• Power-Zone™ 4 Low Voltage Switchgear with MasterPacT™ MTZ or NW/NT Circuit Breakers
Power-Zone™ 4 Low Voltage Switchgear with MasterPacT™ MTZ or NW/NT Circuit Breakers
discuss personally
Model
Power-Zone™ 4 -1600A
Basic info
Brand Schneider
Model NO. Power-Zone™ 4 Low Voltage Switchgear with MasterPacT™ MTZ or NW/NT Circuit Breakers
Rated normal current 1600A
Series Power-Zone™ 4
Product Detail

General

Square D™ brand Power-Zone™ 4 low voltage, metal-enclosed, drawout switchgear is designed to provide superior electrical distribution, protection, and power quality management. The prime components of the switchgear are the MasterPacT™ ANSI rated circuit breaker. Power-Zone 4 switchgear is designed to maximize the functionality of the MasterPacT circuit breakers, which, in turn, deliver maximum uptime, system selectivity, ease of maintenance, and reliable circuit protection. All of these features are packed into the smallest footprint available for low voltage drawout switchgear.

Features

  • Power-Zone 4 is designed and built to ANSI® C37.20.1 and is Listed to UL 1558  
  • MasterPacT MTZ, NW and NT drawout low voltage power circuit breakers are designed and built to ANSI C37.13 and C37.16. Listed to UL 1066  
  • Short-circuit current rating up to 200 kA at 240 V and 480 V without fuses
  • High short-time withstand ratings up to 100 kA for 1 second, minimum  
  • Arc flash limiting (L1F) MasterPacT MTZ2 or NW feeder breakers available in 800, 1600, and 2000 A ratings  
  • Family of field installable and upgradeable MicroLogic™ trip units with optional EcoStruxure Power™ data communications features
  • Power-Zone 4 switchgear can offer optional factory integrated data communications capability with Ethernet (Modbus TCP/IP) connectivity to EcoStruxure Power Edge Control or Asset Management software  
  • Smallest equipment footprint available in this product class  
  • Front access to all control and communications wire connections  
  • Bolted copper bus provided as standard (up to 6000 A maximum)
  • Large rear cable compartment pull area allowing maximum room for power cables  
  • Horizontal bus provision for future equipment expansion  
  • System designed for maximum uptime with low maintenance  
  • Modular circuit breaker designed for easy addition of control accessories  
  • Available in NEMA 3R outdoor walk-in enclosures  
  • Available in 42" deep, front accessible only version for greater layout flexibility and optimized electrical house footprint

Equipment Ratings

Know your supplier
Schneider
Chengdu Fabo Automation Complete Equipment Co., Ltd is an authorized distributor of Schneider Electric, a global leader in energy management and automation solutions.
Main Categories
High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus
Business Type
Manufacture/Sales
Highest Annual Export (USD)
$400000000
Professional Experience
10 years
Workplace
20000m²
占位
占位
Related Products
Related Knowledges
How is the contradiction between the small grounding residual current and the neutral point displacement voltage exceeding the standard resolved?
How is the contradiction between the small grounding residual current and the neutral point displacement voltage exceeding the standard resolved?
Contradiction PointsIn automatic tracking arc suppression coils, the adjustment precision is high, the residual current is small, and the operation is close to the resonance point.In an automatic tracking arc suppression coil grounding system, two factors must be considered: Under normal operating conditions, the long-term voltage displacement of the neutral point should not exceed 15% of the system's nominal phase voltage; In the case of a ground fault, the grounding residual current should be
Edwiin
07/28/2025
Power Supply Design of the Group Testing Device for Special Transformers in Electrified Railways
Power Supply Design of the Group Testing Device for Special Transformers in Electrified Railways
1 Hardware Design of Tester Power SupplyThis device uses a standard small - signal generating device to generate small - current signals with the required frequency and phase angle. Then, through the amplifying circuit and phase - modulating circuit, the working power supply is generated.1.1 Power Frequency Sine Wave Small - Current Signal Generating DeviceThe sine wave generating circuit is mainly composed of the waveform generating chip MAX038 produced by MAXIM Corporation of the United States
Ron
07/28/2025
Analysis of Testing Methods for Turns Ratio and Connection Mode of Special Transformers
Analysis of Testing Methods for Turns Ratio and Connection Mode of Special Transformers
1 Error Analysis of Traditional Turn Ratio Testing MethodsThe QJ35 turn ratio bridge and other single-phase-phase-based testers all use the double-voltmeter principle. The QJ35, however, eliminates power supply fluctuation interference via bridge balance. For three-phase transformer ratio testing with a single power supply, corresponding terminals must be shorted and data converted, turning three-phase tests into independent single-phase measurements, with √3 Yd conversion based on connect
Felix Spark
07/28/2025
What are the production processes of special transformers?
What are the production processes of special transformers?
A certain special transformer manufacturing enterprise, which has been producing special transformers such as split - phase - shifting rectifier transformers, rectifier transformers for electrolysis, and transformers for submerged arc furnaces for more than 20 years. Now, an evaluation is made on the production process flow and its characteristics of the special transformers after the company's transformation.1.Production Process Flow Chart of Special TransformersThe production of special transf
Leon
07/28/2025
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
For users, when purchasing a 35kV new energy transformer, choosing between dry-type, mineral oil-filled, or vegetable oil-filled types involves multiple considerations. These include user habits, maintenance-free performance, safety and fire resistance, volume and weight, among others. However, cost differences are undoubtedly one of the most crucial factors.To illustrate the issue intuitively, this paper selects a three-level energy efficiency dual-winding new energy transformer with a rated ca
Ron
07/26/2025
What is the connection group of a transformer?
What is the connection group of a transformer?
Transformer Connection GroupThe connection group of a transformer refers to the phase difference between the primary and secondary voltages or currents. It is determined by the winding directions of the primary and secondary coils, the labeling of their start and end terminals, and the connection mode. Expressed in a clock-like format, there are 12 groups in total, numbered from 0 to 11.The DC method is commonly used to measure the transformer's connection group, mainly to verify whether the con
Vziman
07/26/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!