Free Expert Guides on Power Systems, Circuit Design & Electrical Troubleshooting

Access free engineering resources from IEE Business—covering power design, circuit layout, equipment selection, and troubleshooting. Expert-developed guides help engineers, procurement, and project teams make better decisions. Stay ahead on smart grids, renewables, efficiency, and AI tools. Improve reliability, reduce downtime, and enhance outcomes with real-world solutions. Explore our knowledge hub today.
The design of the three-purpose grounding transformer
Underground Power Cable Transmission LinesDirect - buried power cable lines have large ground - distributed capacitance, causing high single - phase - to - ground short - circuit capacitive current. For 10 kV lines, if this current exceeds 10 A, arcs hardly self - extinguish, risking arc overvoltage and endangering line equipment. Arc extinction is thus necessary. With a Dyn - connected main transformer, an arc - suppression coil on the secondary neutral point suffices. For Yd - connected ones,
06/12/2025
Consult
Tip
Consult
Tip
Design Calculations for Neutral Grounding Schemes and Grounding Transformer Sizing in Utility-Scale Solar PV Plants
1 Classification of Neutral Grounding Methods for Solar Photovoltaic Power StationsInfluenced by differences in voltage levels and grid structures across regions, the neutral grounding methods of power systems are mainly categorized into non-effective grounding and effective grounding. Non-effective grounding includes neutral grounding via arc suppression coils and neutral ungrounded systems, while effective grounding comprises neutral solid grounding and neutral grounding via resistors. The sel
06/12/2025
Consult
Tip
Consult
Tip
Zero-Sequence Impedance Characterization of Dry-Type Grounding Transformer with ZN Connection
In a neutral-insulated three-phase power system, an earthing transformer provides an artificial neutral point, which can be solidly earthed or earthed via reactors/arc suppression coils. The ZNyn11 connection is typical, where zero-sequence magnetomotive forces in the inner/outer half-windings of the same core column cancel out, balancing fault currents in series windings and minimizing zero-sequence leakage flux/impedance.Zero-sequence impedance is critical: it determines fault current magnitud
06/12/2025
Consult
Tip
Consult
Tip
Discussion on the Design of Low Zero-Sequence Impedance Grounding Transformers
With the expansion of power system scale and the cableization process of urban power grids, the capacitive current in 6kV/10kV/35kV power grids has significantly increased (generally exceeding 10A). As power grids at this voltage level mostly adopt neutral ungrounded operation mode, and the distribution voltage side of main transformers is usually in delta connection, lacking a natural grounding point, the arc during ground faults cannot be reliably extinguished, necessitating the introduction o
06/11/2025
Consult
Tip
Consult
Tip
What components make up the design of medium-voltage ring network distribution switchgear?
As an expert who has been deeply engaged in the field of power system design for many years, I have always paid attention to the technological evolution and application practice of medium-voltage ring main distribution equipment. As a core electrical device in the secondary distribution link of the power system, the design and performance of such equipment are directly related to the safe and stable operation of the power supply network. The following is a professional analysis of the key design
06/11/2025
Consult
Tip
Consult
Tip
Design of Remote Closing Device for Indoor Handcart High-Voltage Vacuum Circuit Breaker
The cabling and undergrounding of urban power grid lines have become an irreversible trend in distribution network construction. High-voltage switchgear, as the core equipment of the distribution system, has become the main object of daily operation and maintenance for maintenance personnel. During the equipment iteration process, the comprehensive replacement and commissioning of new equipment have a long cycle, and a type of old hand-cranked high-voltage switchgear is still in service.Due to l
06/07/2025
Consult
Tip
Consult
Tip
Design and Development of WVT-12 Vacuum Circuit Breaker
I. Market and Technical ResearchSince 2003, I have been engaged in the key project of localizing WVT-12 vacuum circuit breaker technology for Anhui Longbo Company. At that time, in the 12kV voltage class, vacuum circuit breakers had occupied more than 98% of the total circuit breakers. With the advancement of power grid construction and the growth of industrial and residential electricity demand, the domestic and international markets have shown a continuous upward trend in the demand for advanc
06/07/2025
Consult
Tip
Consult
Tip
Design and Application of High-Voltage Reclosers: Focusing on 20kV Systems in Indonesia and Vietnam
1. IntroductionIn the modern power grid infrastructure, high - voltage reclosers play a pivotal role in enhancing the reliability and efficiency of power supply. This is particularly crucial in regions like Indonesia, which has a vast and complex power distribution network spanning numerous islands, and Vietnam, with its developing coastal power systems. The 20kV voltage level, falling within the medium - high - voltage range, is widely adopted in urban grids, industrial power supply, and certai
06/03/2025
Consult
Tip
Consult
Tip
High-Voltage Disconnect Switches and Operational Mechanism Failures
High-voltage disconnect switches (HVDs) are critical switching devices in power grids, primarily used to isolate power sources in conjunction with circuit breakers. With the proposal of "digital grids," continuous advancements in high-voltage switchgear technology, and the expansion of China's power grid, HVD applications have surged in both quantity and diversity. The electric operating mechanism, a vital component controlling HVD switching movements, demands exceptional reliability and stabili
05/29/2025
Consult
Tip
Consult
Tip
What is the research on the intelligent monitoring system for the operating status of high-voltage disconnectors?
1. IntroductionHigh voltage disconnect switches (HVDs), particularly 145kV models, are critical for power grid safety in Indonesia, where tropical climates and complex terrain pose unique operational challenges. This article presents an intelligent monitoring system (IMS) designed to address these challenges, integrating IP66 - rated environmental protection and compliance with IEC 60068 - 3 - 3. The system leverages sensor networks, data analytics, and remote control to enhance the reliability
05/28/2025
Consult
Tip
Consult
Tip
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.