Free Expert Guides on Power Systems, Circuit Design & Electrical Troubleshooting

Access free engineering resources from IEE Business—covering power design, circuit layout, equipment selection, and troubleshooting. Expert-developed guides help engineers, procurement, and project teams make better decisions. Stay ahead on smart grids, renewables, efficiency, and AI tools. Improve reliability, reduce downtime, and enhance outcomes with real-world solutions. Explore our knowledge hub today.
Analysis and Treatment of Fault Causes of 35 kV Outdoor Vacuum Circuit Breaker
Fault PhenomenonOn June 23, 2020, a fault occurred in the 35 kV feeder bay that was on hot standby at a 220 kV substation. This triggered the operation of the first - stage, first - time - limit voltage - restrained overcurrent protection of the low - voltage backup protection of the No. 2 main transformer and the second - stage overcurrent protection of the 350 bus tie protection. Consequently, the 352 circuit breaker on the low - voltage side corresponding to the No. 2 main transformer and the
04/18/2025
Consult
Tip
Consult
Tip
Surface Discharge Detection of External Insulation of Outdoor Vacuum Circuit Breaker Based on Ultraviolet Imaging
Outdoor vacuum circuit breakers (referred to as breakers hereinafter) are widely used in the distribution network due to their advantages such as small size, light weight, fire - and explosion - proof nature, smooth operation, low noise, small open - contact clearance, short arcing time, and easy maintenance. As atmospheric pollution becomes increasingly severe, in adverse weather conditions like heavy fog, drizzle, condensation, or ice melting, partial discharge (PD) is likely to occur on the s
04/18/2025
Consult
Tip
Consult
Tip
Behaviour of Outdoor Vacuum Circuit breakers Under Simulated Environments
Outdoor vacuum circuit breakers are predominantly utilized in the Medium High Voltage (MHV) segment. They serve as a crucial component in the distribution sector, especially within 11kV and 33kV grids. A variety of composite materials are employed in the construction of these breakers. Among them, the vacuum interrupter stands out as the most vital component. For outdoor circuit breakers, the vacuum interrupter is typically encased in a porcelain housing.These breakers are connected to the opera
04/17/2025
Consult
Tip
Consult
Tip
Intelligent outdoor vacuum circuit breaker
IntelligenceIntelligent Monitoring and Diagnosis Multi - parameter Real - time Monitoring: Outdoor vacuum circuit breakers will be extensively integrated with various high - precision sensors, which are like the "sensory nerves" of the circuit breaker. For example, displacement sensors are used to accurately measure the contact travel, keeping track of the position changes of the contacts during the opening and closing processes in real - time; speed sensors are utilized to monitor the opening a
04/17/2025
Consult
Tip
Consult
Tip
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application