Free Expert Guides on Power Systems, Circuit Design & Electrical Troubleshooting

Access free engineering resources from IEE Business—covering power design, circuit layout, equipment selection, and troubleshooting. Expert-developed guides help engineers, procurement, and project teams make better decisions. Stay ahead on smart grids, renewables, efficiency, and AI tools. Improve reliability, reduce downtime, and enhance outcomes with real-world solutions. Explore our knowledge hub today.
What are the design and application aspects of the 10KV feeder automatic voltage regulator?
After the rural power grid renovation project, the rural distribution network has seen considerable improvement. However, due to constraints like terrain, landscape, and investment scale, the layout is not optimal. As a result, the power supply radius of some 10 kV transmission lines exceeds the reasonable range. With the changes of seasons and day and night, there are significant voltage fluctuations, leading to issues such as sub - standard power quality and relatively high line losses, which
06/19/2025
Consult
Tip
Consult
Tip
Prototype Development of 20 kV Single-Phase Distribution Transformer
1. Design of 20 kV Single - phase Distribution Transformer20 kV distribution systems usually adopt cable lines or mixed cable - overhead line networks, and the neutral point is mostly grounded through a small resistance. When a single - phase grounding occurs, there will be no problem that the phase voltage will rise by more than √3 times as in the case of a single - phase fault in a 10 kV system. Therefore, the single - phase distribution transformer of the 20 kV system can adopt the
06/17/2025
Consult
Tip
Consult
Tip
Single-Phase Transformer with High Lightning Impulse Withstand Capability
1 IntroductionTo ensure the safe operation of railways and reduce the risk of lightning damage to railway telecommunication control systems, the author has specially researched and designed a single - phase series transformer with a relatively high impulse voltage withstand level, with the model number D10 - 1.2 - 30/10. This transformer is equipped with an oil conservator and adopts a fully sealed structure (it can also be designed as a dry - type structure according to actual needs). This seri
06/17/2025
Consult
Tip
Consult
Tip
Thermal Optimization Design for Control Cabinets of Pad-Mounted Transformers in Offshore Wind Turbines
Global energy transition boosts offshore wind power, yet complex marine environments challenge turbine reliability. The heat - dissipation of pad - mounted transformer control cabinets (PMTCCs) is critical—undissipated heat causes component damage. Optimizing PMTCC heat dissipation improves turbine efficiency, but research mostly focuses on onshore wind farms, neglecting offshore ones. Thus, design PMTCCs for offshore conditions to enhance safety.1 PMTCC Heat - Dissipation Optimization
06/17/2025
Consult
Tip
Consult
Tip
Thermal Management Design for Pad-Mounted Transformers
During actual operation, pad - mounted transformers face typical heat - related problems: High - temp/high - load trips: Prone to tripping under sustained high - temperature, high - load conditions. Fan & thermostat failures: Long - term fan use causes malfunctions, damaging thermostats and blocking hot - air discharge, disrupting operation. Poor fan placement: Mounting fans on the cabinet top forces power - off maintenance/ replacement; this layout also traps heat, raising indoor temps to s
06/16/2025
Consult
Tip
Consult
Tip
Research on Reliability Enhancement Scheme Implementation for Modular Intelligent Prefabricated Substations
1 Implementation Strategies for the Scheme1.1 Deepen Survey and ResearchBefore constructing prefabricated cabin - type substations, it is necessary to conduct detailed surveys of local working conditions, clarify the construction scale and objectives, evaluate existing power facilities, plan projects, make up for infrastructure shortcomings, and adjust the construction rhythm. Meanwhile, control costs to avoid project suspension.1.2 Strengthen Structural ConstructionDuring promotion, multi - dim
06/13/2025
Consult
Tip
Consult
Tip
Comparative Analysis of 500 kV Prefabricated Substations vs. Conventional Substations
The secondary equipment area of conventional substations uses reinforced concrete or prefabricated steel structures, facing issues like long construction cycles, unreasonable functional zone design, strict environmental assessments, dust, noise, and disturbances. Primary and secondary equipment can only be installed after civil works and decoration, lowering construction efficiency.Prefabricated cabin substations integrate modularity, intelligence, and cost - effectiveness, boasting green, energ
06/13/2025
Consult
Tip
Consult
Tip
The design of the three-purpose grounding transformer
Underground Power Cable Transmission LinesDirect - buried power cable lines have large ground - distributed capacitance, causing high single - phase - to - ground short - circuit capacitive current. For 10 kV lines, if this current exceeds 10 A, arcs hardly self - extinguish, risking arc overvoltage and endangering line equipment. Arc extinction is thus necessary. With a Dyn - connected main transformer, an arc - suppression coil on the secondary neutral point suffices. For Yd - connected ones,
06/12/2025
Consult
Tip
Consult
Tip
Design Calculations for Neutral Grounding Schemes and Grounding Transformer Sizing in Utility-Scale Solar PV Plants
1 Classification of Neutral Grounding Methods for Solar Photovoltaic Power StationsInfluenced by differences in voltage levels and grid structures across regions, the neutral grounding methods of power systems are mainly categorized into non-effective grounding and effective grounding. Non-effective grounding includes neutral grounding via arc suppression coils and neutral ungrounded systems, while effective grounding comprises neutral solid grounding and neutral grounding via resistors. The sel
06/12/2025
Consult
Tip
Consult
Tip
Zero-Sequence Impedance Characterization of Dry-Type Grounding Transformer with ZN Connection
In a neutral-insulated three-phase power system, an earthing transformer provides an artificial neutral point, which can be solidly earthed or earthed via reactors/arc suppression coils. The ZNyn11 connection is typical, where zero-sequence magnetomotive forces in the inner/outer half-windings of the same core column cancel out, balancing fault currents in series windings and minimizing zero-sequence leakage flux/impedance.Zero-sequence impedance is critical: it determines fault current magnitud
06/12/2025
Consult
Tip
Consult
Tip
Send inquiry