Access free engineering resources from IEE Business—covering power design, circuit layout, equipment selection, and troubleshooting. Expert-developed guides help engineers, procurement, and project teams make better decisions. Stay ahead on smart grids, renewables, efficiency, and AI tools. Improve reliability, reduce downtime, and enhance outcomes with real-world solutions. Explore our knowledge hub today.
How are core loss and hysteresis loss related?
Relationship Between Core Loss and Hysteresis LossCore loss (Core Loss) and hysteresis loss (Hysteresis Loss) are two common types of losses in electromagnetic devices. They are closely related but have distinct characteristics and mechanisms. Below is a detailed explanation of these two losses and their relationship:Core LossCore loss refers to the total energy loss that occurs within the core material due to the magnetization process in an alternating magnetic field. Core loss primarily consis
11/16/2024
Consult
Tip
Consult
Tip
FAQ About Lubrication Role in High Voltage Circuit Breakers
The Importance of LubricationIn high-voltage circuit breakers, lubrication plays a crucial role. Not only does lubrication affect the service life of the circuit breaker, but it also directly impacts its safety and reliability. Poor lubrication can lead to slow operation of the circuit breaker and even failure to function properly at critical moments, resulting in serious power system failures.Why is lubrication essential in the high-voltage circuit breaker operating mechanism?Lubrication in the
11/16/2024
Consult
Tip
Consult
Tip
What is the relationship between inductance and the number of turns in a coil?
What is the relationship between inductance and the number of turns in a coil?The inductance (Inductance) has a direct relationship with the number of turns (Number of Turns) in a coil. Specifically, the inductanceL is proportional to the square of the number of turns N. This relationship can be expressed by the following formula:where: L is the inductance (unit: Henry, H) N is the number of turns in the coil μ is the permeability (unit: Henry/meter, H/m) A is the cross-sectional area of the coi
11/15/2024
Consult
Tip
Consult
Tip
What are four major hazards which may arise from the use of electrical equipment?
The four major dangers associated with the use of electrical equipment mainly include the following:Electric Shock:Electric shock is one of the most common electrical hazards. When a person comes into contact with a live electrical part, current passes through the body, potentially causing anything from minor tingling to fatal injuries. Electric shocks not only pose a threat to personal safety but can also lead to equipment damage and production interruptions.Fire:Electrical equipment failures,
11/15/2024
Consult
Tip
Consult
Tip
What is the reason for the large and heavy size of microwave transformers?
The main reasons for the large size and heavy weight of microwave transformers include the following aspects:Frequency Characteristics:Microwave frequencies typically operate in the GHz range, much higher than the power frequency (such as 50Hz or 60Hz) used in traditional transformers. To function effectively at these high frequencies, microwave transformers require special materials and designs to reduce losses and improve efficiency. These specialized designs often lead to larger sizes.Core Ma
11/15/2024
Consult
Tip
Consult
Tip
LM1875 current feedback circuit
LM1875 current feedback circuit
Consult
Tip
Consult
Tip
What is the reason for high voltage power lines not being grounded on both ends?
The reason why high-voltage power lines are not grounded at both ends is primarily to prevent ground faults and ensure the safety and reliability of the electrical system. Here are some detailed reasons:Prevention of Ground Faults: If high-voltage lines were grounded at both ends, any insulation failure or accidental contact with the ground could cause a direct path for current to flow to earth, leading to a ground fault. This can result in significant damage to equipment and potential hazards t
11/15/2024
Consult
Tip
Consult
Tip
Differential amplifier circuit
Differential amplifier circuit
Consult
Tip
Consult
Tip
What are the potential problems that can arise when connecting an AC microgrid to a DC distribution system?
When connecting an AC microgrid to a DC distribution system, several potential issues may arise. Here's a detailed analysis of these problems:1. Power Quality Issues Voltage Fluctuations and Stability: Voltage fluctuations in AC microgrids can affect the stability of DC distribution systems. DC systems have higher requirements for voltage stability, and any fluctuations can lead to a decline in system performance or equipment damage. Harmonic Pollution: Nonlinear loads in AC microgrids can gener
11/15/2024
Consult
Tip
Consult
Tip
Circuit diagram of pipeline instrument
Circuit diagram of pipeline instrument
Consult
Tip
Consult
Tip