Ultra thin Wall-Mounted DC Charger

  • Ultra thin Wall-Mounted DC Charger

Key attributes

Brand RW Energy
Model NO. Ultra thin Wall-Mounted DC Charger
Rated voltage 3*230(400)V
Rated normal current 80A
Rated Output Rating 30KW
Connector Options GBT
Series WZ15W

Product descriptions from the supplier

Description

Product Overview

Tailored for home garages, community parking lots, commercial premises, and small fleet operations, this charger offers 20kW/30kW dual power options. With wall-mounted compact design (600mm x 470mm x 100mm, 25kg/28kg), it saves floor space. Supporting GBT, CCS1/CCS2, CHAdeMO, Tesla, NACS standards, it's compatible with most new energy vehicles. Air-cooled, -30°C~75°C operating temperature, low failure rate, and simple operation ensure cost-effective, efficient charging for personal, commercial, and fleet use.

Key Features

  • Dual Power & Efficient Charging: 20kW/30kW options, nominal efficiency ≥94%, meeting daily/short-distance charging needs.

  • Compact Wall-Mounted Design: Slim size, lightweight, ideal for space-limited scenarios.

  • Easy Installation & Operation: No complex construction; 2s long press to start, brief press to auto-shut down after 2s.

  • Full-Standard Compatibility: Complies with GBT, ISO 15118, CHAdeMO 1.2/2.0, NACS, etc., no adapters needed.

  • Reliable Operation: Optimized hardware, air-cooled heat dissipation, adapting to -30°C~75°C harsh environments.

  • Low Noise: <65db, ensuring quiet charging in home/commercial scenarios.

  • Customizable Cable: 3.5m/5m/7m optional, improving convenience.

  • High Safety: Over-voltage/under-voltage/over-current/short-circuit protection; insulation >2.5kV.

Technical Parameters

Product Model

WZ-20kW

WZ-30kW

Input Voltage

380VAC (3P+N+PE), 50Hz

Output Voltage

200-750VDC

Output Current (default)

50A (37A for CHAdeMO)

80A

Gun Muzzle Standard

GBT/CCS1/CCS2/CHAdeMO/Tesla

Charging Module

20kW

30kW

Efficiency

≥94% (nominal output)

Power Factor

>0.98

Operating Temperature

-30°C to 75°C

Altitude

<3000m

Humidity (Working/Storage)

≤95% RH / ≤99% RH (Non-condensing)

AC Input Cable & Switch

36mm2+24mm2 1m 40A / 310mm2+26mm2; 1m 63A

Weight

25kg / 28kg

Dimensions (LxDxH)

600mmx470mmx100mm

Installation

Wall-mounted

Startup/Shutdown Mode

2s long press to start; brief press (auto-off after 2s)

Cooling

Air Cooled

Charging Cable Length

3.5m/5m/7m (Optional)

Noise

<65db

Ingress Protection

IP30

Insulation (Input-Output)

>2.5kV

Electrical Safety

Over-voltage/under-voltage/over-current/short-circuit protection

Application Scenarios

  1. Home Garage: Wall-mounted installation saves space; overnight full charge meets daily commuting needs.

  2. Community Charging Points: Shared facilities, multi-standard compatibility, low maintenance cost for residents.

  3. Commercial Premises: Value-added service for customers/employees; small footprint fits limited parking areas.

  4. Small Fleet Charging: Suitable for 5-10-vehicle fleets; flexible power options, efficient multi-vehicle charging.

  5. Homestay/Hotel: Enhances accommodation competitiveness; easy installation, compatible with various vehicle brands.

  6. Temporary Outdoor Charging: Lightweight and portable, providing stable power for outdoor operation vehicles.

Documentation Resource Library
Public.
High-performers fast charger selection catalog
Catalogue
English
FAQ
Q: What payment methods does the product support? Is it suitable for commercial operation?
A:

RFID card swiping is standard across the entire range (ISO/IEC 14443A/B); All products in the series that support the OCPP 1.6 protocol can be integrated with commercial platforms to meet operational needs.

 

Q: How does the conversion efficiency and power factor of the product generally perform?
A:

Peak efficiency ≥ 96%; The power factor is all>0.98, with low energy loss.

 

Q: As a household appliance, which device should I choose?
A:

WZ15L (40/60kW) focuses on medium to high power, while WZ15W (20/30kW) emphasizes lightweight and portable installation. When space is extremely limited, choose WZ-15W, which does not occupy ground space. If there is ample space, choose WZ-15L to improve charging efficiency.

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 30000m² Total staff: Highest Annual Export(usD): 100000000
Workplace: 30000m²
Total staff:
Highest Annual Export(usD): 100000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Instrument meters/New energy/Tester/Robot
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
  • What’s the Difference Between Rectifier Transformers and Power Transformers?
    What is a Rectifier Transformer?"Power conversion" is a general term encompassing rectification, inversion, and frequency conversion, with rectification being the most widely used among them. Rectifier equipment converts input AC power into DC output through rectification and filtering. A rectifier transformer serves as the power supply transformer for such rectifier equipment. In industrial applications, most DC power supplies are obtained by combining a rectifier transformer with rectifier equ
    01/29/2026

Related Solutions

  • Distribution automation systems solutions
    What are the difficulties in overhead line operation and maintenance?Difficulty one:Overhead lines of distribution network have wide coverage,complicatedterrain,many radiation branches and distributed power supply,resultingin "many line faults and difficulty in fault troubleshooting".Difficulty Two:Manual troubleshooting is time-consuming and laborious.Meanwhile,therunning current,voltage and switching state of the line cannot be graspedin real time,because of the lack of intelligent technical m
    04/22/2025
  • RW8000 DMS Distribution Management System Solutions
    OverviewNowadays, the development trend of power grid is intellectualization. As an important part of power grid, the power distribution system is very close to the customers and it has to run properly. The distribution management system (DMS)played an important role in it.Introduction:RW8000 power distribution management system (DMS) is designed for the smart grids. It is based on real-time application, centered on distribution network operation and management, focusing on the business process
    09/07/2023
  • High-Precision Electrical Parameter Monitoring System Solution
    1.Introduction​With the increasingly stringent requirements for power supply quality in high-end facilities such as precision manufacturing, medical diagnosis, and data centers, traditional power monitoring systems, due to their low sampling accuracy and weak data analysis capabilities, can no longer meet the demand for deep insight and precise management of power quality. In response, we are introducing a new generation ​High-Precision Electrical Parameter Monitoring System. With ​millisecond-l
    09/28/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.