Free Expert Guides on Power Systems, Circuit Design & Electrical Troubleshooting

Access free engineering resources from IEE Business—covering power design, circuit layout, equipment selection, and troubleshooting. Expert-developed guides help engineers, procurement, and project teams make better decisions. Stay ahead on smart grids, renewables, efficiency, and AI tools. Improve reliability, reduce downtime, and enhance outcomes with real-world solutions. Explore our knowledge hub today.
Regulations for Primary Wiring of Distribution Transformers
The primary wiring of transformers shall comply with the following regulations: Supports and Cable Protection Conduits: The construction of supports and cable protection conduits for transformer incoming and outgoing lines shall conform to design document requirements. Supports must be firmly installed with elevation and horizontal deviations within ±5mm. Both supports and protection conduits shall have reliable grounding connections. Rectangular Busbar Bending: When rectangular busbars are used
12/23/2025
Consult
Tip
Consult
Tip
Voltage Regulation Methods and Impacts of Distribution Transformers
Voltage Compliance Rate and Distribution Transformer Tap Changer AdjustmentThe voltage compliance rate is one of the main indicators for measuring power quality. However, due to various reasons, electricity consumption during peak and off-peak periods often differs significantly, causing the output voltage of distribution transformers to fluctuate. These voltage fluctuations adversely affect the performance, production efficiency, and product quality of various electrical equipment to varying de
12/23/2025
Consult
Tip
Consult
Tip
Causes and Solutions for High Failure Rate of Distribution Transformers
1. Causes of Failure in Agricultural Distribution Transformers(1) Insulation DamageRural power supply typically utilizes 380/220V mixed supply systems. Due to the high proportion of single-phase loads, distribution transformers often operate under significant three-phase load imbalance. In many cases, the imbalance exceeds the permissible range specified in standards, causing premature aging, deterioration, and failure of transformer winding insulation, ultimately leading to burnout.When distrib
12/23/2025
Consult
Tip
Consult
Tip
Analysis of Transformer Grounding Protection Technology in Construction Sites
Currently, China has achieved certain accomplishments in this field. Relevant literature has designed typical configuration schemes for grounding fault protection in nuclear power plant low-voltage distribution systems. Based on the analysis of domestic and international cases where grounding faults in nuclear power plant low-voltage distribution systems have caused maloperation of transformer zero-sequence protection, the underlying causes have been identified. Furthermore, improvement suggesti
12/13/2025
Consult
Tip
Consult
Tip
Analysis of Diagnostic Methods for Core Grounding Faults in 35 kV Distribution Transformers
35 kV Distribution Transformers: Core Grounding Fault Analysis and Diagnostic Methods35 kV distribution transformers are common critical equipment in power systems, carrying important electrical energy transmission tasks. However, during long-term operation, core grounding faults have become a major issue affecting the stable operation of transformers. Core grounding faults not only impact transformer energy efficiency and increase system maintenance costs, but may also trigger more serious elec
12/13/2025
Consult
Tip
Consult
Tip
Application of 10kV Reclosers and Sectionalizers in Rural Distribution Networks
1 Current Grid StatusWith the continuous deepening of rural power grid transformation, the health level of rural grid equipment is constantly improving, and power supply reliability basically meets user needs. However, regarding the current grid status, due to funding constraints, ring networks have not been implemented, dual power supplies are unavailable, and lines adopt a single radial tree-like power supply method. This resembles a tree trunk with many branches—meaning the lines have numerou
12/11/2025
Consult
Tip
Consult
Tip
Chinese Grid Technology Reduces Egyptian Power Distribution Losses
On December 2nd, the South Cairo distribution network loss reduction pilot project in Egypt, led and implemented by a Chinese power grid company, officially passed the acceptance inspection by the South Cairo Electricity Distribution Company of Egypt. The comprehensive line loss rate in the pilot area decreased from 17.6% to 6%, achieving an average daily reduction of lost electricity of approximately 15,000 kilowatt-hours. This project is the first overseas distribution network loss reduction p
12/10/2025
Consult
Tip
Consult
Tip
Low-Voltage Distribution Lines and Power Distribution Requirements for Construction Sites
Low-voltage distribution lines refer to the circuits that, through a distribution transformer, step down the high voltage of 10 kV to the 380/220 V level—i.e., the low-voltage lines running from the substation to the end-use equipment.Low-voltage distribution lines should be considered during the design phase of substation wiring configurations. In factories, for workshops with relatively high power demand, dedicated workshop substations are often installed, where transformers supply power direc
12/09/2025
Consult
Tip
Consult
Tip
H59/H61 Transformer Failure Analysis and Protection Measures
1.Causes of Damage to Agricultural H59/H61 Oil-Immersed Distribution Transformers1.1 Insulation DamageRural power supply commonly uses a 380/220V mixed system. Due to the high proportion of single-phase loads, H59/H61 oil-immersed distribution transformers often operate under significant three-phase load imbalance. In many cases, the degree of three-phase load imbalance far exceeds the limits permitted by operational regulations, causing premature aging, deterioration, and eventual failure of th
12/08/2025
Consult
Tip
Consult
Tip
Top 5 Faults Found in H61 Distribution Transformers
Five Common Defects of H61 Distribution Transformers1.Lead Wire DefectsInspection Method: The three-phase DC resistance imbalance rate significantly exceeds 4%, or one phase is essentially open-circuited.Remedial Measures: The core should be lifted for inspection to locate the defective area. For poor contacts, re-polish and tighten the connection. Poorly welded joints should be re-welded. If the welding surface area is insufficient, it should be enlarged. If the lead wire cross-section is inade
12/08/2025
Consult
Tip
Consult
Tip