Free Expert Guides on Power Systems, Circuit Design & Electrical Troubleshooting

Access free engineering resources from IEE Business—covering power design, circuit layout, equipment selection, and troubleshooting. Expert-developed guides help engineers, procurement, and project teams make better decisions. Stay ahead on smart grids, renewables, efficiency, and AI tools. Improve reliability, reduce downtime, and enhance outcomes with real-world solutions. Explore our knowledge hub today.
Research and Application of Prefabricated Enclosure Structure for High-Voltage Compartments in Substations
The economic development demands higher efficiency in substation construction, giving rise to prefabricated cabin substation technology. With modular design, equipment wiring, commissioning, and prefabrication are completed in factories, requiring only "building-block" assembly on-site. Take the 10kV prefabricated high-voltage room as an example: equipment and cabin are installed in the factory, with on-site work limited to busbar and cabin assembly. The main transformer incoming line connects v
06/14/2025
Consult
Tip
Consult
Tip
Modular Intelligent Substation - Prefabricated Secondary Switchgear Integration Assembly
With the development of the national economy and society, the requirements for the quality and craftsmanship of power grid projects have become increasingly stringent. The need to improve the construction progress and quality of substations has created opportunities for the promotion of prefabricated cabin - type intelligent substations. The traditional on - site wiring and commissioning of secondary substation equipment involve a large amount of work. Moreover, on - site construction has to wai
06/13/2025
Consult
Tip
Consult
Tip
Application of Pre-integrated Prefabricated Substations in Renewable Energy Sector
Against the backdrop of profound changes in the global energy landscape and the booming development of the new energy industry, the construction mode of traditional substations struggles to meet the rapid deployment needs of new energy projects. The modular intelligent prefabricated cabin substation, leveraging its innovative advantages, has become a key direction for optimizing the new energy power system. In - depth exploration of its technical principles, industry adaptability, and applicatio
06/13/2025
Consult
Tip
Consult
Tip
Research on Reliability Enhancement Scheme Implementation for Modular Intelligent Prefabricated Substations
1 Implementation Strategies for the Scheme1.1 Deepen Survey and ResearchBefore constructing prefabricated cabin - type substations, it is necessary to conduct detailed surveys of local working conditions, clarify the construction scale and objectives, evaluate existing power facilities, plan projects, make up for infrastructure shortcomings, and adjust the construction rhythm. Meanwhile, control costs to avoid project suspension.1.2 Strengthen Structural ConstructionDuring promotion, multi - dim
06/13/2025
Consult
Tip
Consult
Tip
Comparative Analysis of 500 kV Prefabricated Substations vs. Conventional Substations
The secondary equipment area of conventional substations uses reinforced concrete or prefabricated steel structures, facing issues like long construction cycles, unreasonable functional zone design, strict environmental assessments, dust, noise, and disturbances. Primary and secondary equipment can only be installed after civil works and decoration, lowering construction efficiency.Prefabricated cabin substations integrate modularity, intelligence, and cost - effectiveness, boasting green, energ
06/13/2025
Consult
Tip
Consult
Tip
Operational Analysis of Prefabricated Enclosure Substations in Extreme Cold Climate Applications
Under global climate diversity, alpine power construction faces technical and environmental challenges. Extreme climates, complex geology, and long - term low winter temperatures, along with ice, snow, and storms, strain electrical equipment stability and power facility construction (schedule, cost, maintenance). Traditional on - site substations, with long construction and poor adaptability, can’t meet alpine regions’ fast, stable power needs.Prefabricated cabin substations,
06/13/2025
Consult
Tip
Consult
Tip
Implementation of Precast Foundations for Ring-Main Unit Compact Substations in Grid Modernization Initiatives
Compact substation boxes, with advantages like safe operation, high reliability, and easy maintenance, are used in urban grid construction/renovation. Structurally divided into American - style (high - cost, noisy, low - efficiency, gradually phased out) and European - style (large - sized but more advantages, still popular).To address their pros/cons, ring - network prefabricated ones were developed.I. Basic Materials for Prefabricated Compact Substation BoxesMaterials need hardness, strength,
06/13/2025
Consult
Tip
Consult
Tip
Analysis of the Technical Characteristics of Online Monitoring for Medium-Voltage Switchgear Status
With the increasing complexity of power system operation environment and the deepening of power system reform, traditional power grids are accelerating the transformation to smart grids. The goal of equipment condition-based maintenance is achieved through real-time perception of equipment status by new sensors, reliable communication via modern network technology, and effective monitoring by background expert systems.I. Analysis of Condition-based Maintenance StrategyCondition-based Maintenance
06/11/2025
Consult
Tip
Consult
Tip
Analysis of the Impact of Vacuum Arc Chamber Inspection and Maintenance on Improving the Reliability of Vacuum Circuit Breakers
Vacuum circuit breakers are widely used in distribution networks. As core components of power supply equipment, their performance hinges on both vacuum interrupters’ capabilities and circuit breakers’ mechanical characteristics (contact opening distance, stroke, pressure, average closing/opening speed, closing bounce time, opening - closing asynchronism, operation times, and cumulative allowable wear of contacts). Both are critical for reliable operation. The vacuum interrupt
06/09/2025
Consult
Tip
Consult
Tip
How to install the transition joint for the speed measurement rotating sensor of the 10 kV indoor vacuum circuit breaker?
1 Innovation BackgroundRegular mechanical characteristic tests (covering closing/opening time, speed, opening distance, over - travel, three - phase asynchrony, bouncing time, etc.) are crucial for 10 kV indoor vacuum circuit breakers, ensuring reliable power supply and grid stability. Manufacturers typically use the moving - contact linear sensor method for testing, as it accurately reflects performance via consistent motion curves between the linear transmission rod and moving contacts.To ease
06/09/2025
Consult
Tip
Consult
Tip
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.