• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


Vehicle-to-Vehicle DC Charger

  • Vehicle-to-Vehicle DC Charger
  • Vehicle-to-Vehicle DC Charger

Key attributes

Brand RW Energy
Model NO. Vehicle-to-Vehicle DC Charger
Rated voltage DC 800V
Rated normal current 32A
Rated Output Rating 20kW
Connector Options GBT
Series WZ-V2V

Product descriptions from the supplier

Description

Product Overview

This V2V DC charger enables direct DC charging between new energy vehicles, breaking the reliance on fixed stations. It solves range anxiety in emergencies like sudden power outages during long trips or remote area breakdowns. Compatible with CCS1/CCS2/CHAdeMO/GBT/Tesla standards (no adapters needed), it features a compact, portable design (<40kg, 550mm x 260mm x 400mm) for easy storage in vehicle trunks, suitable for personal emergency, fleet support, and outdoor travel.

Key Features

  • Vehicle-to-Vehicle Direct Charging: Rapid energy transmission for power-off vehicles, timely rescue.

  • Full Multi-Standard Compatibility: Covers global mainstream protocols, compatible with most new energy vehicle brands.

  • Ultra-Portable: Lightweight (<40kg) and compact, easy to carry and store.

  • Customizable Cable Length: 2.5m/3.5m/5m optional, improving operational convenience.

  • High-Efficiency Conversion: Full-load efficiency >95.5%, low energy loss.

  • Long Battery Life: Built-in battery lasts over 20 hours, auto-charging during use with 12.6V charger.

  • Simple Operation: 7-inch display, one-click startup, no professional technical background required.

Technical Parameters

Category

Data Parameters

Working Environment

Working temperature: -40℃~+75℃; Cooling: Air cooling; Altitude: ≤5000m

Charging Input

Voltage/current: 260Vdc~900Vdc; 0.2~34A; Connector: CCS1/CCS2/GBT/CHAdeMO/Tesla (Optional)

Charging Output

Rated power: 20kW; 

Voltage/current: 50Vdc~750Vdc; 0.2~50A;

Stabilization accuracy: Voltage ≤±0.5%, Current ≤±1% (20%~100% load); 

Connector: Same as input (Optional)

Safety Protection

Input over/under voltage, output overvoltage, overcurrent, short circuit, over temperature protection

Startup Method

One-click on 7-inch display

Internal Battery

>20 hours battery life, auto-charging; 12.6V portable charger included

Size

Shell: 550mm x 260mm x 400mm; Packaging: 650mm x 360mm x 750mm

Weight

Net weight <40kg; Gross weight <42kg

Protection Level

IP43

Cable Length

2.5m/3.5m/5m (Optional)

Application Scenarios

  1. Personal Long-Distance Emergency: Replenishes power from accompanying vehicles in remote areas, avoiding road rescue waits.

  2. Fleet Operation Support: Mutual charging between fleet vehicles, no detour to fixed stations, improving operational efficiency.

  3. Outdoor Off-Grid Power: Mutual vehicle charging and power supply for small devices (camping lights, refrigerators), enhancing outdoor comfort.

  4. Urban Roadside Rescue: On-site charging for power-off vehicles, reducing towing costs and waiting time.

  5. Remote Operation Vehicle Supplementary Energy: Mutual charging for engineering/mining/distribution vehicles in areas without fixed charging facilities.

  6. Exhibition/Test Drive Support: Flexible mobile charging for multiple models, ensuring sufficient power for displays/tests.

 

Documentation Resource Library
Public.
High-performers fast charger selection catalog
Catalogue
English
FAQ
Q: How portable is the device? Is storage and transportation convenient?
A:

Lightweight design, with a bare weight of less than 24kg, detachable charging cable and gun head, and a total weight of only 3.15kg, making it easy to carry and store with the vehicle; Compact in size, it can be quickly transported and deployed during road rescue without taking up too much space.

Q: What are the core advantages of this V2V charger compared to ordinary powered devices?
A:

By adopting DC fast charging technology, the charging process will be protected, and the charging speed will reach the maximum power of the discharge vehicle itself, resulting in higher efficiency and lower losses; It can quickly replenish the range of vehicles with low battery life, adapt to outdoor emergency, road rescue and other scenarios, rather than just starting the vehicle.

Q: Do we need to rely on external power sources? Can it be used without the power grid?
A:

No need to rely on the power grid, fully powered by mutual charging of two vehicle batteries; The entire process relies on electric vehicles for energy storage, suitable for outdoor, remote road sections and other emergency scenarios without power grids.

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 30000m² Total staff: Highest Annual Export(usD): 100000000
Workplace: 30000m²
Total staff:
Highest Annual Export(usD): 100000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Instrument meters/New energy/Tester/Robot
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
  • What’s the Difference Between Rectifier Transformers and Power Transformers?
    What is a Rectifier Transformer?"Power conversion" is a general term encompassing rectification, inversion, and frequency conversion, with rectification being the most widely used among them. Rectifier equipment converts input AC power into DC output through rectification and filtering. A rectifier transformer serves as the power supply transformer for such rectifier equipment. In industrial applications, most DC power supplies are obtained by combining a rectifier transformer with rectifier equ
    01/29/2026

Related Solutions

  • Distribution automation systems solutions
    What are the difficulties in overhead line operation and maintenance?Difficulty one:Overhead lines of distribution network have wide coverage,complicatedterrain,many radiation branches and distributed power supply,resultingin "many line faults and difficulty in fault troubleshooting".Difficulty Two:Manual troubleshooting is time-consuming and laborious.Meanwhile,therunning current,voltage and switching state of the line cannot be graspedin real time,because of the lack of intelligent technical m
    04/22/2025
  • RW8000 DMS Distribution Management System Solutions
    OverviewNowadays, the development trend of power grid is intellectualization. As an important part of power grid, the power distribution system is very close to the customers and it has to run properly. The distribution management system (DMS)played an important role in it.Introduction:RW8000 power distribution management system (DMS) is designed for the smart grids. It is based on real-time application, centered on distribution network operation and management, focusing on the business process
    09/07/2023
  • High-Precision Electrical Parameter Monitoring System Solution
    1.Introduction​With the increasingly stringent requirements for power supply quality in high-end facilities such as precision manufacturing, medical diagnosis, and data centers, traditional power monitoring systems, due to their low sampling accuracy and weak data analysis capabilities, can no longer meet the demand for deep insight and precise management of power quality. In response, we are introducing a new generation ​High-Precision Electrical Parameter Monitoring System. With ​millisecond-l
    09/28/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.