Why are copper losses typically lower than iron losses in an ideal transformer?

Encyclopedia
12/03/2024

The copper loss and iron loss in an ideal transformer

In the theoretical model of an ideal transformer, we assume that there are no losses, which means both copper loss and iron loss are zero. However, if we consider an ideal transformer from a more realistic perspective, we can argue that its copper loss and iron loss should theoretically be very low. Specifically, the copper loss of an ideal transformer is usually considered lower than its iron loss, mainly due to several reasons:

  • Definition of Copper Loss: Copper loss is the energy loss that occurs due to the resistance of transformer windings (typically copper conductors) when current flows through them. According to Joule's Law, heat is generated, and this portion of energy loss is referred to as copper loss.

  • Definition of Iron Loss: Iron loss consists of eddy current loss and hysteresis loss generated by the transformer iron core in an alternating magnetic field. Even under ideal conditions, these losses still exist due to the inherent characteristics of the iron core material.

  • Ideal Performance: In an ideal transformer, the winding resistance can be considered infinitely small, resulting in negligible copper loss. However, iron loss still exists as it is related to the properties of the core material and the action of the alternating magnetic field, which cannot be completely eliminated, even in an ideal scenario.

Copper and Iron Losses in Actual Transformers

In practical transformers, the situation is different. While we can minimize losses by using high-quality materials and advanced designs, copper losses and iron losses are inevitable. Here are some characteristics of copper and iron losses in actual transformers:

  • The Actual Impact of Copper Loss: In practical transformers, copper loss is caused by the resistance of windings and is directly proportional to the square of the current. This means that as load increases and current rises, copper loss also significantly increases.

  • Actual Impact of Iron Losses: The actual iron losses in transformers include eddy current losses and hysteresis losses. Eddy current losses are caused by the production of eddy currents in the iron core due to the alternating magnetic field, while hysteresis losses result from the energy loss in the iron core material during the repeated magnetization and demagnetization process.

  • Comparing Copper Loss and Iron Loss: In practical transformers, the specific values of copper loss and iron loss depend on various factors, including transformer design, load conditions, operating frequency, etc. In some cases, copper loss may exceed iron loss, while in other situations, iron loss may be greater. Typically, for transformers under light load or no-load conditions, iron loss may prevail, whereas for transformers under heavy load conditions, copper loss may be more significant.

Conclusion

In summary, the copper loss in an ideal transformer is typically lower than the iron loss, as the copper loss can theoretically approach zero, while the iron loss cannot be completely eliminated due to the properties of the iron core material. In practical transformers, both copper and iron losses exist, and their specific values depend on various factors. The importance of copper and iron losses may vary under different operating conditions.

Encyclopedia

The Electricity Encyclopedia is dedicated to accelerating the dissemination and application of electricity knowledge and adding impetus to the development and innovation of the electricity industry.

Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
For users, when purchasing a 35kV new energy transformer, choosing between dry-type, mineral oil-filled, or vegetable oil-filled types involves multiple considerations. These include user habits, maintenance-free performance, safety and fire resistance, volume and weight, among others. However, cost differences are undoubtedly one of the most crucial factors.To illustrate the issue intuitively, this paper selects a three-level energy efficiency dual-winding new energy transformer with a rated ca
Ron
07/26/2025
What is the connection group of a transformer?
What is the connection group of a transformer?
Transformer Connection GroupThe connection group of a transformer refers to the phase difference between the primary and secondary voltages or currents. It is determined by the winding directions of the primary and secondary coils, the labeling of their start and end terminals, and the connection mode. Expressed in a clock-like format, there are 12 groups in total, numbered from 0 to 11.The DC method is commonly used to measure the transformer's connection group, mainly to verify whether the con
Vziman
07/26/2025
What is the sequence for powering down the transformer?
What is the sequence for powering down the transformer?
The sequence for shutting down a main transformer is as follows: when de-energizing, the load side should be shut down first, followed by the power supply side. For energizing operations, the reverse order applies: the power supply side is energized first, then the load side. This is because: Energizing from the power supply side to the load side makes it easier to identify the fault range and take prompt judgment and handling measures in case of a fault, preventing the fault from spreading or e
Rockwell
07/26/2025
What are the methods for switching operations of station transformers?
What are the methods for switching operations of station transformers?
Let's take an auxiliary power system with two station transformers as an example. When one station transformer needs to be out of service, there are two operation methods: non-interruptive power supply and instantaneous power interruption. Generally, the method of instantaneous power interruption on the low-voltage side is preferred.The operation method for instantaneous power interruption on the low-voltage side is as follows:Open the 380V power incoming circuit breaker of the corresponding sec
Vziman