Transformer foil winding machine

  • Transformer foil winding machine

Key attributes

Brand Switchgear parts
Model NO. Transformer foil winding machine
Winding speed 0-30(rpm)
Tension 8KN
Width of foil 150-700mm
Outer diameter of coil 150-600mm
Thickness of foul(AL) 0.5-2.0mm
Thickness of foul(Cu) 0.5-1.6mm
Welding speed ≤0.5m/min
Offset regulating accuracy ±0.5
Series BRJ

Product descriptions from the supplier

Description

Application

Transformer Coil Winding Machine is an automated specialized equipment designed for transformer foil coils. It uses copper foil or aluminum foil as the winding conductor, and is synchronously wound with insulation paper to form a layered structure of transformer coils.
The core configuration of the equipment includes a precision tension control system, an automatic interlayer insulation feed mechanism, and a PLC programmable control system, which can achieve integrated operations of foil feeding, positioning, cutting, and insulation layer laying, ensuring the compactness, flatness, and turn accuracy of coil winding. It is suitable for foil and insulation materials of different widths and has both semi-automatic and fully automatic operation modes, meeting the dual needs of small batch customization and large-scale production. Types of compatible transformers: dry-type transformers, oil immersed distribution transformers, power transformers, special transformers, etc

Features

Tension is stable during operation

Offset regulating system for high efficiency

Foil tension, insulation tension adjustable and stable

Video monitoring for foil shearing

Material feeding easily

Optional for cold press welding

Specifications

Parameter

BRJ(S1)-700

BRJ(S1)--1000

BRJ(S2)--1000

BRJ(S2)--1400

Width of foil (mm)

150--700

300--1000

300--1000

500--1400

Outer diameter of coil (mm)

150--600

200--800

Thickness of foul(AL) (mm)

0.5--2.0

Thickness of foul(Cu) (mm)

0.5--1.6

Winding speed (rpm)

0--30

0--30

0--30

0--20

Max. tension (KN )

8

10

10

20

Welding mode

TIG / Cold press welding

Welding speed (m/min)

≤0.5

Offset regulating accuracy (mm)

±0.5

 

Documentation Resource Library
Public.
Foil winding machine
Catalogue
English
FAQ
Q: What are the operation and auxiliary functions of this foil winding machine, and how do these functions improve production efficiency and operational convenience?
A:

The core operations and auxiliary functions include convenient feeding, video monitoring of foil cutting, and optional cold press welding (compatible with TIG welding). The function is as follows: 1 The convenient feeding function simplifies the material loading process, reduces manual operation time, lowers labor intensity, and improves material replacement efficiency; 2. Video monitoring of foil cutting allows real-time observation of the cutting process, timely detection of abnormalities such as burrs and uneven cuts, avoiding unqualified materials from entering the winding process and reducing subsequent rework costs; 3. The optional welding function does not require the additional configuration of specialized welding equipment, realizing the integrated operation of "winding welding", shortening the production process, and being compatible with two welding modes, adapting to the connection requirements of different materials of foil, improving the universality and production continuity of the equipment.

Q: There are four models of this device, and what are the differences in core parameters between different models? How should enterprises select based on production needs?
A:

The core parameter differences of different models are concentrated in three key indicators: foil width, maximum tension, and winding speed (specific differences: ① BRJ (S1) --700: foil width 150-700mm, maximum tension 8KN, speed 0-30rpm; ② BRJ (S1) --1000: foil width of 300-1000mm, maximum tension of 10KN; ③ BRJ (S2) -1000: maximum tension of 10KN; ④ BRJ (S2) -1400: foil width of 500-1400mm, maximum tension of 20KN, speed of 0-20rpm). Selection suggestion: ① Small size coils (foil width ≤ 700mm, light tension requirement): choose BRJ (S1) --700, high-speed (0-30rpm) suitable for small batch high-efficiency production; ② Medium size coil (foil width ≤ 1000mm): choose BRJ (S1) --1000 or BRJ (S2) -1000, 10KN tension suitable for conventional aluminum/copper foil processing; ③ Large size coil (foil width ≤ 1400mm, heavy tension requirement): Choose BRJ (S2) -1400, 20KN high tension can adapt to thicker or wider foil materials, meeting the processing requirements of large low-voltage coils.

Q: What are the core technological advantages of this foil winding machine, and how do these advantages ensure the processing quality of transformer low-voltage coils?
A:

Answer: The core technological advantages include stable operating tension, adjustable and stable foil and insulation tension, and offset adjustment system (accuracy ± 0.5mm). Quality assurance logic: 1 Stable tension can avoid problems such as looseness and uneven stretching during foil winding, ensuring a dense coil structure; 2. The dual tension adjustable function can accurately adjust the tension parameters according to the different material characteristics of aluminum foil (0.5-2.0mm) and copper foil (0.5-1.6mm), as well as the requirements of insulation materials, to avoid material damage; 3. The offset adjustment system can accurately control the alignment accuracy of the foil material, prevent the risk of short circuit between coil layers caused by misalignment, and ultimately ensure the electrical performance and structural stability of the low-voltage coil.

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: Highest Annual Export(usD): 300000000
Workplace: 1000m²
Total staff:
Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: Low Voltage Electrical Apparatus/Instrument meters/Production equipment/Tester/High Voltage Electrical Apparatus/Electrical fittings/Equipment Parts
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
  • What’s the Difference Between Rectifier Transformers and Power Transformers?
    What is a Rectifier Transformer?"Power conversion" is a general term encompassing rectification, inversion, and frequency conversion, with rectification being the most widely used among them. Rectifier equipment converts input AC power into DC output through rectification and filtering. A rectifier transformer serves as the power supply transformer for such rectifier equipment. In industrial applications, most DC power supplies are obtained by combining a rectifier transformer with rectifier equ
    01/29/2026
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now