000000
Workplace: 65666m²m²
Total staff: 300+
Highest Annual Export(usD): 50000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: Wire cable/High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Instrument meters/New energy/Tester/Integrated Electrical Equipment/Production equipment/Generator/Electrical fittings
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Main Transformer Accidents and Light Gas Operation Issues
    1. Accident Record (March 19, 2019)At 16:13 on March 19, 2019, the monitoring background reported a light gas action of No. 3 main transformer. In accordance with the Code for Operation of Power Transformers (DL/T572-2010), operation and maintenance (O&M) personnel inspected the on-site condition of No. 3 main transformer.On-site confirmation: The WBH non-electrical protection panel of No. 3 main transformer reported a Phase B light gas action of the transformer body, and the reset was ineff
    02/05/2026
  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.