Free Expert Guides on Power Systems, Circuit Design & Electrical Troubleshooting

Access free engineering resources from IEE Business—covering power design, circuit layout, equipment selection, and troubleshooting. Expert-developed guides help engineers, procurement, and project teams make better decisions. Stay ahead on smart grids, renewables, efficiency, and AI tools. Improve reliability, reduce downtime, and enhance outcomes with real-world solutions. Explore our knowledge hub today.
Research on Detection Technology and Analysis Method of Partial Discharge in SF6 Floor Tank Circuit Breaker
The floor - mounted tank - type circuit breaker is a crucial control and protection device in substations and power systems. It is mainly used to interrupt, close, and carry normal load currents in lines, and to cut off short - circuit currents during system failures. Composed of components such as interrupting elements, insulating bushings, bushing - type current transformers, arc - extinguishing chambers, operating mechanisms, and grounding casings, the arc - extinguishing chamber of the floor
05/21/2025
Consult
Tip
Consult
Tip
What is Insulation Co-ordination?
Definition: Insulation coordination refers to the process of determining the insulation levels of power system components. In essence, it is about establishing the insulation strength of equipment. The internal and external insulation of electrical equipment is subjected to both continuous normal voltage and temporary abnormal voltage.Equipment insulation is engineered to withstand the highest power - frequency system voltage, occasional temporary power - frequency overvoltages, and occasional l
05/21/2025
Consult
Tip
Consult
Tip
Discussion on the Problem of Gas Liquefaction during the Installation of Tank Circuit Breakers in Severe Cold Regions
Technical Explanation of Sulfur Hexafluoride (SF₆) Circuit Breakers and Gas Liquefaction ChallengesSF₆ circuit breakers, which use sulfur hexafluoride gas—known for its excellent arc-quenching and insulating properties—as the arc-extinguishing medium, are widely applied in power systems. These breakers are suitable for frequent operations and scenarios requiring high-speed interruption. In China, SF₆ circuit breakers are basically used for voltage levels of 110kV and above. H
05/21/2025
Consult
Tip
Consult
Tip
Design and Application Case of 252kV Dead Tank SF6 Circuit Breaker Arc - Quenching Chamber System
IntroductionIn recent years, Nigeria's power demand has been on the rise with the development of its economy and society. A stable and reliable power transmission system is crucial for its development. The 252kV high - voltage transmission lines play an important role in Nigeria's power grid, and the performance of circuit breakers directly affects the safety and stability of these lines. ABB, as a world - leading electrical equipment manufacturer, has developed a 252kV dead tank SF6 circuit bre
05/21/2025
Consult
Tip
Consult
Tip
What is Sag Template?
Definition: A sag template is a tool used to accurately determine the positioning and height of supports on a profile. It defines the limits for vertical and wind loads, and also establishes minimum clearance angles between the sag and the ground for safety. Typically crafted from transparent materials such as celluloid or plexiglass (and occasionally cardboard), the sag template features the following marked curves: Hot Template Curve (Hot Curve) Ground Clearance Curve Support Foot or Tower Cur
05/21/2025
Consult
Tip
Consult
Tip
What is Phase & Phase Difference?
Definition: The phase of an alternating quantity represents the proportion of a complete cycle that the quantity has traversed relative to a designated reference origin. In the context of alternating electrical or physical phenomena, when two such quantities share identical frequencies, and their respective maxima (peaks) and minima (troughs) coincide precisely in time, these quantities are characterized as beingin phase. This synchronization indicates a perfect temporal alignment, where the wav
05/20/2025
Consult
Tip
Consult
Tip
Scheme Design of Three-phase Mechanical Transmission for 252kV Tank-type High-voltage sulfur Hexafluoride Circuit Breaker
Design and Application of Three-Phase Mechanical Linkage for 252kV Tank-Type SF₆ Circuit Breakers in China's High-Voltage Power GridIn China's high-voltage transmission network, three-phase power transmission systems are universally adopted, with high-voltage electrical equipment also configured in three-phase layouts. Most existing 252kV tank-type SF₆ circuit breakers feature phase-separated designs, where each phase is equipped with an independent motor-spring operating mechanism. Three-phase
05/20/2025
Consult
Tip
Consult
Tip
What is Biot Savart Law?
The Biot-Savart Law is employed to determine the magnetic field intensity dHnear a current-carrying conductor. In other words, it describes the relationship between the magnetic field intensity generated by a source current element. This law was formulated in 1820 by Jean-Baptiste Biot and Félix Savart. For a straight wire, the direction of the magnetic field adheres to the right-hand rule. The Biot-Savart Law is also referred to as Laplace’s law or Ampère&rsq
05/20/2025
Consult
Tip
Consult
Tip
LW12-500 Dead tank Circuit Breakers Defect Analysis and Processing
IntroductionThe LW12 - 500 tank - type SF₆ circuit breaker is a domestic high - voltage circuit breaker. As the operation time increases continuously, frequent failures of the main body and operating mechanism have had a significant impact on the safe and stable operation of the power grid, affecting the power supply reliability and causing the maintenance cost of the circuit breaker to rise year by year. Aiming at the common defects and faults of the LW12 - 500 tank - type SF₆ circuit breaker,
05/20/2025
Consult
Tip
Consult
Tip
Case study of tank SF₆ circuit breaker failure: African market from a Nigerian perspective
IntroductionIn the context of the African market, especially in Nigeria, the reliable operation of electrical equipment is of utmost importance for the stable development of the power industry. Tank - type SF₆ circuit breakers play a crucial role in power systems due to their excellent arc - extinguishing and insulating properties. However, like any electrical equipment, they are prone to failures. This paper presents a detailed case analysis of a tank - type SF₆ circuit breaker failure in Niger
05/20/2025
Consult
Tip
Consult
Tip