• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


Free Expert Guides on Power Systems, Circuit Design & Electrical Troubleshooting

Access free engineering resources from IEE Business—covering power design, circuit layout, equipment selection, and troubleshooting. Expert-developed guides help engineers, procurement, and project teams make better decisions. Stay ahead on smart grids, renewables, efficiency, and AI tools. Improve reliability, reduce downtime, and enhance outcomes with real-world solutions. Explore our knowledge hub today.
126(145)kV Vacuum Circuit Breaker Installation & Adjustment Guide
High-voltage vacuum circuit breakers, owing to their excellent arc-quenching characteristics, suitability for frequent operation, and long maintenance-free intervals, have been widely applied in China’s power industry—particularly in urban and rural power grid upgrades, as well as in chemical, metallurgical, railway electrification, and mining sectors—and have received widespread acclaim from users.The primary advantage of vacuum circuit breakers lies in the vacuum interrupter. However, the char
11/20/2025
Consult
Tip
Consult
Tip
Abnormal Operation and Handling of High-Voltage Circuit Breakers and Disconnectors
Common Faults of High-Voltage Circuit Breakers and Mechanism Pressure LossCommon faults of high-voltage circuit breakers themselves include: failure to close, failure to trip, false closing, false tripping, three-phase asynchronism (contacts not closing or opening simultaneously), damage to the operating mechanism or pressure drop, oil spraying or explosion due to insufficient interrupting capacity, and phase-selective circuit breakers failing to operate according to the commanded phase."Circuit
11/14/2025
Consult
Tip
Consult
Tip
What are the common faults of 35kV high-voltage circuit breakers?
High-Voltage Circuit Breakers: Common Faults and Solutions for 35kV SystemsHigh-voltage circuit breakers are critical electrical equipment in power substations. A thorough understanding of their fault patterns and root causes enables targeted troubleshooting, rapid power restoration, and effective reduction of losses caused by outages and equipment damage.I. Common Operational Faults of 35kV High-Voltage Circuit Breakers1. Failure to Store Energy (Charging Failure)Energy storage is the foundatio
10/16/2025
Consult
Tip
Consult
Tip
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.