• 40.5kV HV Vacuum SF6 circuit breaker
40.5kV HV Vacuum SF6 circuit breaker
discuss personally
Model
ZW39-40.5/2500-31.5
ZW39-40.5/2000-31.5
Basic info
Brand Wone
Model NO. 40.5kV HV Vacuum SF6 circuit breaker
Rated voltage 40.5kV
Rated normal current 2500A
Rated frequency 50Hz
Rated short circuit breaking current 31.5kA
Series ZW39-40.5
Product Detail

Product introduction:

ZW39-40.5 vacuum circuit breaker is applicable in the 50Hz,40,5kV three-0hase electrical system and it is used forbreaking rated current, failure current or switching lines and realize the control and protection of electrical system,This product can be frequently operated and can also be used as a connection breaker.

Main characteristic:

  • The optimized choice of vacuum interrupter contact materials keeps the breaking interception value under 4A on average, effectively inhibiting operation overvoltage.

  •  The circuit breaker has strong breaking capacity and the breaking short-circuit current 31.5kV can reach 30 times.

  •  Equipped with CT34 improved spring operating mechanism, using cast aluminum base, good stability, mechanical life of more than 10000 times. Main features of CT34 improved structure (compared with original CT10A structure).

    (a)The energy storage system adopts floating tooth structure. After closing, the remaining energy of the closing spring will continue to store energy and act as the closing buffer. There is no void, the energy storage time is short, and the energy storage can be in place within 8S;

    (b)Operating mechanism adopts high strength cast aluminum frame, which has high strength, no welding stress and nigh anti-corrosion performance;

    (c)The opening and closing spring and buffer are arranged in a centralized way, with compact structure and beautiful appearance;

    (d)Imported Krupp NB52 grease is used for the mechanism, which is resistant to low temperature and not easy to harden, and is suitable for -50℃~+55°℃ area;

    (e)The mechanism adopts oil buffer, small operation impact, small brake rebound.

  •  This product can meet the environment requirements for a sea level of up to 3000m; with a high insulation level, the insulation level at broken sections reaches 118kV;

  • The circuit breaker may have internally or externally attached transformers. Four internally attached transformers can be attached to each phase of the circuit beaker and the iron core of the internally attached transformer adopts microcrystal alloy and magnetic material with high conductivity, and the electrical transformers above 200A can reach Grade 0.2 or Grade0.2S. The integrated structure of the circuit breaker is compact, and the binding techniques for the secondary windings of transformers have been fully optimized, which fully ensures that after binding the coils of the transformer has regular shape, free of burrs, and they will not become loosen at baking and not deformed after they are installed into the main unit, thus ensuring even electrical field.

  •  The internally attached CT of the circuit breaker is compact, but due to the limited space inside the circuit breaker, it cannot realize very high accuracies (for example 0.2 or 0.2s. ) at small currents (such as those below 100A), and it also has small load. ln addition, the maintenance, capacity increase and replacement of internally attached current transformer is not convenient compared with those of the externally attached transformer.

  •  In the space between the vacuum interrupter and the ceramic sleeve of this product is filled with SF6 gas (without internally attached CT: 0.02MPa, with internally attached CT: 0.2pa), ensuring that no internal condensation and moisture absorption will occur,

  •  Imported products or products made by joint venture manufacturers were adopted for major secondary electric components, so they feature high reliability.

  • The surface treatments for the exposed parts of this product were al hot dip galvanized or directly use high quality stainless steel plates, which feature excellent corrosion resistance.

Main technical parameters:

1732503263140.png

Order notice :

  • Types and specifications of circuit breakers;

  • Rated electrical parameters (voltage, current and breaking current, etc.);

  • Ambient conditions (ambient temperatures, sea levels and grades of environmental pollution level);

  • Operating voltage and motor voltage of operating mechanism;

  • Number, current ratios, scale order combination and secondary load of internally or externally attached transformer;

  •  Spare parts and specialized tools, names and quantity of equipment (need to be ordered separately).

