Model
LZW-72.5
Basic info
Brand Wone Store
Model NO. LZW-72.5 Outdoor Current Transformer
Rated voltage 66kV
Rated frequency 50/60Hz
Rated current ratio 500/5
Series LZW
Product Detail

Product Overview

LZW-72.5 current transformer, epoxy resin casting insulation and outdoor installation, is widely used for measuring current, electric energy and protective relaying in the power system with the rated frequency 50Hz or 60 Hz and rated voltage 66kV or 69kV.

Key Features

  • High-Voltage Grade Outdoor-Specific Design:The LZW-72.5 features a 72.5kV rated voltage design with insulation levels reaching 125kV (lightning impulse) / 70kV (power frequency withstand voltage). It strictly complies with GB/T 4703.2 and IEC 60044-2 standards, optimized for high-voltage outdoor scenarios such as 110kV and below outdoor substations and overhead lines. This ensures safe and stable operation in long-term high-voltage environments, effectively reducing the risk of insulation breakdown.

  •  Extreme Climate Protection Structure:The product incorporates a triple protection system: it uses silicone rubber composite insulation materials and aluminum alloy flanges, achieving 10,000 hours of UV aging resistance; reaches IP68+ protection, enabling long-term operation at 2 meters underwater, with special designs to withstand 30mm/h snow accumulation and ice loads up to 20mm thickness; passes 3,000 hours of salt spray testing, with a creepage distance of 31mm/kV, fully meeting the requirements of harsh outdoor environments such as plateaus, extreme cold, and coastal areas.

  • Dual-Winding High-Precision Measurement System:The LZW-72.5 integrates a 0.2S-class metering winding and a 5P30-class protection winding. The metering winding maintains a ratio error ≤±0.2% within 1%~120% rated current, meeting high-precision energy metering needs; the protection winding has a composite error ≤5% at 30 times rated current with 8ms fast response, effectively ensuring the speed of relay protection devices. It includes 3 sets of ratio taps (e.g., 600/5A, 800/5A, 1000/5A), which can be flexibly adjusted via an outdoor-specific sealed switch without disassembly to adapt to different load current scenarios.

  • Intelligent Condition Monitoring and Communication Technology:The product is equipped with multi-parameter sensors for temperature (-40℃~+120℃), humidity, and insulation dielectric loss, collecting real-time operational data. It supports IEC 61850-9-2 digital protocol and DL/T 645 standard, while retaining a 4~20mA analog output interface, enabling seamless integration into smart substation systems or compatibility with old monitoring equipment. In-depth analysis of historical data through cloud platforms predicts insulation aging trends in advance, providing data support for operation and maintenance decisions and significantly reducing outdoor inspection frequency and costs.

Main technical parameter

  • Rated voltage : 66kV or 69kV

  • Highest voltage for equipment : 72.5 kV

  • Rated insulation level : 72.5/140/325kV

  • Rated secondary current :5Aor1A

  • Standards: IEC60044-1.2003 Part 1: Instrument transformers-Part1: Current transformers or ANSI IEEE STD C57.13-2008

Other technical parameter pls see as follow:

Double ratios

Remarks: Upon request we are glad to offer transformers according to other standards or with non-standard technical specs.

Outline drawing

 

 

 

Know your supplier
Wone Store
Main Categories
High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment/Instrument Transformer/Equipment Parts
Business Type
Sales
Highest Annual Export (USD)
$300000000
Professional Experience
1 years
Workplace
1000m²
占位
占位
Related Products
Related Knowledges
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
For users, when purchasing a 35kV new energy transformer, choosing between dry-type, mineral oil-filled, or vegetable oil-filled types involves multiple considerations. These include user habits, maintenance-free performance, safety and fire resistance, volume and weight, among others. However, cost differences are undoubtedly one of the most crucial factors.To illustrate the issue intuitively, this paper selects a three-level energy efficiency dual-winding new energy transformer with a rated ca
Ron
07/26/2025
What is the connection group of a transformer?
What is the connection group of a transformer?
Transformer Connection GroupThe connection group of a transformer refers to the phase difference between the primary and secondary voltages or currents. It is determined by the winding directions of the primary and secondary coils, the labeling of their start and end terminals, and the connection mode. Expressed in a clock-like format, there are 12 groups in total, numbered from 0 to 11.The DC method is commonly used to measure the transformer's connection group, mainly to verify whether the con
Vziman
07/26/2025
Working Voltage in Power System
Working Voltage in Power System
Working VoltageThe term "working voltage" refers to the maximum voltage that a device can withstand without sustaining damage or burning out, while ensuring the reliability, safety, and proper operation of both the device and associated circuits.For long-distance power transmission, the use of high voltage is advantageous. In AC systems, maintaining a load power factor as close to unity as possible is also economically necessary. Practically, heavy currents are more challenging to handle than hi
Encyclopedia
07/26/2025
What is Steady State Stability in Power System?
What is Steady State Stability in Power System?
Definition of Steady State StabilitySteady state stability is defined as the capability of an electric power system to sustain its initial operating condition following a small disturbance, or to converge to a state closely approximating the initial condition when the disturbance persists. This concept holds critical significance in power system planning and design, the development of specialized automatic control devices, the commissioning of new system components, and the adjustment of operati
Edwiin
07/26/2025
What is the sequence for powering down the transformer?
What is the sequence for powering down the transformer?
The sequence for shutting down a main transformer is as follows: when de-energizing, the load side should be shut down first, followed by the power supply side. For energizing operations, the reverse order applies: the power supply side is energized first, then the load side. This is because: Energizing from the power supply side to the load side makes it easier to identify the fault range and take prompt judgment and handling measures in case of a fault, preventing the fault from spreading or e
Rockwell
07/26/2025
What are the methods for switching operations of station transformers?
What are the methods for switching operations of station transformers?
Let's take an auxiliary power system with two station transformers as an example. When one station transformer needs to be out of service, there are two operation methods: non-interruptive power supply and instantaneous power interruption. Generally, the method of instantaneous power interruption on the low-voltage side is preferred.The operation method for instantaneous power interruption on the low-voltage side is as follows:Open the 380V power incoming circuit breaker of the corresponding sec
Vziman
07/26/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!