• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


Free Expert Guides on Power Systems, Circuit Design & Electrical Troubleshooting

Access free engineering resources from IEE Business—covering power design, circuit layout, equipment selection, and troubleshooting. Expert-developed guides help engineers, procurement, and project teams make better decisions. Stay ahead on smart grids, renewables, efficiency, and AI tools. Improve reliability, reduce downtime, and enhance outcomes with real-world solutions. Explore our knowledge hub today.
High Voltage Bushing Selection Standards for Power transformer
1. Structure Forms and Classification of BushingsThe structure forms and classification of bushings are shown in the table below: Serial No. Classification Feature Category 1 Main insulation structure Capacitive Type Resin-impregnated paperOil-impregnated paper Non-capacitive Type Gas insulationLiquid insulationCasting resinComposite insulation 2 External Insulation Material PorcelainSilicone Rubber 3 Filling Material Between Capacitor Core and Exte
12/20/2025
Consult
Tip
Consult
Tip
Chinese Gas-Insulated Switchgear Enables Commissioning of Longdong-Shandong ±800kV UHV DC Transmission Project
On May 7, China's first large-scale integrated wind-solar-thermal-storage comprehensive energy base UHV transmission project—the Longdong~Shandong ±800kV UHV DC transmission project—was officially energized and put into operation. The project has an annual transmission capacity exceeding 36 billion kilowatt-hours, with new energy sources accounting for more than 50% of the total. After commissioning, it will reduce carbon dioxide emissions by approximately 14.9 million tons annually, contributin
12/13/2025
Consult
Tip
Consult
Tip
High-Voltage SF₆-Free Ring Main Unit: Adjustment of Mechanical Characteristics
(1) The contact gap is primarily determined by insulation coordination parameters, interruption parameters, contact material of the high-voltage SF₆-free ring main unit, and the design of the magnetic blowout chamber. In practical application, a larger contact gap is not necessarily better; instead, the contact gap should be adjusted as close as possible to its lower limit to reduce operating energy consumption and extend service life.(2) The determination of contact overtravel is related to fac
12/10/2025
Consult
Tip
Consult
Tip
World’s First 500kV/90kA Cost-Effective AC Current Limiter: R&D Success & Grid Trial
Recently, the world’s first 500kV/90kA cost-effective high-voltage AC current limiter, jointly led by Guangzhou Power Supply Bureau of Guangdong Power Grid and developed by China High-Voltage AC Current Limiter Manufacturer, successfully completed artificial short-circuit tests and has been officially connected to the grid for trial operation on the Shunguang Jia Line at the 500kV Guangnan Substation. As a key project under China’s National Key R&D Program, the successful completion of the “
11/27/2025
Consult
Tip
Consult
Tip
Research and Analysis on Drone-Based Replacement Technologies for Ultra-High-Voltage Transmission Line Maintenance
In a certain region, after maintenance of ultra-high-voltage (UHV) transmission lines, the following issues were identified: existing drones lack sufficient performance to meet the current large-scale and extensive inspection and maintenance demands of UHV lines. In practical operations, drones exhibit inadequate endurance, limited image acquisition capability, and poor electromagnetic interference (EMI) resistance, which negatively impacts inspection effectiveness and prevents accurate identifi
11/18/2025
Consult
Tip
Consult
Tip
Development of a Lifting Device for High-Voltage Disconnectors in Complex Environments
In power systems, high-voltage disconnectors in substations have suffered from aging infrastructure, severe corrosion, increasing defects, and insufficient current-carrying capacity of the main conductive circuit, significantly compromising power supply reliability. There is an urgent need to carry out technical retrofits on these long-in-service disconnectors. During such retrofits, to avoid interrupting customer power supply, the common practice is to place only the retrofit bay under maintena
11/13/2025
Consult
Tip
Consult
Tip
Corrosion and Protective Practices of High-Voltage Disconnectors
High-voltage disconnectors are extremely widely used, and therefore people pay great attention to potential problems that may arise with them. Among various faults, corrosion of high-voltage disconnectors is a major concern. In light of this situation, this article analyzes the composition of high-voltage disconnectors, types of corrosion, and faults caused by corrosion. It also investigates the causes of disconnector corrosion and studies theoretical foundations and practical techniques for cor
11/13/2025
Consult
Tip
Consult
Tip
Research on the Application of a Remote Online Defect Elimination System for High-Voltage Disconnector Contacts
High-voltage disconnectors, also known as isolator switches or knife switches, feature a simple working principle and convenient operation. As commonly used high-voltage switching equipment, they significantly impact the operational safety of substations, demanding stringent reliability in practical applications. The remote online defect-elimination system for high-voltage disconnector contacts offers advantages such as ease of operation, low operating costs, and high stability, making it well-s
11/11/2025
Consult
Tip
Consult
Tip
Application of High-Voltage Disconnectors in Traction Power Supply Systems
Traditional switches have become increasingly inadequate for the operational demands of modern traction power supply systems. The emergence of high-voltage disconnectors has effectively filled this gap. High-voltage disconnector systems optimize the structure of conventional switches, broaden their applicability, and place greater emphasis on fine details, thereby enhancing the safety and reliability of power systems during actual operation. Therefore, it is essential to analyze and study the ap
11/11/2025
Consult
Tip
Consult
Tip
Fault Handling of High-Voltage Disconnector Failure to Open at a 110 kV Substation
According to relevant regulations, high-voltage disconnectors are permitted to perform the following operations: Switching (opening/closing) normally operating potential transformers (PTs) and surge arresters; Switching the neutral grounding disconnector of a main transformer under normal operating conditions; Switching small-current loops to balance circulating currents.A high-voltage disconnector is an electrical component without arc-quenching capability. Therefore, it may only be operated wh
11/11/2025
Consult
Tip
Consult
Tip
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.