Free Expert Guides on Power Systems, Circuit Design & Electrical Troubleshooting

Access free engineering resources from IEE Business—covering power design, circuit layout, equipment selection, and troubleshooting. Expert-developed guides help engineers, procurement, and project teams make better decisions. Stay ahead on smart grids, renewables, efficiency, and AI tools. Improve reliability, reduce downtime, and enhance outcomes with real-world solutions. Explore our knowledge hub today.
Resistance Switching in a Circuit Breaker
Resistance SwitchingResistance switching refers to the practice of connecting a fixed resistor in parallel with the contact gap or arc of a circuit breaker. This technique is applied in circuit breakers with high post-arc resistance in the contact space, primarily to mitigate re-striking voltages and transient voltage surges.Severe voltage fluctuations in power systems arise from two main scenarios: interrupting low-magnitude inductive currents and breaking capacitive currents. Such overvoltages
05/23/2025
Consult
Tip
Consult
Tip
Circuit Breaker Ratings
The rating of a circuit breaker is determined by the duties it performs. For complete specifications, standard ratings and various tests for switches and circuit breakers should be consulted. In addition to the normal operation of circuit breakers, they are required to perform the following three major duties under short-circuit conditions: Breaking the faulty section of the system, defined as the breaking capacity of the circuit breaker. Making the circuit under the greatest asymmetrical curren
05/22/2025
Consult
Tip
Consult
Tip
Current Limiting Reactor
Current Limiting ReactorA current limiting reactor is an inductive coil characterized by a significantly higher inductive reactance compared to its resistance, designed to restrict short-circuit currents during fault conditions. These reactors also mitigate voltage disturbances in the remainder of the power system. They are installed in feeders, tie lines, generator leads, and between bus sections to reduce the magnitude of short-circuit currents and alleviate associated voltage fluctuations.Und
05/22/2025
Consult
Tip
Consult
Tip
Difference Between Soft Starter & VFD (Variable Frequency Drive)
Variable frequency drives (VFDs) and soft starters are distinct types of motor starting devices, though their use of semiconductor components often causes confusion. While both enable safe starting and stopping of induction motors, they differ significantly in operational principles, functionality, and application advantages.VFDs regulate both voltage and frequency to control motor speed dynamically, suitable for variable-load scenarios. Soft starters, however, use voltage ramping to limit inrus
05/22/2025
Consult
Tip
Consult
Tip
What is the function of the busbar in a switchgear, and how to select an appropriate busbar?
The role of busbars in switchgear:Busbars are conductors in switchgear that collect, distribute, and transmit electrical energy. They connect the power source (such as the output terminal of a transformer) to various branches (such as the incoming terminals of circuit breakers), acting as a transfer station for electrical energy. This enables electrical energy to be distributed to different electrical equipment or circuits as required.Methods for selecting appropriate busbars:Current - carrying
05/22/2025
Consult
Tip
Consult
Tip
Scott-T Transformer Connection
Definition: The Scott-T Connection is a technique for linking two single-phase transformers to enable 3-phase to 2-phase conversion and vice versa. The two transformers are electrically connected but operate independently magnetically. One transformer is designated as themain transformer, while the other is termed theauxiliaryorteaser transformer.The diagram below illustrates the Scott-T transformer connection: Themain transformerfeatures a center tap at pointDand is connected to linesBandCon th
05/22/2025
Consult
Tip
Consult
Tip
Effects of Electric Current on Human Body
When an electrical current traverses the human body, the nervous system endures an electric shock. The severity of this shock predominantly hinges on three key factors: the magnitude of the current, the pathway the current follows through the body, and the duration of contact. In the most severe instances, the shock disrupts the normal functioning of the heart and lungs, potentially leading to unconsciousness or even death.It is generally accepted that currents below 5 milliamperes (mA) pose min
05/22/2025
Consult
Tip
Consult
Tip
What is Automatic Voltage Regulator?
An automatic voltage regulator is employed to regulate voltage, converting fluctuating voltages into a constant one. Voltage fluctuations mainly stem from variations in the load on the supply system. Such voltage variations can damage the equipment within the power system. These fluctuations can be mitigated by installing voltage - control equipment at various locations, such as near transformers, generators, and feeders. Multiple voltage regulators are often placed throughout the power system t
05/22/2025
Consult
Tip
Consult
Tip
500kV SF₆ tank circuit breaker insulation pull rod discharge fault cause analysis and treatment
As a key component of circuit breakers, the insulating pull - rod is an important insulating and transmission part of Gas - Insulated Switchgear (GIS) equipment. It is required to have high reliability in terms of mechanical and electrical properties. Generally, insulating pull - rods rarely malfunction, but once a failure occurs, it can have serious consequences for the circuit breaker.The 550kV circuit breaker in a certain power station has a single - break horizontal arrangement, with the mod
05/21/2025
Consult
Tip
Consult
Tip
Research on the Application Mode and Operation Monitoring of Tank-type Circuit Breaker Heating Tapes in 500kV Substations in High-Cold Areas
At present, most low - voltage switchgear assemblies in China mainly use SF₆ gas at a pressure of 0.5 - 0.6 MPa as the insulating medium. However, when the ambient temperature drops to around - 32.5°C, the SF₆ gas will quickly liquefy, resulting in serious problems with the insulation and interrupting capabilities of the product. To avoid affecting the operation of low - voltage switchgear assemblies in alpine regions, tracing heaters are often used to prevent the liquefaction of SF₆ gas
05/21/2025
Consult
Tip
Consult
Tip