Access free engineering resources from IEE Business—covering power design, circuit layout, equipment selection, and troubleshooting. Expert-developed guides help engineers, procurement, and project teams make better decisions. Stay ahead on smart grids, renewables, efficiency, and AI tools. Improve reliability, reduce downtime, and enhance outcomes with real-world solutions. Explore our knowledge hub today.
Low frequency AC short circuit generators fault test for HVDC circuit breakers
Given the Circuit Breaker Operating Time, the Magnitude of the Driving Voltage, the Turn-On Angle, the Circuit Inductance, and the Generator Frequency Are Key Design Parameters for Achieving Sufficient di/dt and Adequate Energy Supply.After current interruption, the dielectric stress can be provided by a separate DC voltage source, although this presents some practical challenges. The capacitor remains charged throughout the energy absorption period, with its value equal to the TRV (Transient Re
11/20/2024
Consult
Tip
Consult
Tip
HVDC main challenges with protection and switching
DC Fault Current Has No Natural Zero CrossingDC fault current does not have a natural zero crossing. This presents a problem because all mechanical DC circuit breakers rely on the natural zero crossing to interrupt the current arc.Reduced Impedance in DC LinesThe impedance in DC lines is significantly lower. This means that the magnitude of fault currents during DC faults is much higher, and the voltage levels across the entire grid are lower.Difficulty in Locating FaultsDue to the low impedance
11/19/2024
Consult
Tip
Consult
Tip
Artificial current zero crossing creating method for DC switchgear
This method involves injecting or superimposing a current in the opposite direction of the current to be interrupted. The superimposed current can be provided through interaction with a parallel resonant circuit or by actively injecting current, thereby creating an artificial current zero crossing. Once the artificial current zero crossing is achieved, the interruption process is similar to that in an AC circuit.Working PrincipleThe diagram below illustrates the scheme of actively injecting a cu
11/18/2024
Consult
Tip
Consult
Tip
Filter Earthing Switch(FES) role in HVDC grids
High voltage ground switch definitionA high-voltage ground switch is a mechanical switching device used to connect high-voltage electrical equipment or lines to the ground to ensure safety during equipment overhaul or troubleshooting. It is usually installed next to high-voltage circuit breakers, isolation switches, transformers and other devices to ground high-voltage circuits quickly and reliably when needed.The role of the filter grounding switch in the HVDC network:The main function of the f
11/15/2024
Consult
Tip
Consult
Tip
Hybrid HVDC Breaker Definitions
Definitions for Hybrid HVDC Circuit BreakersStandard Definitions for AC Circuit Breakers Limitations: The standard definitions for AC circuit breakers do not directly translate to HVDC protection because the time frames and dynamics involved are different. Time Frames: AC circuit breakers have a relatively long time to act compared to DC circuit breakers. Typically, the fault currents that an AC circuit breaker interrupts will have nearly reached steady state by the time the protection acts, but
11/14/2024
Consult
Tip
Consult
Tip
Medium Voltage DC Solid-State Circuit Breakers Design and future
How medium voltage solid-state circuit breaker work:A solid-state DC breaker uses power semiconductors to interrupt the fault current. A simple topology of a solid-state DC breaker is shown in Figure. 1. Four diodes and an IGCT represent the main conduction path, while the surge arrester is used to discharge the line inductance in case of a fault. When the DC breaker is tripped, the IGCT is turned off. Due to the inductively stored energy, the voltage across the semiconductors rises quickly and
11/13/2024
Consult
Tip
Consult
Tip
What is a double pole switch, and where is it used?
A double-pole switch is a type of switch that can control two separate circuits simultaneously. Unlike a single-pole switch, which controls only one circuit, a double-pole switch can open or close two independent circuits at the same time. This type of switch is very useful in various applications, especially when it is necessary to control two related or independent circuits simultaneously.Basic Concepts of Double-Pole Switches1. DefinitionA double-pole switch has two independent contacts, each
11/12/2024
Consult
Tip
Consult
Tip
Disconnector Switches Grouping in HVDC Grids
HVDC disconnector switches:HVDC disconnecting switches (DS) are used to disconnect various circuits in HVDC transmission networks. For example, the HVDC DS is applied to switching duties such as line or cable-charging current switching, no-load line, or cable transfer switching, in addition to disconnecting equipment including a converter bank (thyristor valve), a filter bank, and a grounding line. HVDC DS is also applied to DC switchgear to terminate the residual or leakage current through an in
11/12/2024
Consult
Tip
Consult
Tip
Medium Voltage DC Circuit Breaker Types and Applications
Medium voltage DC circuit breakers are suitable for applications in ships, urban subways, electric trains, microgrids (electric vehicles), distributed generation (solar energy), and battery-based systems (data centers).The relatively low circuit impedance in a DC case leads to higher amplitudes of short circuits. Furthermore, because transformer windings do not contribute to the overall time constant in DC systems, the overall time constant shrinks and a short circuit can have rise times as brie
11/11/2024
Consult
Tip
Consult
Tip
What are the potential drawbacks of using mini-circuit breakers instead of fuses for power distribution?
Using miniature circuit breakers (MCBs) instead of fuses for electrical distribution has many advantages, but it also comes with some potential disadvantages. Here are the main potential drawbacks:1. CostInitial Cost: The initial cost of MCBs is typically higher than that of fuses. MCBs contain more mechanical and electronic components, making them more expensive to manufacture.Maintenance Cost: While MCBs have a longer lifespan and can be reused, they may require repair or replacement if they f
11/09/2024