Access free engineering resources from IEE Business—covering power design, circuit layout, equipment selection, and troubleshooting. Expert-developed guides help engineers, procurement, and project teams make better decisions. Stay ahead on smart grids, renewables, efficiency, and AI tools. Improve reliability, reduce downtime, and enhance outcomes with real-world solutions. Explore our knowledge hub today.
Relays and circuit breaker combination
Operation Mechanism of a Circuit BreakerEnergy Storage and ReleaseA closed circuit breaker (CB) stores sufficient energy in one form or another to open its contacts. When a protective relay signals to open the circuit, this stored energy is released, causing the circuit breaker to trip and open.Connection Between Relay and Circuit BreakerExcept in special cases where protective relays are mounted directly on the breaker, the connection between the relay and the circuit breaker is typically achie
01/23/2025
Consult
Tip
Consult
Tip
Energisation of back to back(b to b) cables by circuit breaker according to IEC
The energization of a cable by the closing of a circuit breaker (CB) indeed results in a transient inrush current. The characteristics of this inrush current are influenced by several factors within the electrical system. Here is a refined and detailed explanation:Factors Influencing Inrush CurrentApplied Voltage: The voltage level at the moment the CB closes directly affects the magnitude of the inrush current. Higher voltages can lead to higher initial current peaks.Cable Surge Impedance: This
01/22/2025
Consult
Tip
Consult
Tip
How do ground fault circuit interrupters (GFCIs) protect people from electrical shock?
A Ground Fault Circuit Interrupter (GFCI) protects people from electric shock by continuously monitoring the electrical current in a circuit. Its operation principle is as follows:1. Monitoring Current Balance: Inside a GFCI device, there is a current transformer or similar sensor that monitors the current in both the hot (live) wire and the neutral wire simultaneously. Under normal conditions, the current in these two wires should be equal but opposite in direction; the current flowing into the
01/21/2025
Consult
Tip
Consult
Tip
Principle of controlled switching (CS) in circuit breaker
Controlled Switching (CS) MethodControlled Switching (CS) is a technique used to eliminate harmful transients by precisely timing the switching operations of circuit breakers (CBs). The closing or opening commands to the CB are delayed in such a way that the contacts make or separate at an optimal phase angle, minimizing transient effects.Key Principles: Voltage Zero Crossing for Closing: To avoid switching transients, the moment of contact closure should ideally occur at the voltage zero crossi
01/21/2025
Consult
Tip
Consult
Tip
Circuit breakers density Monitoring System (including piping) failures in substation
SF6 Gas Density Monitoring System Components and Failure ModesThe SF6 gas density monitoring system comprises three main components: Gas Density Monitor Gas Pipes with Manifold (if applicable) Pressure (or Density) GaugeEach of these components can experience different types of failure modes.Gas Density MonitorGas density monitors are susceptible to several failure modes:• Mechanical Disturbances: The operational density values at which the switch operates can change due to mechanical s
01/20/2025
Consult
Tip
Consult
Tip
What is the earth fault overcurrent relay in a substation?
What is a Ground Fault Overcurrent Relay in a Substation?A ground fault overcurrent relay is a protective device used to detect and protect against ground faults (also known as earth faults or single-phase ground faults) in power systems. It plays a crucial role in substations, ensuring the safety and reliability of the system.1. Working PrincipleThe primary function of a ground fault overcurrent relay is to monitor current imbalances in the power system, particularly detecting zero-sequence cur
01/18/2025
Consult
Tip
Consult
Tip
Switchgear operating mechanism material and important specifications
Special Considerations for Shaft and Latch BearingsSpecial attention must be paid to the material specifications and design of shaft and latch bearings to ensure smooth operation, even after prolonged periods of inactivity. The moving contacts should still separate within approximately 25 milliseconds when the protection system issues an opening command.Key Design Features:Trip and Close Latches: These components are designed to be relatively lightly loaded to minimize the burden on trip and clo
01/18/2025
Consult
Tip
Consult
Tip
Pole discrepancy definition in circuit breaker
Pole Discrepancy in Circuit BreakersPole discrepancy typically refers to differences in operating times between the three phases or poles of a switching device during the same operation. These discrepancies can affect the synchronization of the circuit breaker's poles, which is crucial for reliable operation.Challenges in Continuous MonitoringDetermining pole discrepancy on a continuous basis can be less accurate because it often relies on break time or make time recordings obtained through curr
01/17/2025
Consult
Tip
Consult
Tip
Online monitoring of high voltage circuit breaker parameters with optical fibre techniques
Sensing PrinciplesSensing principles involve detecting changes in the state of light polarization due to various physical phenomena. These include:• Pockels Effect: Changes in polarization caused by an electric field.• Faraday Effect: Changes in polarization caused by a magnetic field.• Photoelasticity: Changes in polarization due to mechanical stress.• Thermochromic Effects: Changes in light characteristics due to temperature variations.• Mechan
01/17/2025
Consult
Tip
Consult
Tip
Small inductive current switching condition for switchgear
Current Chopping and Reignition in Circuit Breakers Handling Small Inductive CurrentsWhen a circuit breaker (CB) opens or closes shunt reactor banks or unloaded power transformers, it typically switches small inductive currents, usually several tens of amperes, with a 90-degree lag relative to the voltage phase. However, these currents are often prematurely forced to zero by a phenomenon known as current chopping. This can result in chopping overvoltages and subsequent reignition overvoltages, w
01/14/2025
Consult
Tip
Consult
Tip