Access free engineering resources from IEE Business—covering power design, circuit layout, equipment selection, and troubleshooting. Expert-developed guides help engineers, procurement, and project teams make better decisions. Stay ahead on smart grids, renewables, efficiency, and AI tools. Improve reliability, reduce downtime, and enhance outcomes with real-world solutions. Explore our knowledge hub today.
Transient Recovery Voltage(TRV) in Interruption of Small Inductive Currents by Circuit Breakers
Analyzing Transient Phenomena in Linear Systems Using the Principle of SuperpositionIn analyzing transient phenomena caused by switching operations in linear systems, the principle of superposition is a powerful tool. By combining the steady-state solution that existed before the open-circuit operation with the transient responses induced by short-circuit voltage sources and open-circuit current sources, and considering the current injected through the switch contacts, a comprehensive descriptio
12/11/2024
Consult
Tip
Consult
Tip
AC Circuit Breakers Routine Tests according to IEC 62271-100
To ensure the superior quality and performance of each AC circuit breaker in terms of materials, design, and assembly, manufacturers perform routine tests on every unit produced. These tests are essential for verifying the reliability and safety of the circuit breakers, confirming their ability to function correctly under specified conditions.For multi-phase circuit breakers consisting of multiple breaker units (such as V-type or T-type configurations), routine testing is conducted on the fully
12/10/2024
Consult
Tip
Consult
Tip
High voltage Incoming and outgoing feeders configuration in switch yards
The incoming and outgoing feeders of switchgear cabinets are typically equipped with circuit breakers, isolating switches, and earthing switches to ensure the safe operation of the power system. In high-voltage switch stations, each feeder is also fitted with current transformers (CTs) and potential transformers (PTs) to connect protection and measurement devices. CTs are positioned on the busbar side of the PTs to allow protection devices to detect short circuits in the PTs. For feeders without
12/09/2024
Consult
Tip
Consult
Tip
Out of phase current switching in High Voltage Circuit Breakers
When two parts of an electrical network with the same operating voltage are coupled, a phase displacement switching phenomenon occurs if their equivalent sources have different phase angles, with some or all phases being 180° out of phase. During the switching operation, the circuit breaker encounters source voltages with differing phase angles, leading to the presence of phase-displaced currents in the connection. These currents must be reliably interrupted by the circuit breakers on bo
12/07/2024
Consult
Tip
Consult
Tip
How can you explain DC bias with voltage feedback?
How to Explain DC Bias Using Voltage FeedbackDC bias (Direct Current bias) refers to the application of a stable DC voltage or current in a circuit to ensure that active components, such as transistors or operational amplifiers, operate within their linear region or at a specific operating point. In the context of voltage feedback systems, the concept of DC bias can be explained through several key aspects:1. What is Voltage Feedback?Voltage feedback is a negative feedback mechanism where a port
12/06/2024
Consult
Tip
Consult
Tip
Contact Nozzle Ablation in high voltage sf6 circuit breaker
Inspection and Maintenance of High-Voltage SF6 Circuit Breaker Nozzles1.Background and Traditional Inspection MethodsHigh-voltage SF6 circuit breakers are widely used in power systems to protect circuits from short circuits and overloads. To ensure their reliability and safety, manufacturers typically require periodic disassembly and visual inspection of the main contacts, arc contacts, and gas nozzles. These inspections aim to assess the wear condition of these components and determine whether
12/06/2024
Consult
Tip
Consult
Tip
Brief History of the Past and Present of High voltage Vacuum Circuit Breakers
High Voltage Vacuum Circuit Breakers: An OverviewIntroductionHigh voltage vacuum circuit breakers (HV VCBs) have emerged as a viable alternative to traditional SF6 gas-insulated circuit breakers, particularly in applications where frequent switching and lower maintenance costs are critical. Since 2014, HV VCBs have been increasingly adopted as an alternative to high-voltage gas circuit breakers, offering a greener and more sustainable solution by eliminating the use of SF6, a potent greenhouse g
12/05/2024
Consult
Tip
Consult
Tip
Phenomena created during switching of no-load transformers by AIS high voltage disconnect switch
Introduction to High-Voltage Isolators Difference Between High-Voltage Circuit Breakers and Earthing SwitchesHigh-Voltage Circuit Breaker (Circuit Breaker) and Earthing Switch are two different mechanical switching devices, each playing a crucial role in power systems. High-Voltage Circuit Breaker: It is primarily used to indicate whether a circuit is open or closed. The circuit breaker has the capability to interrupt current, allowing it to cut off large currents under live conditions and maint
12/04/2024
Consult
Tip
Consult
Tip
Important points for SF6 gas leakage on-site test for high voltage switchgear
SF6 Gas Leakage Testing on SitePurposeSF6 gas leakage testing is conducted to ensure that there are no gas leaks at the field-assembled joints of Gas-Insulated Switchgear (GIS). Leaks can occur during field assembly due to various factors such as damaged sealing surfaces, improper placement, incorrect application of seals, seal damage or omission, improper application of lubricants and sealants, misalignment or inadequate tightening of mating surfaces, and contamination.Scope Exclusions: There i
12/03/2024
Consult
Tip
Consult
Tip
Description of the basic phenomena during circuit breaker switching in grids
Circuit breaker switching terminology can be understood by considering an actual event.Figures 1 to 3 show the trace of a close-open (CO) three-phase unearthed fault current test on a vacuum circuit breaker (trace courtesy of KEMA).Taking each figure in turn, the terminology is as follows:Circuit Breaker Tripping Sequence and Related QuantitiesFrom Figure 1, we can observe the following sequence of events in detail:1.Initial State: The circuit breaker starts in the open position. A closing signa
12/03/2024
Consult
Tip
Consult
Tip