• Photovoltaic inverter grid-connected transformers
Photovoltaic inverter grid-connected transformers
discuss personally
Model
SGG/SD-60kVA
SGG/SD-80kVA
SGG/SD-100kVA
SGG/SD-25kVA
Basic info
Brand ROCKWILL
Model NO. Photovoltaic inverter grid-connected transformers
Rated frequency 50/60Hz
Rated capacity 100kVA
Series SGG
Product Detail

Product Overview

An isolated transformer is a double-winding transformer that not only achieves voltage transformation in the power grid but also provides electrical safety isolation between input and output windings. This feature effectively prevents electric shock hazards when the human body comes into simultaneous contact with live components (or metal parts that may become charged due to insulation damage) and the ground. Additionally, it can isolate the third harmonics in the power grid, reduce heat generation during equipment operation, and extend the service life of insulating materials. It also functions to suppress and eliminate interferences such as noise, clutter, high voltage, and surges in the power grid, providing a pure power environment for equipment.

The dry-type photovoltaic transformers produced by our company are special transformers designed for photovoltaic grid-connected inverters. Adopting a foil winding process, the transformer core features a full-joint structure, and the core laminations are made of low-loss oriented silicon steel sheets, offering significant advantages of low loss, high efficiency, and low temperature rise. This series of transformers is suitable for circuits with an AC frequency of 50Hz/60Hz and a rated voltage below 690V, and can be custom-designed and manufactured according to specific user requirements.

Product features

  • Energy-saving and low-noise:High-quality cold-rolled silicon steel sheets are used for stacking; The special dipping process is used to effectively reduce the vibration and noise during operation; As well as the introduction of new processes and technologies such as the design of high-temperature resistant insulation materials, the transformer is more energy-saving and quieter. The coil has a ventilation groove to allow for smooth air flow, effectively reducing the coil temperature.

  • High reliability:The structure is reasonable, the efficiency is high, the waveform is not distorted, it is convenient and reliable to use, it can run for a long time, and the performance indicators fully meet the standard requirements of GB/6450 dry-type power transformer. It can isolate the power supply of the main power grid, anti-shock, anti-interference, and anti-lightning.

  • Eco-friendly features:It has heat resistance, moisture resistance, stability, chemical compatibility, low temperature resistance, radiation resistance and non-toxicity.

  • Versatility:From a single transformer to a multi-functional combined transformer with air cooling, protective housing, transformer and so on.

Model specifications:

Note:The dimensions and technical indicators of the above products can be customized according to customer requirements.

Application scenarios:

SGG/SD series photovoltaic inverter grid-connected transformer is a supporting product of solar photovoltaic, its rated input voltage is AC three-phase 270V, rated output voltage is AC three-phase 400V, rated working frequency is 50/60HZ, it will be the direct current in the solar energy through the photovoltaic inverter inverter out of the three-phase AC 270V voltage isolation and step-up into three-phase AC 400V voltage, in order to be integrated into the grid or directly supply the single-phase 220V and three-phase 380V AC power supply required by users.

 

 

 

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
For users, when purchasing a 35kV new energy transformer, choosing between dry-type, mineral oil-filled, or vegetable oil-filled types involves multiple considerations. These include user habits, maintenance-free performance, safety and fire resistance, volume and weight, among others. However, cost differences are undoubtedly one of the most crucial factors.To illustrate the issue intuitively, this paper selects a three-level energy efficiency dual-winding new energy transformer with a rated ca
Ron
07/26/2025
What is the connection group of a transformer?
What is the connection group of a transformer?
Transformer Connection GroupThe connection group of a transformer refers to the phase difference between the primary and secondary voltages or currents. It is determined by the winding directions of the primary and secondary coils, the labeling of their start and end terminals, and the connection mode. Expressed in a clock-like format, there are 12 groups in total, numbered from 0 to 11.The DC method is commonly used to measure the transformer's connection group, mainly to verify whether the con
Vziman
07/26/2025
Working Voltage in Power System
Working Voltage in Power System
Working VoltageThe term "working voltage" refers to the maximum voltage that a device can withstand without sustaining damage or burning out, while ensuring the reliability, safety, and proper operation of both the device and associated circuits.For long-distance power transmission, the use of high voltage is advantageous. In AC systems, maintaining a load power factor as close to unity as possible is also economically necessary. Practically, heavy currents are more challenging to handle than hi
Encyclopedia
07/26/2025
What is Steady State Stability in Power System?
What is Steady State Stability in Power System?
Definition of Steady State StabilitySteady state stability is defined as the capability of an electric power system to sustain its initial operating condition following a small disturbance, or to converge to a state closely approximating the initial condition when the disturbance persists. This concept holds critical significance in power system planning and design, the development of specialized automatic control devices, the commissioning of new system components, and the adjustment of operati
Edwiin
07/26/2025
What is the sequence for powering down the transformer?
What is the sequence for powering down the transformer?
The sequence for shutting down a main transformer is as follows: when de-energizing, the load side should be shut down first, followed by the power supply side. For energizing operations, the reverse order applies: the power supply side is energized first, then the load side. This is because: Energizing from the power supply side to the load side makes it easier to identify the fault range and take prompt judgment and handling measures in case of a fault, preventing the fault from spreading or e
Rockwell
07/26/2025
What are the methods for switching operations of station transformers?
What are the methods for switching operations of station transformers?
Let's take an auxiliary power system with two station transformers as an example. When one station transformer needs to be out of service, there are two operation methods: non-interruptive power supply and instantaneous power interruption. Generally, the method of instantaneous power interruption on the low-voltage side is preferred.The operation method for instantaneous power interruption on the low-voltage side is as follows:Open the 380V power incoming circuit breaker of the corresponding sec