Access free engineering resources from IEE Business—covering power design, circuit layout, equipment selection, and troubleshooting. Expert-developed guides help engineers, procurement, and project teams make better decisions. Stay ahead on smart grids, renewables, efficiency, and AI tools. Improve reliability, reduce downtime, and enhance outcomes with real-world solutions. Explore our knowledge hub today.
Fault Analysis and Remedial Strategies for Reclosers in Vietnam's 20kV Coastal Grid
1. IntroductionIn Vietnam's coastal regions, 20kV reclosers play a critical role in maintaining power supply reliability amid harsh environmental conditions. These devices, compliant with IEC 62271-111 and Vietnam's national standard TCVN, are frequently exposed to salt fog, high humidity, and typhoons, necessitating robust fault management strategies. This article explores typical malfunctions of IP67-rated reclosers in Vietnam and proposes integrated solutions to enhance grid resilience.2. Env
06/03/2025
Consult
Tip
Consult
Tip
What are the possible causes of faults for high-voltage disconnect switches?
High-voltage disconnect switches are widely used in thermal power plants and are one of the important devices to ensure the stable operation of the power system in thermal power plants. They are mainly composed of moving and static contact components, switch bases, transmission mechanisms, operating mechanisms, porcelain insulators and porcelain insulator bases. During the maintenance of electrical equipment, high-voltage disconnect switches can disconnect the electrical equipment from the power
05/29/2025
Consult
Tip
Consult
Tip
Intelligent Diagnosis and Analysis of Mechanical Failures in High-Voltage Isolating Switches
In modern power systems, high - voltage disconnect switches play a crucial role. They ensure the safe isolation of electrical equipment or lines during maintenance and the reliability during normal operation. Mechanical failures of high - voltage disconnect switches, such as poor contact, actuator failure, or structural component fatigue, can severely impact the stability and safety of the entire power system.Traditional fault - detection methods rely on regular maintenance and manual inspection
05/29/2025
Consult
Tip
Consult
Tip
Analysis and Countermeasures of a 145kV Disconnect Switch Maloperation Incident
1. IntroductionIn Indonesia's power grid, 145kV high voltage disconnect switches (HVDs) are critical for maintaining transmission reliability across its archipelagic terrain. However, maloperation incidents pose significant risks to grid stability. This article investigates a 145kV HVD maloperation in an Indonesian substation, analyzing root causes and proposing countermeasures while referencing IP66 protection standards and IEC 60068-3-3 compliance to enhance operational safety.2. Incident Over
05/29/2025
Consult
Tip
Consult
Tip
What requirements should be met for the maintenance of high-voltage disconnect switches?
Maintenance Requirements for High-Voltage Disconnect Switches in Indonesia: Focus on 72kV Systems with IP66 Protection1. IntroductionHigh-voltage disconnect switches (HVDs) are critical components in Indonesia's power grid, ensuring safe isolation of electrical equipment during maintenance and system operations. In a country characterized by tropical climates, high humidity, and diverse environmental conditions, maintaining 72kV HVDs with strict standards is paramount. This article outlines the
05/28/2025
Consult
Tip
Consult
Tip
Abnormal analysis and handling of 550 kV GIS Withstand Voltage test
Gas - insulated metal - enclosed switchgear (GIS) is a switching device composed of switching appliances such as circuit breakers (GCB), disconnectors (DS), earthing switches (ES), as well as units like voltage transformers, current transformers, surge arresters, and enclosed busbars. High - potential components are all placed inside a grounded enclosed metal shell, which is filled with SF₆ gas with excellent insulating and arc - extinguishing properties as the insulating medium. GIS features a
05/24/2025
Consult
Tip
Consult
Tip
Analysis of partial discharge of GIS busbars together
CIS (Gas Insulated Switchgear) refers to a gas - insulated enclosed switchgear assembly. A busbar is a common pathway to which multiple devices are connected in parallel. In a CIS, the internal space of the busbar is relatively small, yet it operates under high voltage and current. Local discharge, if it occurs, can severely affect the inter - phase insulation and pose a significant threat to the safe and stable operation of the equipment. This article presents an analysis and solution of a loca
05/24/2025
Consult
Tip
Consult
Tip
Analyze the discharge faults of pillar insulators based on multiple means
Overview of the SituationDuring the AC commissioning period of a certain substation, a flashover discharge fault of the post insulator occurred. The specific fault situation is as follows:When closing the 500 kV AC switchyard switch to charge the busbar, the dual - set busbar differential protection of the busbar operated, and the switch tripped. The fault phase was phase B, and the fault current was 5,760 A. The gas composition analysis of the SF₆ gas in the gas chamber was carried out, and the
05/24/2025
Consult
Tip
Consult
Tip
500kV SF₆ tank circuit breaker insulation pull rod discharge fault cause analysis and treatment
As a key component of circuit breakers, the insulating pull - rod is an important insulating and transmission part of Gas - Insulated Switchgear (GIS) equipment. It is required to have high reliability in terms of mechanical and electrical properties. Generally, insulating pull - rods rarely malfunction, but once a failure occurs, it can have serious consequences for the circuit breaker.The 550kV circuit breaker in a certain power station has a single - break horizontal arrangement, with the mod
05/21/2025
Consult
Tip
Consult
Tip
LW12-500 Dead tank Circuit Breakers Defect Analysis and Processing
IntroductionThe LW12 - 500 tank - type SF₆ circuit breaker is a domestic high - voltage circuit breaker. As the operation time increases continuously, frequent failures of the main body and operating mechanism have had a significant impact on the safe and stable operation of the power grid, affecting the power supply reliability and causing the maintenance cost of the circuit breaker to rise year by year. Aiming at the common defects and faults of the LW12 - 500 tank - type SF₆ circuit breaker,
05/20/2025
Consult
Tip
Consult
Tip