• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


Free Expert Guides on Power Systems, Circuit Design & Electrical Troubleshooting

Access free engineering resources from IEE Business—covering power design, circuit layout, equipment selection, and troubleshooting. Expert-developed guides help engineers, procurement, and project teams make better decisions. Stay ahead on smart grids, renewables, efficiency, and AI tools. Improve reliability, reduce downtime, and enhance outcomes with real-world solutions. Explore our knowledge hub today.
Six Key Differences Between Ring Main Units and Switchgear Explained
Differences Between Ring Main Units (RMUs) and SwitchgearIn power systems, both ring main units (RMUs) and switchgear are common distribution equipment, but they differ significantly in function and structure. RMUs are primarily used in ring-fed networks, responsible for power distribution and line protection, with the key feature being multi-source interconnection through a closed-loop ring network. Switchgear, as a more general-purpose distribution device, handles power reception, distribution
10/28/2025
Consult
Tip
Consult
Tip
Designing Reliable 24kV Air & Gas-Insulated Gear
Currently, China's medium-voltage distribution networks predominantly operate at 10kV. With rapid economic development, power loads have surged, increasingly exposing the limitations of the existing power supply methods. Due to the outstanding advantages of 24kV high-voltage switchgear in meeting higher load capacity demands, it has quietly gained traction within the industry. Following the State Grid Corporation's "Notice on Promoting the 20kV Voltage Level," the 20kV voltage class has seen a r
10/28/2025
Consult
Tip
Consult
Tip
Maintenance and Repair Items for 10kV High-Voltage Switchgear
I. Routine Maintenance and Inspection(1) Visual Inspection of Switchgear Enclosure No deformation or physical damage to the enclosure. Protective paint coating shows no severe rust, peeling, or flaking. Cabinet is securely installed, clean on the surface, and free of foreign objects. Nameplates and identification labels are neatly affixed and not falling off.(2) Check of Switchgear Operating Parameters Instruments and meters indicate normal values (comparable to typical operating data, with no s
10/24/2025
Consult
Tip
Consult
Tip
Can X-ray Technology Detect Hidden Switchgear Defects?
Advancing Power Equipment Diagnostics: The Role of X-ray Digital ImagingWith continuous advancements in power grid equipment research and manufacturing, an increasing number of new devices are being integrated into power systems. As a result, effective monitoring of in-service equipment has become critically important for ensuring grid reliability and safety.The introduction and successful application of X-ray digital imaging technologies—specifically Computed Radiography (CR) and Digital Radiog
10/24/2025
Consult
Tip
Consult
Tip
Design of New-Type Power Distribution Cabinets
In modern electrical engineering, distribution cabinets and distribution boxes serve as the "nerve centers" for power distribution and control. Their design quality directly determines the safety, reliability, and cost-effectiveness of the entire power supply system. With increasingly complex power demands and rising levels of intelligence, the design of distribution equipment has evolved from simply "housing electrical components" into a comprehensive systems engineering task integrating struct
10/17/2025
Consult
Tip
Consult
Tip
Optimal Cabinet Selection for Power Distribution Rooms
【Abstract】 In urbanization construction, the power system is the most fundamental electrical facility and a critical energy source. To ensure the safety and stability of the power supply during the operation of the power system, it is essential to scientifically and rationally select the high and low voltage distribution cabinets in distribution rooms. This ensures the safety and reliability of the distribution cabinets' operation while making the configuration more scientific, economical, and r
10/17/2025
Consult
Tip
Consult
Tip
Optimal Selection of High and Low Voltage Distribution Cabinets in Distribution Rooms
Abstract: Based on the analysis of the main types and characteristics of high and low voltage distribution cabinets in distribution rooms, this paper discusses the basic principles for selecting these cabinets. From the perspectives of technical reliability, installation convenience, and economy, the optimization measures for selecting high and low voltage distribution cabinets are analyzed, which plays a certain role in improving their technical and economic performance.Keywords: Distribution R
10/17/2025
Consult
Tip
Consult
Tip
Next-Gen Air-Insulated Switchgear for Smart Grids
Technical FieldThe utility model relates to the technical field of ring main units, specifically an air-insulated intelligent vacuum ring main unit.Background ArtA ring main unit is an electrical device that integrates high-voltage switchgear into a metal enclosure or assembles it into a interval-type ring main power supply unit. It forms a system by connecting the busbars of various outgoing feeder cabinets, with its core comprising load switches and fuses. It features simple structure, small s
10/16/2025
Consult
Tip
Consult
Tip
What Is a Ring Main Unit? Types & Benefits
1. Product OverviewA Ring Main Unit (RMU) is an electrical apparatus composed of high-voltage switching equipment enclosed in a metal or non-metal insulated cabinet, or configured as modular compartments forming a ring-type power supply unit. Its core components typically include load switches and fuses, offering advantages such as simple structure, compact size, low cost, improved power parameters and performance, and enhanced power supply safety.RMUs are widely used in distribution substations
10/15/2025
Consult
Tip
Consult
Tip
Cabinet Structure and Process Characteristics of Low-Voltage Switchgear
I. IntroductionThe cabinet structure forms the fundamental basis of low-voltage switchgear, making cabinet manufacturing technology the foundation of all foundations. As a structural enclosure, the cabinet must not only meet the functional integration requirements of various electrical units (such as standardized types, modular combinations, and functional distribution), but also satisfy inherent cabinet requirements (such as robustness, reliability, neat appearance, and ease of adjustment). Due
10/10/2025
Consult
Tip
Consult
Tip
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.