Access free engineering resources from IEE Business—covering power design, circuit layout, equipment selection, and troubleshooting. Expert-developed guides help engineers, procurement, and project teams make better decisions. Stay ahead on smart grids, renewables, efficiency, and AI tools. Improve reliability, reduce downtime, and enhance outcomes with real-world solutions. Explore our knowledge hub today.
Digital Fault Recorders (DFR) monitoring method for switchgears
Digital Fault Recorder (DFR) System for Circuit Breaker MonitoringThe Digital Fault Recorder (DFR) system is designed to record current and voltage oscillograms during every circuit breaker switching operation. It captures data for a time period of approximately three to five seconds around the moment of switching. Once collected, this data is transmitted to a server, where specialized software conducts in - depth analysis. This monitoring approach can be implemented in any switchgear equipped w
05/05/2025
Consult
Tip
Consult
Tip
Important points in engineering studies in high voltage gas insulated switchgear (GIS)
Important points in engineering studies in high voltage gas insulated switchgear (GIS)Engineering Studies in Gas - insulated Switchgear (GIS)Once the electrical engineer has defined the preliminary configuration of the GIS and determined and specified the primary equipment data, additional studies related to the engineering aspects, as well as the logistics of delivery and installation, must be carried out.The most crucial engineering studies are summarized as follows:1. Transient Recovery Volta
04/06/2025
Consult
Tip
Consult
Tip
SF6 decomposition products from electrical arc in gas switchgear
During the switching of normal load or short-circuit current, SF₆ molecules are ionized and fragmented by the arc. The figure illustrates the main reaction processes and the locations where each process is likely to occur. SF₄, as the primary decomposition product resulting from the electric discharge, first reacts with H₂O on the inner wall surface, giving rise to SOF₂. The metal fluorides remain in the form of powder or dust on the surface. H₂O is released in this reaction and thus becomes ava
03/19/2025
Consult
Tip
Consult
Tip
Trending method in switchgear control and auxiliary circuits visual check
The trending method involves verifying whether a signal lies within the normal range, exhibits consistent behavior in relation to other information, and does not show signs of drifting or abnormal fluctuations. Here are some examples:1. Operating environmental conditionsMonitoring temperature and humidity levels. Deviations from the normal range can impact the performance of electrical and mechanical components.2. Circuit breaker mechanical operation counterAutomation data is used to monitor the
03/10/2025
Consult
Tip
Consult
Tip
What are smart switchgears?
What is a smart switchgear?A smart switchgear is a kind of electrical equipment that integrates advanced sensor technology, communication technology, automatic control technology, and intelligent analysis technology, etc., to carry out intelligent upgrades on traditional switchgears. It is mainly used for the distribution, control, and protection of electrical energy in the power system. The following is a detailed introduction from aspects such as its functional characteristics, structural comp
01/24/2025
Consult
Tip
Consult
Tip
Important points for SF6 gas leakage on-site test for high voltage switchgear
SF6 Gas Leakage Testing on SitePurposeSF6 gas leakage testing is conducted to ensure that there are no gas leaks at the field-assembled joints of Gas-Insulated Switchgear (GIS). Leaks can occur during field assembly due to various factors such as damaged sealing surfaces, improper placement, incorrect application of seals, seal damage or omission, improper application of lubricants and sealants, misalignment or inadequate tightening of mating surfaces, and contamination.Scope Exclusions: There i
12/03/2024
Consult
Tip
Consult
Tip
Layout of 10kV closed high voltage switchgear
Layout of 10kV closed high voltage switchgear(a)single-row(b)double-row(c)Single row layout(d)double row layout
Consult
Tip
Consult
Tip