• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


Free Expert Guides on Power Systems, Circuit Design & Electrical Troubleshooting

Access free engineering resources from IEE Business—covering power design, circuit layout, equipment selection, and troubleshooting. Expert-developed guides help engineers, procurement, and project teams make better decisions. Stay ahead on smart grids, renewables, efficiency, and AI tools. Improve reliability, reduce downtime, and enhance outcomes with real-world solutions. Explore our knowledge hub today.
Analysis of the Fault Causes and Handling Steps of SF6 Circuit Breakers
In an SF₆ circuit breaker, the SF₆ gas can decompose into toxic and corrosive gases and water in a high-temperature environment, which can damage the insulating layer. To prevent this situation, while effectively strengthening the protection of electrical components, the insulation level should also be improved. In addition, faults should be analyzed, and corresponding measures should be taken for treatment.1 Case AnalysisA 110 kV switch in a substation was struck by lightning, causing a reclosi
05/09/2025
Consult
Tip
Consult
Tip
Analysis of Common Causes of Gas Leakage in SF6 Circuit Breakers of Substations and Research on Detection Measures
With the advancement of technology and the improvement of production levels, the performance and quality of SF₆ circuit breaker equipment have been continuously enhanced, and the products have been widely recognized by customers. However, with its extensive application, the frequency of faults has also increased. The causes of faults include issues such as design principles, manufacturing processes, and material selection. Through investigation and statistics on the causes of faults, it is known
05/09/2025
Consult
Tip
Consult
Tip
The current situation and development trend of high-voltage SF6 circuit breakers
High-voltage circuit breakers, also known as high-voltage switches, possess sufficient interrupting and arc-extinguishing capabilities. They can not only cut off and close the no-load current and load current of high-voltage circuits but also, when a fault occurs in the system, cooperate with protection devices and automatic devices to quickly cut off the fault current, reducing the power outage range and preventing the expansion of the accident. This is of great significance for ensuring the sa
05/09/2025
Consult
Tip
Consult
Tip
Research on Detection and Gas Filling and Replenishment Devices for Non-disassembly SF6 Circuit Breakers
High - voltage circuit breakers are used to connect or cut off load currents during normal operation. When a short - circuit fault or severe over - load occurs in electrical equipment or lines, a relay protection device controls them to automatically and quickly cut off the fault current, isolating the equipment or lines with the short - circuit fault to prevent the expansion of the accident scope.Throughout the development of high - voltage circuit breakers, from oil - filled circuit breakers a
05/09/2025
Consult
Tip
Consult
Tip
Analysis and Improvement of the Burnout of the closing coil caused by the energy storage fault of the High-voltage SF6 circuit breaker
High - voltage SF₆ circuit breakers are three - phase AC 50Hz outdoor high - voltage electrical equipment. They adopt a self - energy arc - extinguishing chamber structure and are equipped with spring operating mechanisms. These circuit breakers feature a simple structure, convenient operation, and high safety and reliability. Therefore, they are widely used for the control and protection of transmission and distribution lines and can also serve as tie - type circuit breakers.The 110kV system of
05/09/2025
Consult
Tip
Consult
Tip
Analysis of the Causes of Insulation breakdown faults in SF6 Circuit Breakers in the open State
The GIS (Gas Insulated Switchgear) utilizes SF₆ gas as both the insulating and arc-extinguishing medium. It boasts several advantages, such as a small footprint, high reliability, excellent safety, and convenient maintenance. The SF₆ circuit breaker, being an integral part of the GIS equipment, holds a dominant position in voltage levels of 110 kV and above.This article details a fault that occurred during the power generation and synchronization process of Unit 1 in a certain power plant. Speci
05/09/2025
Consult
Tip
Consult
Tip
Research on Fault Analysis and Handling Methods of SF6 Circuit Breakers
In the substation system, high - voltage circuit breakers are power - interrupting devices, among which SF₆ circuit breakers are the most common. Such circuit breakers use SF₆ gas as the main insulating medium. Based on the action of arc energy, SF₆ compressed gas is formed to instantly extinguish the arc, thus achieving the interruption of rated current and fault current, protecting power - cutting lines and electrical equipment from damage. The system is equipped with a complete operating syst
05/08/2025
Consult
Tip
Consult
Tip
A Brief Discussion on the Testing and Analysis of Gas Micro-Water in SF6 Circuit Breakers
SF₆ circuit breakers possess excellent physical, chemical, insulation, and arc - extinguishing properties. They allow for a large number of consecutive interruptions, have low noise, and pose no risk of sparking. Additionally, they are small in size, light in weight, large in capacity, and require little or no maintenance. As a result, they are gradually replacing traditional oil - filled circuit breakers and compressed - air circuit breakers. Moreover, in medium - voltage power distribution, th
05/08/2025
Consult
Tip
Consult
Tip
The method of testing the loop resistance of 110kV and 220kVSF6 circuit breakers using loop resistance test rods
Circuit breakers are among the most crucial electrical devices in the power system. They are electrical devices capable of interrupting, closing, and carrying the normal current of an operating line, and can carry, close, and interrupt specified abnormal currents (such as short - circuit currents) within a specified time. Good contact in the conductive circuit of a circuit breaker is a vital condition for ensuring its safe operation. If the contact is poor, it can cause the switch to overheat or
05/08/2025
Consult
Tip
Consult
Tip
A Brief Analysis of Key Points for the Operation and Maintenance of High-Voltage SF6 Circuit Breakers
1 OverviewCircuit breakers can connect and disconnect circuits according to the operating mode under normal conditions. They can also quickly cut off faulty equipment based on secondary protection signals when a fault occurs, or connect the circuit to restore power supply after a transient fault is eliminated. Thus, they have the dual functions of control and protection . Currently, there are more than a hundred substations in the Pingdingshan area. In each substation, circuit breakers are requi
05/08/2025
Consult
Tip
Consult
Tip
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.