Basic info
Brand RW Energy
Model NO. BI-DIRECTIONAL DC Fast Charger
Rated Output Rating 40KW
Output Voltage DC 200-1000V
Power Conversion Efficiency ≥95%
Connector Options CCS1
Cable Length 5m
Input Voltage 380V
Series DC EV Chargers
Product Detail

BI-DIRECTIONAL DC Fast Charger

This BI-DIRECTIONAL DC Fast Charger supports three major modes: V2G (Vehicle-to-Grid), V2L (Vehicle-to-Load), and V2H (Vehicle-to-Home), redefining electrical energy interaction. With V2G technology, vehicles can charge during low-power consumption periods and feed power back to the grid during peak hours, aiding in peak shaving and valley filling while generating revenue. In V2L mode, the charger transforms into a high-power mobile power source, providing stable electricity for camping equipment, outdoor machinery, emergency rescue gear, and other loads. The V2H function enables electric vehicles to serve as home backup power, ensuring household appliances operate during power outages or optimizing home electricity costs. Supporting a maximum charging power of 350kW and discharging power of 100kW, it is equipped with an intelligent power regulation and bidirectional energy management system to ensure efficient, stable, and safe bidirectional power transmission, making it a core device for the future smart energy ecosystem.

Features:

  •  Connectors - GBT/CCS1/CCS2/CHAdeMO/Tesla.

  • Support V2G/V2L/V2H.

  • Configurable output power settings.

  • RFID Reader.

  • Optional Credit Card Reader.

  •  Station-level monitoring platform.

  • FRU Onboard Diagnostics.

  •  Easy to Service.

Specifications:

image.png

image.png

image.png

image.png

Bi-directional function:

  • V2G (Vehicle to Grid): Vehicle to grid. That is, electric vehicles can not only obtain electrical energy from the grid for charging, but also feed back the electrical energy in the vehicle battery to the grid under certain circumstances to realize reverse transmission of electrical energy. This helps to peak-shave and valley-fill the grid, improve the stability and efficiency of the grid. At the same time, vehicle owners may also obtain certain economic benefits.

  • V2L (Vehicle to Load): Vehicle to load. It can use electric vehicles as a mobile power source to supply power to other external load devices. For example, when camping outdoors, it can supply power to electric ovens, stereos and other devices, expanding the usage scenarios of electric vehicles.

  • V2H (Vehicle to Home): Vehicle to home. It enables electric vehicles to be connected to the home's power system and provide emergency power for the home in case of power outages or charge at low electricity prices and supply power to the home at peak times to save home electricity costs.

what is V2G technology? In short, it is based on two-way charging piles, combined with energy management systems and cloud platform intelligent scheduling technology, and connected to the power grid dispatching system to realize the intelligent two-way transmission of electrical energy between the power grid and vehicles, meeting the purposes of vehicle transportation, new energy access, and stable control of the power grid.

Know your supplier
RW Energy
Zhejiang Rockwell Energy Technology Co., Ltd. is an international enterprise specializing in the research, development and manufacturing of recloser controllers, power quality management, power monitoring systems and other high-end power equipment. In today's critical period of global energy transition and power system upgrading, the company has gathered a group of top talents in the fields of power engineering, automation control, software development, etc., who carry the enthusiasm and persistence for the power business, and are committed to overcoming the complex problems in the power system, and promoting the intelligent development of the power industry with innovative technology. Mission: To make global electricity smarter, more reliable and more efficient with innovative technology. Vision: To be the leader in global power intelligence.
Main Categories
High Voltage Electrical Apparatus/New energy/Tester
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$100000000
Professional Experience
12 years
Workplace
30000m²
占位
占位
Related Products
Related Knowledges
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
For users, when purchasing a 35kV new energy transformer, choosing between dry-type, mineral oil-filled, or vegetable oil-filled types involves multiple considerations. These include user habits, maintenance-free performance, safety and fire resistance, volume and weight, among others. However, cost differences are undoubtedly one of the most crucial factors.To illustrate the issue intuitively, this paper selects a three-level energy efficiency dual-winding new energy transformer with a rated ca
Ron
07/26/2025
What is the connection group of a transformer?
What is the connection group of a transformer?
Transformer Connection GroupThe connection group of a transformer refers to the phase difference between the primary and secondary voltages or currents. It is determined by the winding directions of the primary and secondary coils, the labeling of their start and end terminals, and the connection mode. Expressed in a clock-like format, there are 12 groups in total, numbered from 0 to 11.The DC method is commonly used to measure the transformer's connection group, mainly to verify whether the con
Vziman
07/26/2025
Working Voltage in Power System
Working Voltage in Power System
Working VoltageThe term "working voltage" refers to the maximum voltage that a device can withstand without sustaining damage or burning out, while ensuring the reliability, safety, and proper operation of both the device and associated circuits.For long-distance power transmission, the use of high voltage is advantageous. In AC systems, maintaining a load power factor as close to unity as possible is also economically necessary. Practically, heavy currents are more challenging to handle than hi
Encyclopedia
07/26/2025
What is Steady State Stability in Power System?
What is Steady State Stability in Power System?
Definition of Steady State StabilitySteady state stability is defined as the capability of an electric power system to sustain its initial operating condition following a small disturbance, or to converge to a state closely approximating the initial condition when the disturbance persists. This concept holds critical significance in power system planning and design, the development of specialized automatic control devices, the commissioning of new system components, and the adjustment of operati
Edwiin
07/26/2025
What is the sequence for powering down the transformer?
What is the sequence for powering down the transformer?
The sequence for shutting down a main transformer is as follows: when de-energizing, the load side should be shut down first, followed by the power supply side. For energizing operations, the reverse order applies: the power supply side is energized first, then the load side. This is because: Energizing from the power supply side to the load side makes it easier to identify the fault range and take prompt judgment and handling measures in case of a fault, preventing the fault from spreading or e
Rockwell
07/26/2025
What are the methods for switching operations of station transformers?
What are the methods for switching operations of station transformers?
Let's take an auxiliary power system with two station transformers as an example. When one station transformer needs to be out of service, there are two operation methods: non-interruptive power supply and instantaneous power interruption. Generally, the method of instantaneous power interruption on the low-voltage side is preferred.The operation method for instantaneous power interruption on the low-voltage side is as follows:Open the 380V power incoming circuit breaker of the corresponding sec