Free Expert Guides on Power Systems, Circuit Design & Electrical Troubleshooting

Access free engineering resources from IEE Business—covering power design, circuit layout, equipment selection, and troubleshooting. Expert-developed guides help engineers, procurement, and project teams make better decisions. Stay ahead on smart grids, renewables, efficiency, and AI tools. Improve reliability, reduce downtime, and enhance outcomes with real-world solutions. Explore our knowledge hub today.
Types of Faults in Power System
Power System Faults: Definition and ClassificationA fault in a power system is defined as an anomaly or defect that causes the electric current to deviate from its intended flow path. When a fault occurs, it creates abnormal operating conditions, primarily by reducing the insulation strength between conductors. This degradation of insulation can lead to severe damage to the power system components, disrupt normal power supply, and pose safety risks.Power system faults are primarily classified in
04/24/2025
Consult
Tip
Consult
Tip
Transposition of Conductors
DefinitionTransposition refers to the physical rotation of conductors, where each conductor is systematically shifted to occupy the next position in a predefined sequence. This process plays a crucial role in electrical systems by equalizing the mutual inductance and capacitance between lines. When conductors are irregularly spaced, it results in complex inductance values, which in turn complicates the analysis and study of power systems. Transposition is predominantly carried out in switching s
04/24/2025
Consult
Tip
Consult
Tip
Hot Wire Instrument
DefinitionA hot - wire instrument is defined as a type of measuring device that utilizes the heating effect of an electric current to determine the magnitude of that current. Its operation is based on the principle that when an electric current passes through a wire, the heat generated causes the wire to expand, increasing its length. This versatile instrument is capable of measuring both alternating current (AC) and direct current (DC), making it a valuable tool in various electrical applicatio
04/24/2025
Consult
Tip
Consult
Tip
Thermocouple Instrument
DefinitionA thermocouple instrument is defined as a measuring device that utilizes a thermocouple to determine temperature, current, and voltage. This versatile instrument is capable of making measurements in both alternating current (AC) and direct current (DC) circuits, making it a valuable tool across a wide range of applications.Thermocouple BasicsA thermocouple is an electrical device consisting of two wires made from different metals. Its functionality is based on a fundamental principle:
04/24/2025
Consult
Tip
Consult
Tip
What is a Resistance Box?
Resistance Box: Definition, Types, and OperationDefinitionA resistance box is a device that houses resistors of various values, primarily used for estimating and comparing electrical resistance. Renowned for its high accuracy, its main function is to regulate the precise amount of current flowing through an electrical circuit.AdvantagesOne of the key benefits of a resistance box is its ability to provide variable resistances in a single, centralized unit. In scenarios where a circuit demands var
04/24/2025
Consult
Tip
Consult
Tip
Generator circuit breaker (GCB) important special requirements
High Continuous Current LevelsGenerator Circuit Breakers (GCBs) are required to handle high continuous current levels over extended periods. To meet this demand, they necessitate a continuous cooling system for the conductors. This cooling mechanism ensures that the conductors can operate within a safe temperature range, preventing overheating and potential damage, thereby maintaining the reliability and efficiency of the GCBs during long - term high - current operations.Unique Fault Current Con
04/23/2025
Consult
Tip
Consult
Tip
Out of phase in generator circuit breaker (GCB)
An out-of-phase condition transpires when a generator circuit breaker (GCB) closing operation is executed precisely at the moment when there is a lack of synchronism between the voltage phasors of the generator on one side of the GCB and those of the external grid on the other side. Another common scenario is when a generator runs in an out-of-phase state due to system instability, necessitating the tripping of the GCB.The severity of such an interruption is directly related to the out-of-phase
04/22/2025
Consult
Tip
Consult
Tip
Generator circuit breaker (GCB) operating cycle in the gird
Generator circuit breakers are essentially suitable for a wide array of power generation plants, including fossil - fired, nuclear, gas turbine, combined - cycle, hydro, and pumped storage power plants. They are also ideal for retrofitting existing power stations that lack generator circuit breakers.Advantages of General Circuit Breakers (GCB) in the GridIn the past, generator circuit breakers were commonly used in multi - unit stations where several relatively small generators were linked to a
04/22/2025
Consult
Tip
Consult
Tip
Minor inspection list for gas insulated switchgear GIS
This inspection of GIS components can typically be carried out every 5 - 10 years. However, its frequency can also hinge on the number of operations of switching devices and the manufacturer's recommendations. The overarching aim is to verify the proper functioning of all switching devices. To this end, the relevant equipment must be de - energized.GIS manufacturers furnish users with recommended maintenance plans, which should be scrupulously adhered to. The typical operations during this inspe
04/21/2025
Consult
Tip
Consult
Tip
Typical alarms in gas insulated switchgear (GIS)
Gas Leak IndicationA gas density of approximately 90% or lower in each gas compartment and zone indicates the presence of a gas leak. This compromised gas density can gradually undermine the integrity of the insulation and operational performance of the equipment.Insulation Rating Non - ComplianceWhen the gas density drops to around 80% or less in every gas compartment and zone, it means that the dielectric ratings of the apparatus can no longer be maintained. This situation poses a significant
04/19/2025
Consult
Tip
Consult
Tip