How does a vacuum SF6 circuit breaker work?

Closing Process:

  • Closing Process: When the operating mechanism receives a closing command, it drives the moving contact towards the stationary contact until they make contact and close tightly, thus completing the circuit. During the closing process, the contact pressure between the contacts must reach a certain value to ensure good electrical conductivity and mechanical stability, preventing issues such as overheating and loosening of the contacts during operation.

Opening Process:

  • Opening Process: During the opening process, the operating mechanism rapidly moves the moving contact away from the stationary contact, creating an arc between the contacts. At this point, the insulating medium in the arc quenching chamber (such as sulfur hexafluoride gas) rapidly decomposes and ionizes under the high temperature of the arc, forming a plasma. The positive and negative ions in the plasma move in opposite directions under the influence of the electric field, causing the arc to cool and stretch, ultimately leading to its extinction and the disconnection of the circuit.


Know your supplier
Wone
Main Categories
High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$50,000,000
Professional Experience
1 years
Workplace
65666m²m²
占位
占位
Related Products
Related Knowledges
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
For users, when purchasing a 35kV new energy transformer, choosing between dry-type, mineral oil-filled, or vegetable oil-filled types involves multiple considerations. These include user habits, maintenance-free performance, safety and fire resistance, volume and weight, among others. However, cost differences are undoubtedly one of the most crucial factors.To illustrate the issue intuitively, this paper selects a three-level energy efficiency dual-winding new energy transformer with a rated ca
Ron
07/26/2025
What is the connection group of a transformer?
What is the connection group of a transformer?
Transformer Connection GroupThe connection group of a transformer refers to the phase difference between the primary and secondary voltages or currents. It is determined by the winding directions of the primary and secondary coils, the labeling of their start and end terminals, and the connection mode. Expressed in a clock-like format, there are 12 groups in total, numbered from 0 to 11.The DC method is commonly used to measure the transformer's connection group, mainly to verify whether the con
Vziman
07/26/2025
Working Voltage in Power System
Working Voltage in Power System
Working VoltageThe term "working voltage" refers to the maximum voltage that a device can withstand without sustaining damage or burning out, while ensuring the reliability, safety, and proper operation of both the device and associated circuits.For long-distance power transmission, the use of high voltage is advantageous. In AC systems, maintaining a load power factor as close to unity as possible is also economically necessary. Practically, heavy currents are more challenging to handle than hi
Encyclopedia
07/26/2025
What is Steady State Stability in Power System?
What is Steady State Stability in Power System?
Definition of Steady State StabilitySteady state stability is defined as the capability of an electric power system to sustain its initial operating condition following a small disturbance, or to converge to a state closely approximating the initial condition when the disturbance persists. This concept holds critical significance in power system planning and design, the development of specialized automatic control devices, the commissioning of new system components, and the adjustment of operati
Edwiin
07/26/2025
What is the sequence for powering down the transformer?
What is the sequence for powering down the transformer?
The sequence for shutting down a main transformer is as follows: when de-energizing, the load side should be shut down first, followed by the power supply side. For energizing operations, the reverse order applies: the power supply side is energized first, then the load side. This is because: Energizing from the power supply side to the load side makes it easier to identify the fault range and take prompt judgment and handling measures in case of a fault, preventing the fault from spreading or e
Rockwell
07/26/2025
What are the methods for switching operations of station transformers?
What are the methods for switching operations of station transformers?
Let's take an auxiliary power system with two station transformers as an example. When one station transformer needs to be out of service, there are two operation methods: non-interruptive power supply and instantaneous power interruption. Generally, the method of instantaneous power interruption on the low-voltage side is preferred.The operation method for instantaneous power interruption on the low-voltage side is as follows:Open the 380V power incoming circuit breaker of the corresponding sec
Vziman
07/26/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!