• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


Free Expert Guides on Power Systems, Circuit Design & Electrical Troubleshooting

Access free engineering resources from IEE Business—covering power design, circuit layout, equipment selection, and troubleshooting. Expert-developed guides help engineers, procurement, and project teams make better decisions. Stay ahead on smart grids, renewables, efficiency, and AI tools. Improve reliability, reduce downtime, and enhance outcomes with real-world solutions. Explore our knowledge hub today.
Solving the Contradiction in Arc Suppression Coil Grounding: Damping Resistor Applications and Tuning Strategies
Contradiction PointsIn automatic tracking arc suppression coils, the adjustment precision is high, the residual current is small, and the operation is close to the resonance point.In an automatic tracking arc suppression coil grounding system, two factors must be considered: Under normal operating conditions, the long-term voltage displacement of the neutral point should not exceed 15% of the system's nominal phase voltage; In the case of a ground fault, the grounding residual current should b
07/28/2025
Consult
Tip
Consult
Tip
What Are the Common Types and Characteristics of Distribution Network Overvoltage?
Distribution networks, characterized by their wide distribution, large number of equipment, and low insulation level, are prone to insulation accidents caused by overvoltage. This not only reduces the stability of the entire distribution system and the insulation performance of the lines but also has a significant adverse impact on the safe operation of the power grid and the healthy and sustainable development of the power industry.From a circuit perspective, apart from the power source, the po
07/21/2025
Consult
Tip
Consult
Tip
What is Available Fault Current?
What is Available Fault Current?Available Fault Current DefinitionAvailable Fault Current (AFC) is defined as the maximum current available during a fault condition, also known as available short-circuit current.Importance of AFC MarkingAFC must be marked with a calculation date as per the 2011 NFPA 70: NEC section 110.24.Fault Current CalculationTo calculate fault current, use the system voltage, conductor constant, and length of the service entrance conductor. Find the system voltage (E_{L-L})
08/05/2024
Consult
Tip
Consult
Tip
Electric Cable Faults
Cable Faults DefinitionCable faults are issues in electric cables that disrupt the flow of electricity, including short circuits, earth faults, and open circuits.Causes of Cable FaultsFaults can be caused by damaged insulation due to water, moisture, ageing, or improper handling.Fault Type There may be a short circuit between two conductors, There may be earth fault, i.e., fault between conductor and ground, There may be open circuit caused due to disconnection of the conductor.Detection Methods
07/24/2024
Consult
Tip
Consult
Tip
A Review of Current-Limiting Control of Grid-Forming Inverters Under Symmetrical Disturbances
Grid-forming (GFM) inverters are recognized as a viable solution to increase the penetration of renewable energy in bulk power systems. However, they are physically different from synchronous generators in terms of overcurrent capability. To protect the power semiconductor devices and support the power grid under severe symmetrical disturbances, the GFM control systems should be able to achieve the following requirements: current magnitude limitation, fault current contribution, and fault reco
03/07/2024
Consult
Tip
Consult
Tip
Dual Fuzzy-Sugeno Method to Enhance Power Quality Performance Using a Single-Phase Dual UPQC-Dual PV Without DC-Link Capacitor
This paper proposes a novel configuration of a dual UPQC supplied by a dual photovoltaic (PV), hereinafter referred to as 2UPQC-2PV,to improve the power quality performance of a single-phase 220 V/50 Hz distribution system. The 2UPQC-2PV configuration is proposed to anticipate the possible failure of both inverters in one of the UPQC circuits. The PV array replaces the DC-link capacitor to maintain its voltage connected to the DC-link of the UPQC constant while at the same time supplying active
03/06/2024
Consult
Tip
Consult
Tip
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.