• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


Free Expert Guides on Power Systems, Circuit Design & Electrical Troubleshooting

Access free engineering resources from IEE Business—covering power design, circuit layout, equipment selection, and troubleshooting. Expert-developed guides help engineers, procurement, and project teams make better decisions. Stay ahead on smart grids, renewables, efficiency, and AI tools. Improve reliability, reduce downtime, and enhance outcomes with real-world solutions. Explore our knowledge hub today.
Research on Detection and Gas Filling and Replenishment Devices for Non-disassembly SF6 Circuit Breakers
High - voltage circuit breakers are used to connect or cut off load currents during normal operation. When a short - circuit fault or severe over - load occurs in electrical equipment or lines, a relay protection device controls them to automatically and quickly cut off the fault current, isolating the equipment or lines with the short - circuit fault to prevent the expansion of the accident scope.Throughout the development of high - voltage circuit breakers, from oil - filled circuit breakers a
05/09/2025
Consult
Tip
Consult
Tip
Analysis and Improvement of the Burnout of the closing coil caused by the energy storage fault of the High-voltage SF6 circuit breaker
High - voltage SF₆ circuit breakers are three - phase AC 50Hz outdoor high - voltage electrical equipment. They adopt a self - energy arc - extinguishing chamber structure and are equipped with spring operating mechanisms. These circuit breakers feature a simple structure, convenient operation, and high safety and reliability. Therefore, they are widely used for the control and protection of transmission and distribution lines and can also serve as tie - type circuit breakers.The 110kV system of
05/09/2025
Consult
Tip
Consult
Tip
Analysis of the Causes of Insulation breakdown faults in SF6 Circuit Breakers in the open State
The GIS (Gas Insulated Switchgear) utilizes SF₆ gas as both the insulating and arc-extinguishing medium. It boasts several advantages, such as a small footprint, high reliability, excellent safety, and convenient maintenance. The SF₆ circuit breaker, being an integral part of the GIS equipment, holds a dominant position in voltage levels of 110 kV and above.This article details a fault that occurred during the power generation and synchronization process of Unit 1 in a certain power plant. Speci
05/09/2025
Consult
Tip
Consult
Tip
Research on Fault Analysis and Handling Methods of SF6 Circuit Breakers
In the substation system, high - voltage circuit breakers are power - interrupting devices, among which SF₆ circuit breakers are the most common. Such circuit breakers use SF₆ gas as the main insulating medium. Based on the action of arc energy, SF₆ compressed gas is formed to instantly extinguish the arc, thus achieving the interruption of rated current and fault current, protecting power - cutting lines and electrical equipment from damage. The system is equipped with a complete operating syst
05/08/2025
Consult
Tip
Consult
Tip
A Brief Discussion on the Testing and Analysis of Gas Micro-Water in SF6 Circuit Breakers
SF₆ circuit breakers possess excellent physical, chemical, insulation, and arc - extinguishing properties. They allow for a large number of consecutive interruptions, have low noise, and pose no risk of sparking. Additionally, they are small in size, light in weight, large in capacity, and require little or no maintenance. As a result, they are gradually replacing traditional oil - filled circuit breakers and compressed - air circuit breakers. Moreover, in medium - voltage power distribution, th
05/08/2025
Consult
Tip
Consult
Tip
The method of testing the loop resistance of 110kV and 220kVSF6 circuit breakers using loop resistance test rods
Circuit breakers are among the most crucial electrical devices in the power system. They are electrical devices capable of interrupting, closing, and carrying the normal current of an operating line, and can carry, close, and interrupt specified abnormal currents (such as short - circuit currents) within a specified time. Good contact in the conductive circuit of a circuit breaker is a vital condition for ensuring its safe operation. If the contact is poor, it can cause the switch to overheat or
05/08/2025
Consult
Tip
Consult
Tip
A Brief Analysis of Key Points for the Operation and Maintenance of High-Voltage SF6 Circuit Breakers
1 OverviewCircuit breakers can connect and disconnect circuits according to the operating mode under normal conditions. They can also quickly cut off faulty equipment based on secondary protection signals when a fault occurs, or connect the circuit to restore power supply after a transient fault is eliminated. Thus, they have the dual functions of control and protection . Currently, there are more than a hundred substations in the Pingdingshan area. In each substation, circuit breakers are requi
05/08/2025
Consult
Tip
Consult
Tip
Research on Hazard Points and Safety Control Technologies at Substation Maintenance Sites Based on High-voltage SF₆ Circuit Breakers
With the rapid development of the power industry and the continuous expansion of the power grid, high-voltage electrical equipment has become increasingly important in the power system. As a key device in the power system, high-voltage SF₆ circuit breakers play a crucial role in cutting off and closing circuits, as well as quickly interrupting fault currents during system failures. Thanks to their high reliability, excellent insulation performance, and arc-extinguishing capabilities, SF₆ circuit
05/08/2025
Consult
Tip
Consult
Tip
Design and Implementation of a Gas Heating Device for 110kV Porcelain Column SF6 Circuit Breaker
High - voltage circuit breakers are one of the most crucial control appliances in the power system. The operation status of high - voltage circuit breakers directly affects the safe and stable operation of the power system. Among them, the outdoor porcelain post type SF₆ circuit breaker is one of the main types of high - voltage circuit breaker. SF₆ has a high electrical withstand strength, excellent arc - extinguishing performance, and insulation capability. However, in practical applications,
05/08/2025
Consult
Tip
Consult
Tip
Analysis of Common Faults of High-Voltage SF6 Circuit Breakers in Substation Maintenance
1 Basic Structure and Working Principle of High - voltage SF₆ Circuit BreakersHigh - voltage SF₆ circuit breakers, as indispensable key equipment in the power system, their structure and working principle are the cornerstones ensuring the safe and stable operation of the power grid. It is composed of multiple precision components, including but not limited to insulators, conductive parts, arc - extinguishing chambers, operating mechanisms, and control circuits. Insulators usually adopt high - st
05/08/2025
Consult
Tip
Consult
Tip
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.