Free Expert Guides on Power Systems, Circuit Design & Electrical Troubleshooting

Access free engineering resources from IEE Business—covering power design, circuit layout, equipment selection, and troubleshooting. Expert-developed guides help engineers, procurement, and project teams make better decisions. Stay ahead on smart grids, renewables, efficiency, and AI tools. Improve reliability, reduce downtime, and enhance outcomes with real-world solutions. Explore our knowledge hub today.
Intelligent outdoor vacuum circuit breaker
IntelligenceIntelligent Monitoring and Diagnosis Multi - parameter Real - time Monitoring: Outdoor vacuum circuit breakers will be extensively integrated with various high - precision sensors, which are like the "sensory nerves" of the circuit breaker. For example, displacement sensors are used to accurately measure the contact travel, keeping track of the position changes of the contacts during the opening and closing processes in real - time; speed sensors are utilized to monitor the opening a
04/17/2025
Consult
Tip
Consult
Tip
 What is Overcurrent Relay?
What is Overcurrent Relay?DefinitionAn overcurrent relay is defined as a relay that activates only when the current value exceeds the relay's set value. It safeguards the equipment in the power system from fault currents.Classification Based on Operation TimeBased on the time it takes to operate, the overcurrent relay can be categorized into the following types: Instantaneous Overcurrent Relay Inverse Time Overcurrent Relay Definite Time Overcurrent Relay Inverse Definite Time Overcurrent Relay
04/16/2025
Consult
Tip
Consult
Tip
What is Static Relay ?
What is Static Relay ?Definition: A relay that has no moving parts is referred to as a static relay. In this type of relay, the output is generated by static components such as magnetic and electronic circuits. Even if a relay combines static elements with an electromagnetic relay, it is still called a static relay. This is because the static units are responsible for sensing the input and generating a response, while the electromagnetic relay is merely utilized for the switching operation.The c
04/15/2025
Consult
Tip
Consult
Tip
What is Oil Circuit Breaker?
Oil Circuit BreakerAn oil circuit breaker is a type of circuit breaker that utilizes oil as a dielectric or insulating medium for arc extinction. In an oil circuit breaker, the breaker's contacts are designed to separate within an insulating oil. When a fault occurs in theelectrical system, the contacts of the circuit breaker open beneath the insulating oil, and an arc is generated between them. The heat of this arc causes the surrounding oil to vaporize. Oil circuit breakers are classified into
04/14/2025
Consult
Tip
Consult
Tip
Lightning impulse voltage withstand test for circuit breakers
Lightning impulse voltage (LIWL) tests and switching impulse voltage tests are carried out to assess the dielectric stress resulting from transient over - voltages induced by lightning strikes and switching operations respectively. An impulse voltage generator produces a steep - front voltage waveform, which is then applied to the test object. A measurement system, consisting of a voltage divider and a digital recorder, is used to measure and analyze the test voltages and their waveforms.The fig
03/27/2025
Consult
Tip
Consult
Tip
Three phase high power synthetic current injection test methods for circuit breakers
This test just apply to 3 pole operation circuit breakers.As Fig these circuits use a three-phase current source and, generally, two voltage sources. one voltage source provides the TRV for the first pole-to-clear and the other gives the recovery voltage for the second- and third poles-to-clear, in the case where these poles clear simultaneously as in non-effectively earthed systems.This system have following components: A three phase current source (G) Voltage source 1 with current injection pa
03/26/2025
Consult
Tip
Consult
Tip
Dynamic (contact) resistance measurements (DRM) test on circuit breakers
This test serves to ascertain the length and condition of the current - carrying section of the arcing contacts within SF6 circuit breakers. DRM (Dynamic Resistance Measurement) tests are carried out by passing DC current through the breaker's main contacts during the breaker's operation. Subsequently, the breaker analyser computes and plots the resistance as a function of time. When contact movement is concurrently recorded, the resistance at each contact position can be determined. Through DRM
03/17/2025
Consult
Tip
Consult
Tip
Low temperature ambient effect for outdoor vacuum circuit breaker (VCB) operation
The vacuum arc - interrupting performance relies on the arcing within the metal vapor, which is generated from the contact material. Significantly, this process remains unaffected by low temperatures.A vacuum interrupter is typically fabricated from metals and ceramics and undergoes brazing at approximately 800 degrees Celsius. The material characteristics of both metal and ceramic, as well as the brazed joints between them, are inherently resistant to low - temperature impacts.Sliding guides ar
03/06/2025
Consult
Tip
Consult
Tip
Timing tests method in switchgears
Timing tests serve the purpose of determining the durations for operations such as opening (tripping), closing, close - opening, and reclosing. These time measurements are crucial for ensuring the safe and reliable operation of circuit breakers, thus being a key outcome of proper circuit breaker design.The main contact times are verified after production, during commissioning, and while the circuit breaker is in - service as part of periodic maintenance. To conduct these tests, timing test devic
03/05/2025
Consult
Tip
Consult
Tip
Online condition monitoring device (OLM2) on high voltage Circuit Breakers
This device is capable of monitoring and detecting various parameters according to the specifications outlined:SF6 Gas Monitoring: Utilizes a specialized sensor for measuring SF6 gas density. Capabilities include measuring gas temperature, monitoring SF6 leak rates, and calculating the optimal date for refilling.Mechanical Operation Analysis: Measures operational times for closing and opening cycles. Evaluates primary contacts separation speed, damping, and contact overtravel. Identifies signs o
02/13/2025
Consult
Tip
Consult
Tip