• 420kV HV gas insualted Switchgear(GIS)
420kV HV gas insualted Switchgear(GIS)
discuss personally
Model
ZF28-420/4000-63
Basic info
Brand ROCKWILL
Model NO. ZF28-420 TYPE SF6 GAS INSULATED SWITCHGEAR
Rated voltage 420kV
Rated normal current 4000A
Series ZF28
Product Detail

Product overview:
    ZF28-420 type GIS is composed of standard modules through flanged joint, which can meet the demand for substation optimization design through the flexible combination between modules. It saves space and conforms to technical requests.
    This product can be applied to power system, power generation, rail transportation, petrochemical, metallurgy, mining, building materials and other large industrial consumer.

Features and advantages of the product:

  • Horizontal circuit breaker structure, integrated transportation, high space utilization.

  • Fusion of high parameters and high reliabilityCircuit breaker, disconnector and grounding switch have a mechanical life of 10,000 times.

  • Advanced circuit breaker, excellent breaking capacity.

  • Mature pure spring operating mechanism application.

  • Basin insulator with aluminum flange with double seal structure.

  • Import of key components, accessories and major production equipment.

  • The GIS phase spacing is 670mm and the standard spacing width is 2050mm (see layout). The whole interval of three-phase integrated transportation, its technological innovation level is domestic leading, international advanced level.

  •  Arrangement of circuit breaker is horizontal, it’s convenient for overhauling and emergency maintenance; it also will make lighter impact to the ground.

  • Excellent insulation level and low partial discharge. The only company in the industry that can achieve: under  1.2 times phase voltage (1.2×420/√3 = 291kV), the partial discharge of intervals is lower than 5pC, the partial discharge of the insulator is lower than 3pC.

Technical Parameters:

ZF28-420 GIS .png

What is a GIS device?

GIS is the English abbreviation of Gas Insulated Switchgear, which is generally translated as gas-insulated fully enclosed combined electrical appliances, usually using SF6 gas as the insulating medium, including circuit breaker (CB), disconnector (DS), earthing switch (ES, FES), bus (BUS), current transformer (CT), voltage transformer (VT), lightning arrester (LA) and other high-voltage components. At present, GIS equipment products have covered the voltage level range of 72.5 kV ~ 1200 kV.


Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
For users, when purchasing a 35kV new energy transformer, choosing between dry-type, mineral oil-filled, or vegetable oil-filled types involves multiple considerations. These include user habits, maintenance-free performance, safety and fire resistance, volume and weight, among others. However, cost differences are undoubtedly one of the most crucial factors.To illustrate the issue intuitively, this paper selects a three-level energy efficiency dual-winding new energy transformer with a rated ca
Ron
07/26/2025
What is the connection group of a transformer?
What is the connection group of a transformer?
Transformer Connection GroupThe connection group of a transformer refers to the phase difference between the primary and secondary voltages or currents. It is determined by the winding directions of the primary and secondary coils, the labeling of their start and end terminals, and the connection mode. Expressed in a clock-like format, there are 12 groups in total, numbered from 0 to 11.The DC method is commonly used to measure the transformer's connection group, mainly to verify whether the con
Vziman
07/26/2025
Working Voltage in Power System
Working Voltage in Power System
Working VoltageThe term "working voltage" refers to the maximum voltage that a device can withstand without sustaining damage or burning out, while ensuring the reliability, safety, and proper operation of both the device and associated circuits.For long-distance power transmission, the use of high voltage is advantageous. In AC systems, maintaining a load power factor as close to unity as possible is also economically necessary. Practically, heavy currents are more challenging to handle than hi
Encyclopedia
07/26/2025
What is Steady State Stability in Power System?
What is Steady State Stability in Power System?
Definition of Steady State StabilitySteady state stability is defined as the capability of an electric power system to sustain its initial operating condition following a small disturbance, or to converge to a state closely approximating the initial condition when the disturbance persists. This concept holds critical significance in power system planning and design, the development of specialized automatic control devices, the commissioning of new system components, and the adjustment of operati
Edwiin
07/26/2025
What is the sequence for powering down the transformer?
What is the sequence for powering down the transformer?
The sequence for shutting down a main transformer is as follows: when de-energizing, the load side should be shut down first, followed by the power supply side. For energizing operations, the reverse order applies: the power supply side is energized first, then the load side. This is because: Energizing from the power supply side to the load side makes it easier to identify the fault range and take prompt judgment and handling measures in case of a fault, preventing the fault from spreading or e
Rockwell
07/26/2025
What are the methods for switching operations of station transformers?
What are the methods for switching operations of station transformers?
Let's take an auxiliary power system with two station transformers as an example. When one station transformer needs to be out of service, there are two operation methods: non-interruptive power supply and instantaneous power interruption. Generally, the method of instantaneous power interruption on the low-voltage side is preferred.The operation method for instantaneous power interruption on the low-voltage side is as follows:Open the 380V power incoming circuit breaker of the corresponding sec
Vziman
07/26/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!